EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Optimization of Dual Planar Laser Induced Fluorescence  DPLIF  Instrumentation for Characterization of Liquid Mixing in Sprays

Download or read book Optimization of Dual Planar Laser Induced Fluorescence DPLIF Instrumentation for Characterization of Liquid Mixing in Sprays written by Hannah Erin Bower and published by . This book was released on 2016 with total page 102 pages. Available in PDF, EPUB and Kindle. Book excerpt: In this effort, a novel Dual Planar Laser Induced Fluorescence (DPLIF) diagnostic is developed and optimized for characterizing the liquid-liquid interactions in rocket injector sprays. A critical attribute associated with the system is a desire to utilize relatively inexpensive components. The newly developed DPLIF diagnostic consists of a camera system, a laser system, and an optics system. The functionality and accuracy of the DPLIF system was determined through stationary liquid and dynamic spray experiments. The results, while preliminary, indicate that the DPLIF system can accurately represent the spatial interactions of two mixing liquids at the same time. Ultimately, the diagnostic shows promise for improved ability to more comprehensively characterize rocket injector sprays and, ultimately, improve rocket injector design.

Book Strategies for Planar Laser induced Fluorescence Thermometry in Shock Tube Flows

Download or read book Strategies for Planar Laser induced Fluorescence Thermometry in Shock Tube Flows written by Ji Hyung Yoo and published by Stanford University. This book was released on 2011 with total page 151 pages. Available in PDF, EPUB and Kindle. Book excerpt: This thesis was motivated by the need to better understand the temperature distribution in shock tube flows, especially in the near-wall flow regions. Two main ideas in planar laser-induced fluorescence (PLIF) diagnostics are explored in this thesis. The first topic is the development of a single-shot PLIF diagnostic technique for quantitative temperature distribution measurement in shock tube flow fields. PLIF is a non-intrusive, laser-based diagnostic technique capable of instantaneously imaging key flow features, such as temperature, pressure, density, and species concentration, by measuring fluorescence signal intensity from laser-excited tracer species. This study performed a comprehensive comparison of florescence tracers and excitation wavelengths to determine the optimal combination for PLIF imaging in shock tube flow applications. Excitation of toluene at 248nm wavelength was determined to be the optimal strategy due to the resulting high temperature sensitivity and fluorescence signal level, compared to other ketone and aromatic tracers at other excitation wavelengths. Sub-atmospheric toluene fluorescence yield data was measured to augment the existing photophysical data necessary for this diagnostic technique. In addition, a new imaging test section was built to allow PLIF imaging in all regions of the shock tube test section, including immediately adjacent to the side and end walls. The signal-to-noise (SNR) and spatial resolution of the PLIF images were optimized using statistical analysis. Temperature field measurements were made with the PLIF diagnostic technique across normal incident and reflected shocks in the shock tube core flow. The resulting images show uniform spatial distribution, and good agreement with conditions calculated from the normal shock jump equations. Temperature measurement uncertainty is about 3.6% at 800K. The diagnostic was also applied to image flow over a wedge. The resulting images capture all the flow features predicted by numerical simulations. The second topic is the development of a quantitative near-wall diagnostic using tracer-based PLIF imaging. Side wall thermal boundary layers and end wall thermal layers are imaged to study the temperature distribution present under constant pressure conditions. The diagnostic technique validated in the shock tube core flow region was further optimized to improve near-wall image quality. The optimization process considered various wall materials, laser sheet orientations, camera collection angles, and optical components to find the configuration that provides the best images. The resulting images have increased resolution (15[Mu]m) and are able to resolve very thin non-uniform near-wall temperature layers (down to 60[Mu]m from the surface). The temperature field and thickness measurements of near-wall shock tube flows under various shock conditions and test gases showed good agreement with boundary layer theory. To conclude this thesis, new applications and future improvements to the developed PLIF diagnostic technique are discussed. These suggested refinements can provide an even more robust and versatile PLIF imaging technique capable of measuring a wider range of flow conditions near walls.

Book Tracer based Planar Laser induced Fluorescence Diagnostics

Download or read book Tracer based Planar Laser induced Fluorescence Diagnostics written by Brian Ho-yin Cheung and published by Stanford University. This book was released on 2011 with total page 197 pages. Available in PDF, EPUB and Kindle. Book excerpt: Two advances to tracer-based planar laser-induced fluorescence (PLIF) diagnostics are presented in this work. The first improvement is the development of a 3-pentanone fluorescence quantum yield (FQY) database and model for a wide range of conditions in support of quantitative PLIF diagnostics. In addition, this work presents a sensitive, time-resolved tracer-based PLIF diagnostic, accomplished by using a continuous-wave (CW) laser with the high-FQY tracer toluene. Because of its ease of use and desirable photophysical properties, PLIF diagnostics using 3-pentanone as a tracer are common, particularly for internal combustion engine (ICE) diagnostics. Thus, there is a need for 3-pentanone FQY measurements and modeling over a wide range of temperatures, pressures, and excitation wavelengths. For insight into the collisionless process in the FQY model, measurements were made in 3-pentanone vapor at low-pressures across a range of temperatures using a flowing cell. Laser excitation with 248, 266, 277, 308 nm wavelengths were utilized, and Rayleigh scattering of the laser beam was used to calibrate the optical efficiency of the collection optics and detector. This low-pressure data allows calculation of the 3-pentanone fluorescence rate and non-radiative de-excitation rate in the fluorescence model. The vibrational relaxation cascade parameter for 3-pentanone collisions was also determined. Measurements of 3-pentanone FQY were also made over a range of temperatures and pressures relevant to diagnostic applications, and, in particular, combined high-temperature and high-pressure conditions applicable to internal combustion engines (ICE). These data were collected in a custom-built optical cell capable of simultaneous high-pressure and high-temperature conditions. The behavior of the FQY in nitrogen for temperatures up to 745 K and in air up to 570 K was examined for pressures from 1 to 25 bar. These data were used to further optimize the parameters in the FQY model representing collisional processes. The large quantity of data with 308 nm excitation allowed optimization of the nitrogen quenching rate, and data in air were used to optimize the oxygen quenching rate. These data were also used to optimize the vibrational relaxation parameters for nitrogen and oxygen. The model with the updated parameters is consistent with the data collected in the current work, as well as with fluorescence measurements made in optical ICEs up to 1100 K and 28 bar. Another area of tracer-based PLIF diagnostics development is time-resolved imaging. Because PLIF diagnostics are often performed using pulsed lasers, the time resolution of measurements is limited to the pulse rate of laser. Use of a high-powered visible laser with an off-the-shelf cavity frequency doubler is shown to produce a moderate-power CW beam in the ultraviolet wavelength regime. Application of this CW source to excite toluene, a high-FQY tracer, yields a sensitive, time-resolved tracer-based PLIF diagnostic. Fluctuation detection limits for tracer mole fraction were investigated by applying the diagnostic to an atmospheric temperature and pressure nitrogen jet seeded with 4% toluene, and detection limits of better than 1% of the maximum toluene mole fraction were achieved for detection of fluorescence signal at a point, along a line, and over a plane. The diagnostic was also demonstrated on a turbulent jet for line and planar detection and demonstrated the potential for toluene time-resolved PLIF diagnostics with CW lasers.

Book Commissioning a Commercial Laser Induced Fluorescence System for Characterization of Static Mixer Performance

Download or read book Commissioning a Commercial Laser Induced Fluorescence System for Characterization of Static Mixer Performance written by Madhumitha Ezhilan and published by . This book was released on 2017 with total page 49 pages. Available in PDF, EPUB and Kindle. Book excerpt: Turbulent mixing with a static mixer is studied using the Laser Induced Fluorescence (LIF) technique. In this study, a comparison of the blending effectiveness with and without the static mixer is drawn. The blending efficiency of the mixer is quantified by coefficient of variation (CoV), where a value of 0.05 signifies very good mixing. The lower the value of CoV, the better the blending quality. Two types of CoV, instantaneous and time-averaged, are determined to study the blending quality. For industrial purposes, the time-averaged CoV is typically used to characterize the mixing system. Data is collected at different Reynolds numbers and different distances from the point of injection of the dye. A commercial laser imaging software, DaVis, is used for the analysis of the data. The study shows that the software uses a different approach than what is expected to calculate the average instantaneous CoV which is incorrect and lower than the time-averaged CoV. A macro developed by Casselbury (2016) is adopted to calculate the average instantaneous CoV. Results show that mixing quality increased with increase in flow rate or mixing length. Also, the CoV values for tests with the static mixer are found to be lower than the empty pipeline which indicated that better mixing is achieved when the static mixer is used.

