EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Procedures for Handling and Analysis of Uranium Hexafluoride  Inspection  weighing  and sampling of uranium hexafluoride cylinders

Download or read book Procedures for Handling and Analysis of Uranium Hexafluoride Inspection weighing and sampling of uranium hexafluoride cylinders written by U.S. Atomic Energy Commission and published by . This book was released on 1972 with total page 48 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Sampling Uranium Hexafluoride

Download or read book Sampling Uranium Hexafluoride written by and published by . This book was released on 1965 with total page 11 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Procedures for Handling and Analysis of Uranium Hexafluoride  Analysis

Download or read book Procedures for Handling and Analysis of Uranium Hexafluoride Analysis written by U.S. Atomic Energy Commission and published by . This book was released on 1972 with total page 204 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Ultrasonic Thickness Sampling Plan for the Depleted Uranium Hexafluoride Program

Download or read book Ultrasonic Thickness Sampling Plan for the Depleted Uranium Hexafluoride Program written by and published by . This book was released on 1996 with total page 25 pages. Available in PDF, EPUB and Kindle. Book excerpt: The United States Department of Energy (DOE) currently manages depleted uranium hexafluoride that is stored in approximately 50,000 carbon steel cylinders located at three DOE sites. The disposition of any particular cylinder for storage, handling, and transfer is based on the condition of the cylinder, where condition is ultimately reflected by the minimum wall thickness of a cylinder. Currently, the wall thickness of a cylinder may be measured using either a hand-held ultrasonic transducers or an automated scanner. At the Portsmouth site, the cylinder program is currently committed to a sampling plan that requires sampling 10% of the cylinders moved during the cylinder relocation efforts. The purpose of this report is to present a statistically-based sampling plan to be considered for use within the three site cylinder management program. This plan is designed to meet the following objectives: (1) allow determination of the current condition of the cylinder populations within the accuracy and confidence specified by cylinder program management, and (2) be sufficient for the models to be used for modeling purposes. The first objective does not require modeling in the sense of making assumptions about the corrosion process for the populations involved. By avoiding such additional assumptions, this may result in stronger statements to be made about the populations in question. Assumptions must be made regarding corrosion of the cylinders through time. The second objective depends on the particular model used. In this report, two basic methods are used in determining sample sizes. The sample sizes are intended to be conservative because it may be that other models are developed for use within the Program.

Book Development of Solid Materials for UF6 Sampling

Download or read book Development of Solid Materials for UF6 Sampling written by and published by . This book was released on 2016 with total page 18 pages. Available in PDF, EPUB and Kindle. Book excerpt: A handheld implementation of the ABACC-developed Cristallini method, which captures uranium hexafluoride samples as an inert salt, was organized in FY17 and succeeded in demonstrating the handheld sampler concept with reactive hexafluoride gases. The Cristallini method relies on the use of a hydrated substrate to react the incoming hexafluoride resulting in the formation of a stable uranyl fluoride salt. The Cristallini method has been demonstrated as a facility modification installed near the sampling tap of a gas centrifuge enrichment plant. While very successful in reducing the hazards of uranium hexafluoride sample, the method still takes a considerable amount of time and can only be used in facilities where the apparatus has been installed; this arrangement generally prohibits the sampling of filled cylinders that have already exited the facility and have been deposited in the on-site tank storage yard. The handheld unit under development will allow the use of the Cristallini method at facilities that have not been converted as well as tanks in the storage yard. The handheld system utilizes an active vacuum system, rather than a passive vacuum system in the facility setup, to drive the uranium hexafluoride onto the adsorbing media. The handheld unit will be battery operated for fully autonomous operation and will include onboard pressure sensing and flushing capability. To date, the system concept of operations was demonstrated with tungsten hexafluoride that showed the active vacuum pump with multiple cartridges of adsorbing media was viable. Concurrently, the hardened prototype system was developed and tested; removable sample cartridges were developed (the only non-COTS component to date); and preparations were made for uranium tests and a domestic field test.

Book Sampling  Characterization  and Remote Sensing of Aerosols Formed in the Atmospheric Hydrolysis of Uranium Hexafluoride

Download or read book Sampling Characterization and Remote Sensing of Aerosols Formed in the Atmospheric Hydrolysis of Uranium Hexafluoride written by and published by . This book was released on 1984 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: When gaseous uranium hexafluoride (UF6) is released into the atmosphere, it rapidly reacts with ambient moisture to form an aerosol of uranyl fluoride (UO2F2) and hydrogen fluoride (HF). As part of our Safety Analysis program, we have performed several experimental releases of HF6 in contained volumes in order to investigate techniques for sampling and characterizing the aerosol materials. The aggregate particle morphology and size distribution have been found to be dependent upon several conditions, including the temperature of the UF6 at the time of its release, the relative humidity of the air into which it is released, and the elapsed time after the release. Aerosol composition and settling rate have been investigated using stationary samplers for the separate collection of UO2F2 and HF and via laser spectroscopic remote sensing (Mie scatter and infrared spectroscopy). 25 refs., 16 figs., 5 tabs.

Book The Self Diffusion Coefficient of Uranium Hexafluoride

Download or read book The Self Diffusion Coefficient of Uranium Hexafluoride written by Edward Purdy Ney and published by . This book was released on 1946 with total page 26 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Uranium Hexafluoride

Download or read book Uranium Hexafluoride written by R. DeWitt and published by . This book was released on 1960 with total page 166 pages. Available in PDF, EPUB and Kindle. Book excerpt: