EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book OPTIMISATION DU PROTOTYPE QUADRIPOLE PIEGE IONIQUE EN TANDEM ORTHOGONAL  COMPREHENSION DE L AUTO IONISATION APPLIQUEE A L ANALYSE D ORGANOPHOSPHORES ET EXPLORATION DES POTENTIALITES DE L EMPLOI DES IONS NEGATIFS

Download or read book OPTIMISATION DU PROTOTYPE QUADRIPOLE PIEGE IONIQUE EN TANDEM ORTHOGONAL COMPREHENSION DE L AUTO IONISATION APPLIQUEE A L ANALYSE D ORGANOPHOSPHORES ET EXPLORATION DES POTENTIALITES DE L EMPLOI DES IONS NEGATIFS written by VALERIE.. STEINER and published by . This book was released on 2000 with total page 419 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'IDENTIFICATION ET LA DETECTION DE COMPOSES ORGANOPHOSPHORES SONT DES SUJETS D'ACTUALITE, EN RAISON DE LEUR TOXICITE. PARMI LES SPECTROMETRES DE MASSE UTILISABLES, LE PIEGE IONIQUE QUADRIPOLAIRE PERMET DE REALISER DES EXPERIENCES EN MODE MS N ET D'ETUDIER DES REACTIONS ION/MOLECULE (RIM) EN PHASE GAZEUSE. IL EST DONC TOUT DESIGNE POUR L'IDENTIFICATION STRUCTURALE DE COMPOSES D'INTERET ENVIRONNEMENTAL. UN TANDEM QUADRIPOLE/PIEGE IONIQUE A INJECTION ORTHOGONALE (Q/ITMS) A ETE REALISE AU LABORATOIRE. LA DEVIATION A 90 O PERMET D'INJECTER LES IONS SANS NEUTRE PRECURSEUR, POUR ETUDIER DES RIM DE MANIERE SPECIFIQUE. LA SOURCE EXTERNE PERMET DE FORMER DES IONS NEGATIFS, QU'ON PEUT ENSUITE INJECTER DANS LE PIEGE. PERTURBATIONS PROVOQUEES PAR LES CHAMPS D'ORDRE SUPERIEUR (RESONANCES NON-LINEAIRES), FAIBLE EFFICACITE DE PIEGEAGE DES IONS ET DISSOCIATION A L'INJECTION SONT LES PREMIERS OBSTACLES RENCONTRES. IL FAUT PLUSIEURS ETAPES D'OPTIMISATION POUR DES ETUDES DE RIM REPRODUCTIBLES ET SENSIBLES. POUR MIEUX COMPRENDRE LE PROCESSUS D'AUTO-IONISATION OBSERVE DANS LE PIEGE CONVENTIONNEL, DIFFERENTS IONS FRAGMENTS FH + DE L'ION M + DU DIETHYLMETHYLPHOSPHONATE DEMP ONT ETE SELECTIONNES PUIS INJECTES DANS LE PIEGE POUR REAGIR AVEC LES MOLECULES DE DEMP. TOUT UN PANEL DE REACTIONS A ETE MIS EN EVIDENCE, COMME LA PROTONATION ET LA FORMATION D'IONS ADDUITS NON-COVALENTS OU COVALENTS (POUVANT SE DISSOCIER DE MANIERE SPECIFIQUE). D'AUTRES IONS (ISSUS DU TMS, DME) ONT ENSUITE ETE INJECTES POUR REAGIR AVEC LE DEMP. LA REACTIVITE DE DIVERS PHOSPHONATES EN MODE NEGATIF VIS A VIS DE NUCLEOPHILES APPORTE DES INFORMATIONS COMPLEMENTAIRES. DES EXPERIENCES ONT ETE REALISEES ENTRE DES ALCOOLATES ET LE DEMP. TOUTES FOURNISSENT UN ACCES A LA MASSE MOLECULAIRE DU COMPOSE (IONS M-H ). DANS CERTAINS CAS, ON OBSERVE LA COMPETITION AVEC LE PROCESSUS SPECIFIQUE DE SUBSTITUTION NUCLEOPHILE SUR L'ATOME DE PHOSPHORE, IL APPORTE UNE INFORMATION SUR LA NATURE DU GROUPE SUBSTITUE SUR CET ATOME.

Book ETUDE D IONS NEGATIFS SUR UN PIEGE IONIQUE QUADRIPOLAIRE A IONISATION INTERNE

Download or read book ETUDE D IONS NEGATIFS SUR UN PIEGE IONIQUE QUADRIPOLAIRE A IONISATION INTERNE written by SEBASTIEN.. GREGOIRE and published by . This book was released on 1997 with total page 249 pages. Available in PDF, EPUB and Kindle. Book excerpt: LE PIEGE IONIQUE QUADRIPOLAIRE CONSTITUE UN APPAREIL D'ANALYSE DE GRAND INTERET EN SPECTROMETRIE DE MASSE. POURTANT, DANS SA CONFIGURATION A IONISATION INTERNE (LES IONS SONT FORMES AU SEIN DU PIEGE), L'ETUDE DES IONS NEGATIFS EST DIFFICILE. L'OBJET DE CE TRAVAIL EST DE DETERMINER LES PROBLEMES RENCONTRES LORS D'ANALYSES EN MODE NEGATIF SUR UN PIEGE IONIQUE QUADRIPOLAIRE A IONISATION INTERNE. EN PREMIER LIEU, LA FORMATION DES IONS NEGATIFS, PAR CAPTURE ELECTRONIQUE, EST RESTREINTE EN RAISON DE LA FORTE ACCELERATION DES ELECTRONS PAR LE CHAMP QUADRIPOLAIRE, LIMITANT LE NOMBRE D'ELECTRONS D'ENERGIE THERMIQUE NECESSAIRE AU PROCESSUS DE CAPTURE ELECTRONIQUE. EN OUTRE, LE CONFINEMENT SIMULTANE DES IONS POSITIFS ET DES IONS NEGATIFS PERTURBE FORTEMENT LES SPECTRES DE MASSE ENREGISTRES. LE POTENTIEL DE CHARGE D'ESPACE QUI REGNE AU SEIN DU PIEGE (DU AUX CONDITIONS D'IONISATION NECESSAIRES A L'OBSERVATION D'IONS NEGATIFS) DESTABILISENT LES IONS POSITIFS DE HAUTS RAPPORTS M/Z, TANDIS QUE LES IONS NEGATIFS STABILISES SONT OBSERVES. DE PLUS, DES PERTES DE RESOLUTION ET DE DECALIBRATION PEUVENT SURVENIR, DANS CERTAINS CAS, POUR LES IONS NEGATIFS, LORSQUE CES DERNIERS SONT EJECTES EN PRESENCE D'IONS POSITIFS DE PLUS HAUTS RAPPORTS M/Z. ENFIN, LES INTERACTIONS ION/ION LIMITENT L'ABONDANCE DE IONS NEGATIFS AU SEIN DU PIEGE. LE DERNIER POINT PORTE SUR LA DETECTION SIMULTANEE DES IONS POSITIFS ET DES IONS NEGATIFS, QUI S'EXPLIQUENT PAR LA GRANDE ENERGIE CINETIQUE DES IONS EJECTES. LA COMPREHENSION DE TOUS CES PHENOMENES, DETECTION, FORMATION ET CONFINEMENT SIMULTANE, PERMETTRA DE PROPOSER DES SOLUTIONS POSSIBLES AUX PROBLEMES RENCONTRES POUR L'ETUDE DES IONS NEGATIFS DANS LES PIEGES IONIQUES QUADRIPOLAIRES A IONISATION INTERNE.