EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Summary of Information on Flammable Gas Watch List Tanks

Download or read book Summary of Information on Flammable Gas Watch List Tanks written by H. R. Brager and published by . This book was released on 1994 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book

    Book Details:
  • Author :
  • Publisher :
  • Release : 1979
  • ISBN :
  • Pages : 271 pages

Download or read book written by and published by . This book was released on 1979 with total page 271 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Flammable Gas Tank Safety Program

Download or read book Flammable Gas Tank Safety Program written by and published by . This book was released on 1995 with total page 76 pages. Available in PDF, EPUB and Kindle. Book excerpt: Flammable gases generated in radioactive liquids. Twenty-five high level radioactive liquid waste storage tanks located underground at the Hanford Site are on a Flammable Gas Watch List because they contain waste which tends to retain the gases generated in it until rather large quantities are available for sudden release to the tank head space; if a tank is full it has little dome space, and a flammable concentration of gases could be produced--even if the tank is ventilated. If the waste has no tendency to retain gas generated in it then a continual flammable gas concentration in the tank dome space is established by the gas production rate and the tank ventilation rate (or breathing rate for unventilated tanks); this is also a potential problem for Flammable Gas Watch List tanks, and perhaps other Hanford tanks too. All Flammable Gas Watch List tanks will be fitted with Standard Hydorgen Monitoring Systems so that their behavior can be observed. In some cases, such as tank 241-SY-101, the data gathered from such observations will indicate that tank conditions need to be mitigated so that gas release events are either eliminated or rendered harmless. For example, a mixer pump was installed in tank 241-SY-101; operating the pump stirs the waste, replacing the large gas release events with small releases of gas that are kept below twenty-five percent of the lower flammability limit by the ventilation system. The concentration of hydrogen measured in Hanford waste tanks is greater than that of any other flammable gas. Hydrogen levels measured with a Standard Hydrogen Monitoring System in excess of 0.6 volume percent will cause Westinghouse Hanford Company to consider actions which will decrease the amount of flammable gas in the tank.

Book Recueil  Th    tre de Travers  1970 1971

Download or read book Recueil Th tre de Travers 1970 1971 written by and published by . This book was released on 1970 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book A Summary Description of the Flammable Gas Tank Safety Program

Download or read book A Summary Description of the Flammable Gas Tank Safety Program written by and published by . This book was released on 1994 with total page 124 pages. Available in PDF, EPUB and Kindle. Book excerpt: Radioactive liquid waste may produce hydrogen as result of the interaction of gamma radiation and water. If the waste contains organic chelating agents, additional hydrogen as well as nitrous oxide and ammonia may be produced by thermal and radiolytic decomposition of these organics. Several high-level radioactive liquid waste storage tanks, located underground at the Hanford Site in Washington State, are on a Flammable Gas Watch List. Some contain waste that produces and retains gases until large quantities of gas are released rapidly to the tank vapor space. Tanks nearly-filled to capacity have relatively little vapor space; therefore if the waste suddenly releases a large amount of hydrogen and nitrous oxide, a flammable gas mixture could result. The most notable example of a Hanford waste tank with a flammable gas problem is tank 241-SY-101. Upon occasion waste stored in this tank has released enough flammable gas to burn if an ignition source had been present inside of the tank. Several, other Hanford waste tanks exhibit similar behavior although to a lesser magnitude. Because this behavior was hot adequately-addressed in safety analysis reports for the Hanford Tank Farms, an unreviewed safety question was declared, and in 1990 the Flammable Gas Tank Safety Program was established to address this problem. The purposes of the program are a follows: (1) Provide safety documents to fill gaps in the safety analysis reports, and (2) Resolve the safety issue by acquiring knowledge about gas retention and release from radioactive liquid waste and developing mitigation technology. This document provides the general logic and work activities required to resolve the unreviewed safety question and the safety issue of flammable gas mixtures in radioactive liquid waste storage tanks.

Book Emergency Response Guidebook

Download or read book Emergency Response Guidebook written by U.S. Department of Transportation and published by Simon and Schuster. This book was released on 2013-06-03 with total page 352 pages. Available in PDF, EPUB and Kindle. Book excerpt: Does the identification number 60 indicate a toxic substance or a flammable solid, in the molten state at an elevated temperature? Does the identification number 1035 indicate ethane or butane? What is the difference between natural gas transmission pipelines and natural gas distribution pipelines? If you came upon an overturned truck on the highway that was leaking, would you be able to identify if it was hazardous and know what steps to take? Questions like these and more are answered in the Emergency Response Guidebook. Learn how to identify symbols for and vehicles carrying toxic, flammable, explosive, radioactive, or otherwise harmful substances and how to respond once an incident involving those substances has been identified. Always be prepared in situations that are unfamiliar and dangerous and know how to rectify them. Keeping this guide around at all times will ensure that, if you were to come upon a transportation situation involving hazardous substances or dangerous goods, you will be able to help keep others and yourself out of danger. With color-coded pages for quick and easy reference, this is the official manual used by first responders in the United States and Canada for transportation incidents involving dangerous goods or hazardous materials.

Book Radioactive Waste Management

Download or read book Radioactive Waste Management written by and published by . This book was released on 1981 with total page 726 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Flammable Gas Safety Program

Download or read book Flammable Gas Safety Program written by and published by . This book was released on 1995 with total page 34 pages. Available in PDF, EPUB and Kindle. Book excerpt: An analysis was performed to determine the optimum ventilation line up for the AN Tank Farm. The analysis used the postulated maximum historical GRE in tanks AN-103, -104, and -105. Tank AN-104 was found to be limiting. The results of the analysis show that an airflow of 250 cfm through tanks 241-AN-103, -104, and -105 with an airflow of 100 cfm through tanks 241-AN-101, -102, -106, and -107 would be the optimum ventilation lineup.

Book European Challenge  Geography and Develop

Download or read book European Challenge Geography and Develop written by and published by . This book was released on 1996 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Results of Vapor Space Monitoring of Flammable Gas Watch List Tanks

Download or read book Results of Vapor Space Monitoring of Flammable Gas Watch List Tanks written by and published by . This book was released on 2000 with total page 176 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report documents the measurement of headspace gas concentrations and monitoring results from the Hanford tanks that have continuous flammable gas monitoring. The systems used to monitor the tanks are Standard Hydrogen Monitoring Systems. Further characterization of the tank off-gases was done with Gas Characterization systems and vapor grab samples. The background concentrations of all tanks are below the action level of 6250 ppm. Other information which can be derived from the measurements (such as generation rate, released rate, and ventilation rate) is also discussed.

Book Strategy for Resolution of the Flammable Gas Safety Issue

Download or read book Strategy for Resolution of the Flammable Gas Safety Issue written by and published by . This book was released on 1995 with total page 35 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of this document is to provide the general strategy for resolution of the flammable gas safety issue; it is not a detailed description of program activities. budgets and schedules. Details of the program activities have been issued (Johnson and Sherwood, 1994) and the information pertaining to budgets is provided in the FY 1995-1997 Multi-Year Work Plan for Tank Waste Remediation System (TWRS) (Program Element 1.1.1.2.02.). The key element in this strategy is to provide an understanding of the behavior of each of the Flammable Gas Watch List tanks. While a review of historical information does provide some insight, it is necessary to gather current information about the gases, behavior and nature of the waste, . and about the control systems that maintain and monitor the waste. Analysis of this information will enable TWRS to determine the best approach to place any tank in a safe condition, if it is found to be in an unsafe state.

Book

    Book Details:
  • Author :
  • Publisher :
  • Release : 2002
  • ISBN : 9782724239805
  • Pages : 653 pages

Download or read book written by and published by . This book was released on 2002 with total page 653 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Energy Research Abstracts

Download or read book Energy Research Abstracts written by and published by . This book was released on 1995 with total page 782 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Flammable Gas Issues in Double contained Receiver Tanks  Revision 1

Download or read book Flammable Gas Issues in Double contained Receiver Tanks Revision 1 written by and published by . This book was released on 1998 with total page 170 pages. Available in PDF, EPUB and Kindle. Book excerpt: Four double-contained receiver tanks (DCRTs) at Hanford will be used to store salt-well pumped liquids from tanks on the Flammable Gas Watch List. This document was created to serve as a technical basis or reference document for flammable gas issues in DCRTs. The document identifies, describes, evaluates, and attempts to quantify potential gas carryover and release mechanisms. It estimates several key parameters needed for these calculations, such as initial aqueous concentrations and ventilation rate, and evaluates the uncertainty in those estimates. It justifies the use of the Schumpe model for estimating vapor-liquid equilibrium constants. It identifies several potential waste compatibility issues (such as mixing and pH or temperature changes) that could lead to gas release and provides a basis for calculating their effects. It evaluates the potential for gas retention in precipitated solids within a DCRT and whether retention could lead to a buoyant displacement instability (rollover) event. It discusses rates of radiolytic, thermal, and corrosive hydrogen generation within the DCRT. It also describes in detail the accepted method of calculating the lower flammability limit (LFL) for mixtures of flammable gases.

Book Safety Evaluation of Interim Stabilization of Non stabilized Single shell Watch List Tanks

Download or read book Safety Evaluation of Interim Stabilization of Non stabilized Single shell Watch List Tanks written by and published by . This book was released on 1994 with total page 101 pages. Available in PDF, EPUB and Kindle. Book excerpt: The report provides a summation of the status of safety issues associated with interim stabilization of Watch List SSTs (organic, ferrocyanide, and flammable gas), as extracted from recent safety analyses, including the Tank Farms Accelerated Safety Analysis efforts.