Book Strategies for Planar Laser induced Fluorescence Thermometry in Shock Tube Flows

Download or read book Strategies for Planar Laser induced Fluorescence Thermometry in Shock Tube Flows written by Ji Hyung Yoo and published by . This book was released on 2011 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This thesis was motivated by the need to better understand the temperature distribution in shock tube flows, especially in the near-wall flow regions. Two main ideas in planar laser-induced fluorescence (PLIF) diagnostics are explored in this thesis. The first topic is the development of a single-shot PLIF diagnostic technique for quantitative temperature distribution measurement in shock tube flow fields. PLIF is a non-intrusive, laser-based diagnostic technique capable of instantaneously imaging key flow features, such as temperature, pressure, density, and species concentration, by measuring fluorescence signal intensity from laser-excited tracer species. This study performed a comprehensive comparison of florescence tracers and excitation wavelengths to determine the optimal combination for PLIF imaging in shock tube flow applications. Excitation of toluene at 248nm wavelength was determined to be the optimal strategy due to the resulting high temperature sensitivity and fluorescence signal level, compared to other ketone and aromatic tracers at other excitation wavelengths. Sub-atmospheric toluene fluorescence yield data was measured to augment the existing photophysical data necessary for this diagnostic technique. In addition, a new imaging test section was built to allow PLIF imaging in all regions of the shock tube test section, including immediately adjacent to the side and end walls. The signal-to-noise (SNR) and spatial resolution of the PLIF images were optimized using statistical analysis. Temperature field measurements were made with the PLIF diagnostic technique across normal incident and reflected shocks in the shock tube core flow. The resulting images show uniform spatial distribution, and good agreement with conditions calculated from the normal shock jump equations. Temperature measurement uncertainty is about 3.6% at 800K. The diagnostic was also applied to image flow over a wedge. The resulting images capture all the flow features predicted by numerical simulations. The second topic is the development of a quantitative near-wall diagnostic using tracer-based PLIF imaging. Side wall thermal boundary layers and end wall thermal layers are imaged to study the temperature distribution present under constant pressure conditions. The diagnostic technique validated in the shock tube core flow region was further optimized to improve near-wall image quality. The optimization process considered various wall materials, laser sheet orientations, camera collection angles, and optical components to find the configuration that provides the best images. The resulting images have increased resolution (15[Mu]m) and are able to resolve very thin non-uniform near-wall temperature layers (down to 60[Mu]m from the surface). The temperature field and thickness measurements of near-wall shock tube flows under various shock conditions and test gases showed good agreement with boundary layer theory. To conclude this thesis, new applications and future improvements to the developed PLIF diagnostic technique are discussed. These suggested refinements can provide an even more robust and versatile PLIF imaging technique capable of measuring a wider range of flow conditions near walls.

Book Development and Optimisation of Two line Planar Laser Induced Fluorescence Technique for Combustion Measurements

Download or read book Development and Optimisation of Two line Planar Laser Induced Fluorescence Technique for Combustion Measurements written by Mohammadreza Anbari Attar and published by . This book was released on 2012 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This study has focused on development, optimisation and implementation of the 2-line Planar Laser Induced Fluorescence (2-line PLIF) technique for combustion measurements on a single cylinder optical Gasoline Direct Injection (GDI) engine with both Spark Ignition (SI) and Controlled Auto Ignition (CAI) combustion operations. The CAI combustion was achieved by employing Negative Valve Overlap (NVO). Two excitation wavelengths at 308 nm (directly from a XeCl laser) and 277 nm (via Raman shifting a KrF laser output at 248 nm) were exploited for the measurements. A calibration curve of fluorescence signal intensity ratio of the two laser beams as a function of temperature was obtained by conducting a series of static tests on a specially designed Constant Volume Chamber (CVC). The developed technique was validated by measurements of in-cylinder charge temperature during the compression stroke for both motoring and firing cycles and comparing the PLIF values with the temperature values calculated from in-cylinder pressure data assuming a polytropic compression. Following the validation measurements, the technique was applied to study of fuel spray characteristics and simultaneous measurements of in-cylinder charge temperature and mole fraction of Exhaust Gas Residuals (EGR). Further optimisation of the thermometry technique by enhancing the fluorescence Signal to Noise Ratio (SNR) and improving both the temporal and spatial resolutions as well as measurements precision provided the opportunity to apply the technique to other combustion measurements. The thesis presents the first application of the 2-line PLIF diagnostic in study of direct injection charge cooling effects and study of flame thermal stratification in IC engines.