EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Self Calibration of a 2 Wavelength Pyrometer

Download or read book Self Calibration of a 2 Wavelength Pyrometer written by National Aeronautics and Space Adm Nasa and published by Independently Published. This book was released on 2018-12-28 with total page 26 pages. Available in PDF, EPUB and Kindle. Book excerpt: Pyrometers require calibrations to determine their instrument constants before they can be used in remote temperature measurements. These constants reflect the combined effects of detector response, the transmissivities of intervening optical media (windows and gases) and the emissivity of the measured surface. We describe here the principal and the demonstration of self calibrating 2-wavelength pyrometer. Ng, Daniel Glenn Research Center NASA/TM-1998-208808, E-11398, NAS 1.15:208808 RTOP 523-21-13...

Book Self Calibration of a 2 wavelength Pyrometer

Download or read book Self Calibration of a 2 wavelength Pyrometer written by Daniel Ng and published by . This book was released on 1998 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book SELF CALIBRATION OF A 2 WAVELENGTH PYROMETER    NASA TM 1998 208808    JAN  20  1999

Download or read book SELF CALIBRATION OF A 2 WAVELENGTH PYROMETER NASA TM 1998 208808 JAN 20 1999 written by United States. National Aeronautics and Space Administration and published by . This book was released on 1999* with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Application of the Self Calibrating Emissivity And or Transmissivity Independent Multiwavelength Pyrometer in an Intense Ambient Radiation Environment

Download or read book Application of the Self Calibrating Emissivity And or Transmissivity Independent Multiwavelength Pyrometer in an Intense Ambient Radiation Environment written by and published by . This book was released on 1996 with total page 16 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Application of the Self Calibrating Emissivity And or Transmissivity Independent Multiwavelength Pyrometer to Measure the Temperatures of Tungsten and Refractory Material Surfaces

Download or read book Application of the Self Calibrating Emissivity And or Transmissivity Independent Multiwavelength Pyrometer to Measure the Temperatures of Tungsten and Refractory Material Surfaces written by and published by . This book was released on 1996 with total page 26 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Application of the Self Calibrating Emissivity And Or Transmissivity Independent Multiwavelength Pyrometer in an Intense Ambient Radiation Environment

Download or read book Application of the Self Calibrating Emissivity And Or Transmissivity Independent Multiwavelength Pyrometer in an Intense Ambient Radiation Environment written by National Aeronautics and Space Administration (NASA) and published by Createspace Independent Publishing Platform. This book was released on 2018-08-17 with total page 32 pages. Available in PDF, EPUB and Kindle. Book excerpt: The NASA self calibrating multiwavelength pyrometer is a recent addition to the list of pyrometers used in remote temperature measurement in research and development. The older one-color, two-color, and the disappearing filament pyrometers, as well as the multicolor and early multiwavelength pyrometers, all do not operate successfully in situations in which strong ambient radiation coexists with radiation originating from the measured surface. In such situations radiation departing from the target surface arrives at the pyrometer together with radiation coming from another source either directly or through reflection. Unlike the other pyrometers, the self calibrating multiwavelength pyrometer can still calibrate itself and measure the temperatures in this adverse environment. Ng, Daniel Glenn Research Center NASA-TM-107151, E-10089, NAS 1.15:107151 RTOP 505-62-50...

Book NASA Tech Briefs

Download or read book NASA Tech Briefs written by and published by . This book was released on 1997 with total page 636 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Remote Heat Flux Measurement Using a Self Calibration Multiwavelength Pyrometer and a Transparent Material

Download or read book Remote Heat Flux Measurement Using a Self Calibration Multiwavelength Pyrometer and a Transparent Material written by National Aeronautics and Space Adm Nasa and published by Independently Published. This book was released on 2018-12-29 with total page 28 pages. Available in PDF, EPUB and Kindle. Book excerpt: A self calibrating multiwavelength pyrometer was used to conduct remote heat flux measurements using a transparent sapphire disk by determining the sapphire disk's front and back surface temperatures. Front surface temperature (Tfs) was obtained from detection of surface emitted radiation at long wavelengths (lambda > 6 micrometers). Back surface temperature (Tbs) was obtained from short wavelength (1 to 5 micrometers) radiation transmitted through the sapphire disk. The thermal conductivity k of the sapphire disk and the heat transfer coefficients h(sub 1) and h(sub 2) of its surfaces are determined experimentally. An analysis of the heat flux measurement is presented. Ng, Daniel Glenn Research Center NASA/TM-1998-208809, NAS 1.15:208809, E-11399 RTOP 523-21-13...

