EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Spent Nuclear Fuel  SNF  Cold Vacuum Drying  CVD  Facility Operations Manual

Download or read book Spent Nuclear Fuel SNF Cold Vacuum Drying CVD Facility Operations Manual written by and published by . This book was released on 1999 with total page 97 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the Operations Manual for the Cold Vacuum Drying Facility (CVDF). The Manual was developed in conjunction with HNF-553, Spent Nuclear Fuel Project Final Safety Analysis Report Annex B--Cold Vacuum Drying Facility. The HNF-SD-SNF-DRD-002, 1999, Cold Vacuum Drying Facility Design Requirements, Rev. 4, and the CVDF Final Design Report. The Operations Manual contains general descriptions of all the process, safety and facility systems in the CVDF, a general CVD operations sequence and references to the CVDF System Design Descriptions (SDDs). This manual has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

Book A Budakeszi F  ldm  gneses Obszervat  rium megfigyel  sei

Download or read book A Budakeszi F ldm gneses Obszervat rium megfigyel sei written by and published by . This book was released on 1966 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Spent Nuclear Fuel  SNF  Project Cold Vacuum Drying  CVD  Facility Master Equipment List

Download or read book Spent Nuclear Fuel SNF Project Cold Vacuum Drying CVD Facility Master Equipment List written by and published by . This book was released on 1999 with total page 134 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the master equipment list (MEL) for the Cold Vacuum Drying Facility (CVDF). The MEL was prepared to comply with DOE Standard 3024-98, Content of System Design Descriptions. The MEL was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems and the CVDF System Design Descriptions (SDD). The MEL identifies the SSCs and their safety functions, the design criteria, codes and standards, and quality assurance requirements that are required for establishing the safety design basis of the SSCs. The MEL also includes operating parameters, manufacturer information, and references the procurement specifications for the SSCs. This MEL shall be updated, expanded, and revised in accordance with future phases of the CVDF SAR, the SDD's, and CVDF operations.

Book Spent Nuclear Fuel Project Cold Vacuum Drying Facility Supporting Data and Calculation Database

Download or read book Spent Nuclear Fuel Project Cold Vacuum Drying Facility Supporting Data and Calculation Database written by and published by . This book was released on 1999 with total page 17 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides a database of supporting calculations for the Cold Vacuum Drying Facility (CVDF). The database was developed in conjunction with HNF-SD-SNF-SAR-002, ''Safety Analysis Report for the Cold Vacuum Drying Facility'', Phase 2, ''Supporting Installation of Processing Systems'' (Garvin 1998). The HNF-SD-SNF-DRD-002, 1997, ''Cold Vacuum Drying Facility Design Requirements'', Rev. 2, and the CVDF Summary Design Report. The database contains calculation report entries for all process, safety and facility systems in the CVDF, a general CVD operations sequence and the CVDF System Design Descriptions (SDDs). This database has been developed for the SNFP CVDF Engineering Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

Book Thermal Analysis of Cold Vacuum Drying  CVD  of Spent Nuclear Fuel  SNF

Download or read book Thermal Analysis of Cold Vacuum Drying CVD of Spent Nuclear Fuel SNF written by and published by . This book was released on 2000 with total page 212 pages. Available in PDF, EPUB and Kindle. Book excerpt: The thermal analysis examined transient thermal and chemical behavior of the Multi-Canister Overpack (MCO) container for a broad range of cases that represent the Cold Vacuum Drying (CVD) processes. The cases were defined to consider both normal and off-normal operations at the CVD Facility for an MCO with N Reactor spent fuel. This analysis provides the basis for the MCO thermal behavior at the CVD Facility in support of the safety basis documentation.

Book Spent Nuclear Fuel Project Criteria Document    Cold Vacuum Drying Facility Phase 2 Safety Analysis Report

Download or read book Spent Nuclear Fuel Project Criteria Document Cold Vacuum Drying Facility Phase 2 Safety Analysis Report written by and published by . This book was released on 1998 with total page 32 pages. Available in PDF, EPUB and Kindle. Book excerpt: The criteria document provides the criteria and guidance for developing the SNF CVDF Phase 2 SAR. This SAR will support the US Department of Energy, Richland Operations Office decision to authorize the procurement, installation, and installation acceptance testing of the CVDF systems.

Book Cold Vacuum Drying  CVD  Facility Design Basis Accident Analysis Documentation

Download or read book Cold Vacuum Drying CVD Facility Design Basis Accident Analysis Documentation written by and published by . This book was released on 1999 with total page 400 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the detailed accident analysis to support HNF-3553, Annex B, Spent Nuclear Fuel Project Final Safety Analysis Report (FSAR), ''Cold Vacuum Drying Facility Final Safety Analysis Report.'' All assumptions, parameters, and models used to provide the analysis of the design basis accidents are documented to support the conclusions in the FSAR. The calculations in this document address the design basis accidents (DBAs) selected for analysis in HNF-3553, ''Spent Nuclear Fuel Project Final Safety Analysis Report'', Annex B, ''Cold Vacuum Drying Facility Final Safety Analysis Report.'' The objective is to determine the quantity of radioactive particulate available for release at any point during processing at the Cold Vacuum Drying Facility (CVDF) and to use that quantity to determine the amount of radioactive material released during the DBAs. The radioactive material released is used to determine dose consequences to receptors at four locations, and the dose consequences are compared with the appropriate evaluation guidelines and release limits to ascertain the need for preventive and mitigative controls.

Book Hanford Spent Nuclear Fuel Cold Vacuum Drying Test Specification and Test Plan

Download or read book Hanford Spent Nuclear Fuel Cold Vacuum Drying Test Specification and Test Plan written by and published by . This book was released on 1996 with total page 37 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the test plan and test specification for SNF cold vacuum drying proof of concept, CVD process equipment validation, and proof of performance testing.

Book Hanford Spent Nuclear Fuel Cold Vacuum Drying Process Equipment Skid Modification Work Plan

Download or read book Hanford Spent Nuclear Fuel Cold Vacuum Drying Process Equipment Skid Modification Work Plan written by and published by . This book was released on 1998 with total page 14 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the work plan for modifications to be made to the first article Process Equipment Skid for the Cold Vacuum Drying (CVD) process. The primary objective is to provide engineering configuration control for any modifications made to the Process Equipment Skid during proof of performance testing at the 306E Facility. Development Control procedures will be used to complete the design drawings and Procurement Specification W-441-Pl-FA. The Process Equipment Skid is a system for removing water and drying Spent Nuclear Fuel contained in Multi-Canister Overpacks. The skid contains the Vacuum Purge System and the Tempered Water System (VPS/TWS). The first article Process Equipment Skid, and subsequent production skids, will later be installed in the Cold Vacuum Drying Facility.

Book Hanford Spent Nuclear Fuel Cold Vacuum Drying Proof of Performance Test Procedure

Download or read book Hanford Spent Nuclear Fuel Cold Vacuum Drying Proof of Performance Test Procedure written by and published by . This book was released on 1998 with total page 102 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the test procedure for cold testing of the first article skids for the Cold Vacuum Drying (CVD) process at the Facility. The primary objective of this testing is to confirm design choices and provide data for the initial start-up parameters for the process. The current scope of testing in this document includes design verification, drying cycle determination equipment performance testing of the CVD process and MCC components, heat up and cool-down cycle determination, and thermal model validation.

Book Thermal Analysis of Cold Vacuum Drying of Spent Nuclear Fuel

Download or read book Thermal Analysis of Cold Vacuum Drying of Spent Nuclear Fuel written by and published by . This book was released on 1998 with total page 414 pages. Available in PDF, EPUB and Kindle. Book excerpt: The thermal analysis examined transient thermal and chemical behavior of the Multi canister Overpack (MCO) container for a broad range of cases that represent the Cold Vacuum Drying (CVD) processes. The cases were defined to consider both normal and off-normal operations at the CVD Facility for an MCO with Mark IV N, Reactor spent fuel in four fuel baskets and one scrap basket. This analysis provides the basis for the MCO thermal behavior at the CVD Facility for its Phase 2 Safety Analysis Report (revision 4).

Book Cold Vacuum Drying  CVD  Facility Sampling and Analysis Plan

Download or read book Cold Vacuum Drying CVD Facility Sampling and Analysis Plan written by and published by . This book was released on 2000 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Cold Vacuum Drying (CVD) Facility provides the required process systems, supporting equipment, and facilities needed for the conditioning of spent nuclear fuel (SNF) from the Hanford K-Basins prior to storage at the Canister Storage Building (CSB). The process water conditioning (PWC) system collects and treats the selected liquid effluent streams generated by the CVD process. The PWC system uses ion exchange modules (IXMs) and filtration to remove radioactive ions and particulate from CVD effluent streams. Water treated by the PWC is collected in a 5000-gallon storage tank prior to shipment to an on-site facility for additional treatment and disposal. The purpose of this sampling and analysis plan is to document the basis for achieving the following data quality objectives: (1) Measurement of the radionuclide content of the water transferred from the multi-canister overpack (MCO), vacuum purge system (VPS) condensate tank, MCO/Cask annulus and deionized water flushes to the PWC system receiver tanks. (2) Trending the radionuclide inventory of IXMs to assure that they do not exceed the limits prescribed in HNF-2760, Rev. 0-D, ''Safety Analysis Report for Packaging (Onsite) Ion Exchange Modules, '' and HNF-EP-0063 Rev. 5, ''Hanford Site Solid Waste Acceptance Criteria'' for Category 3, non-TRU, low level waste (LLW). (3) Determining the radionuclide content of the PWC system bulk water storage tank to assure that it meets the limits set forth in HNF-3 172, Rev. 0, ''Hanford Site Liquid Waste Acceptance Criteria, '' to permit transfer and disposal at the Effluent Treatment Facility (ETF) located at the 200 East Area.

Book Spent Nuclear Fuel Project Cold Vacuum Drying Facility Tempered Water and Tempered Water Cooling System Design Description

Download or read book Spent Nuclear Fuel Project Cold Vacuum Drying Facility Tempered Water and Tempered Water Cooling System Design Description written by and published by . This book was released on 1998 with total page 68 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the System Design Description (SDD) for the Cold Vacuum Drying Facility (CVDF) Tempered Water (TW) and Tempered Water Cooling (TWC) System . The SDD was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998), The HNF-SD-SNF-DRD-O02, 1998, Cold Vacuum Drying Facility Design Requirements, and the CVDF Design Summary Report. The SDD contains general descriptions of the TW and TWC equipment, the system functions, requirements and interfaces. The SDD provides references for design and fabrication details, operation sequences and maintenance. This SOD has been developed for the SNFP Operations Organization and shall be updated, expanded, and revised in accordance with future design, construction and startup phases of the CVDF until the CVDF final ORR is approved.

Book Cold Vacuum Drying  CVD  Facility Hazards Analysis Report

Download or read book Cold Vacuum Drying CVD Facility Hazards Analysis Report written by and published by . This book was released on 2003 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This report describes the methodology used in conducting the Cold Vacuum Drying Facility (CVDF) Hazard Analysis to support the CVDF Final Safety Analysis Report and documents the results. The hazard analysis was performed in accordance with DOE-STD-3009-94, ''Preparation Guide for US. Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports, '' and implements the requirements of DOE Order 5480.23, ''Nuclear Safety Analysis Reports.''

Book U S  Environmental Protection Agency Clear Air Act Notice of Construction for the Spent Nuclear Fuel Project   Cold Vaccum Drying Facility  Project W 441

Download or read book U S Environmental Protection Agency Clear Air Act Notice of Construction for the Spent Nuclear Fuel Project Cold Vaccum Drying Facility Project W 441 written by and published by . This book was released on 1996 with total page 65 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides information regarding the source and the estimated quantity of potential airborne radionuclide emissions resulting from the operation of the Cold Vacuum Drying (CVD) Facility. The construction of the CVD Facility is scheduled to commence on or about December 1996, and will be completed when the process begins operation. This document serves as a Notice of Construction (NOC) pursuant to the requirements of 40 Code of Federal Regulations (CFR) 61 for the CVD Facility. About 80 percent of the U.S. Department of Energy's spent nuclear fuel (SNF) inventory is stored under water in the Hanford Site K Basins. Spent nuclear fuel in the K West Basin is contained in closed canisters, while the SNF in the K East Basin is in open canisters, which allow release of corrosion products to the K East Basin water. Storage of the current inventory in the K Basins was originally intended to be on an as-needed basis to sustain operation of the N Reactor while the Plutonium-Uranium Extraction (PUREX) Plant was refurbished and restarted. The decision in December 1992 to deactivate the PURF-X Plant left approximately 2,100 MT (2,300 tons) of uranium as part of the N Reactor SNF in the K Basins with no means for near-term removal and processing. The CVD Facility will be constructed in the 100 Area northwest of the 190 K West Building, which is in close proximity to the K East and K West Basins (Figures 1 and 08572). The CVD Facility will consist of five processing bays, with four of the bays fully equipped with processing equipment and the fifth bay configured as an open spare bay. The CVD Facility will have a support area consisting of a control room, change rooms, and other functions required to support operations.

Book Fire Hazard Analysis for the Cold Vacuum Drying Facility  CVD  Facility

Download or read book Fire Hazard Analysis for the Cold Vacuum Drying Facility CVD Facility written by and published by . This book was released on 2000 with total page 346 pages. Available in PDF, EPUB and Kindle. Book excerpt: The CVDF is a nonreactor nuclear facility that will process the Spent Nuclear Fuels (SNF) presently stored in the 105-KE and 105-KW SNF storage basins. Multi-canister overpacks (MCOs) will be loaded (filled) with K Basin fuel transported to the CVDF. The MCOs will be processed at the CVDF to remove free water from the fuel cells (packages). Following processing at the CVDF, the MCOs will be transported to the CSB for interim storage until a long-term storage solution can be implemented. This operation is expected to start in November 2000. A Fire Hazard Analysis (FHA) is required for all new facilities and all nonreactor nuclear facilities, in accordance with U.S. Department of Energy (DOE) Order 5480.7A, Fire Protection. This FHA has been prepared in accordance with DOE 5480.7A and HNF-PRO-350, Fire Hazard Analysis Requirements. Additionally, requirements or criteria contained in DOE, Richland Operations Office (RL) RL Implementing Directive (RLID) 5480.7, Fire Protection, or other DOE documentation are cited, as applicable. This FHA comprehensively assesses the risk of fire at the CVDF to ascertain whether the specific objectives of DOE 5480.7A are met. These specific fire protection objectives are: (1) Minimize the potential for the occurrence of a fire. (2) Ensure that fire does not cause an onsite or offsite release of radiological and other hazardous material that will threaten the public health and safety or the environment. (3) Establish requirements that will provide an acceptable degree of life safety to DOE and contractor personnel and ensure that there are no undue hazards to the public from fire and its effects in DOE facilities. (4) Ensure that vital DOE programs will not suffer unacceptable delays as a result of fire and related perils. (5) Ensure that property damage from fire and related perils does not exceed an acceptable level. (6) Ensure that process control and safety systems are not damaged by fire or related perils. This FHA is based on the facility as constructed and with planned operation at the time of document preparation. Changes in facility planned and actual operation require that the identified fire risks associated with the CVDF be re-evaluated. Consequently, formal documentation and future revision of this FHA may be required.