Book Two Step Calibration of a Multiwavelength Pyrometer for High Temperature Measurement Using a Quartz Lamp

Download or read book Two Step Calibration of a Multiwavelength Pyrometer for High Temperature Measurement Using a Quartz Lamp written by National Aeronautics and Space Administration (NASA) and published by Createspace Independent Publishing Platform. This book was released on 2018-06-19 with total page 28 pages. Available in PDF, EPUB and Kindle. Book excerpt: There is no theoretical upper temperature limit for pyrometer application in temperature measurements. NASA Glenn's multiwavelength pyrometer can make measurements over wide temperature ranges. However, the radiation spectral response of the pyrometer's detector must be calibrated before any temperature measurement is attempted, and it is recommended that calibration be done at temperatures close to those for which measurements will be made. Calibration is a determination of the constants of proportionality at all wavelengths between the detector's output (voltage) and its input signals (usually from a blackbody radiation source) in order to convert detector output into radiation intensity. To measure high temperatures, the detectors are chosen to be sensitive in the spectral range from 0.4 to 2.5 micrometers. A blackbody furnace equilibrated at around 1000 C is often used for this calibration. Though the detector may respond sensitively to short wavelengths radiation, a blackbody furnace at 1000 C emits only feebly at very short wavelengths. As a consequence, the calibration constants that result may not be the most accurate. For pyrometry calibration, a radiation source emitting strongly at the short wavelengths is preferred. We have chosen a quartz halogen lamp for this purpose. Ng, Daniel Glenn Research Center NASA/TM-2001-211124, E-12973, NAS 1.15:211124

Book Handbook of Thermal Analysis and Calorimetry

Download or read book Handbook of Thermal Analysis and Calorimetry written by and published by Elsevier. This book was released on 2011-09-22 with total page 781 pages. Available in PDF, EPUB and Kindle. Book excerpt: This is Volume 5 of a Handbook that has been well-received by the thermal analysis and calorimetry community. All chapters in all five volumes are written by international experts in the subject. The fifth volume covers recent advances in techniques and applications that complement the earlier volumes. The chapters refer wherever possible to earlier volumes, but each is complete in itself. The latest recommendations on Nomenclature are also included. Amongst the important new techniques that are covered are micro-thermal analysis, pulsed thermal analysis, fast-scanning calorimetery and the use of quartz-crystal microbalances. There are detailed reviews of heating - stage spectroscopy, the range of electrical techniques available, applications in rheology, catalysis and the study of nanoparticles. The development and application of isoconversional methods of kinetic analysis are described and there are comprehensive chapters on the many facets of thermochemistry and of measuring thermophysical properties. Applications to inorganic and coordination chemistry are reviewed, as are the latest applications in medical and dental sciences, including the importance of polymorphism. The volume concludes with a review of the use and importance of thermal analysis and calorimetry in quality control. * Updates and complements previous volumes* Internationally recognized experts as authors * Each chapter complete in itself

Book Precision Measurement and Calibration

Download or read book Precision Measurement and Calibration written by J. F. Swindells and published by . This book was released on 1968 with total page 534 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Precision Measurement and Calibration  Temperature

Download or read book Precision Measurement and Calibration Temperature written by United States. National Bureau of Standards and published by . This book was released on 1969 with total page 536 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Practical Pyrometry

Download or read book Practical Pyrometry written by Ervin Sidney Ferry and published by . This book was released on 1917 with total page 168 pages. Available in PDF, EPUB and Kindle. Book excerpt: