EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Neutron Dosimetry at Commercial Nuclear Plants

Download or read book Neutron Dosimetry at Commercial Nuclear Plants written by G. W. R. Endres and published by . This book was released on 1981 with total page 164 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Dosimetry at Commercial Nuclear Plants

Download or read book Neutron Dosimetry at Commercial Nuclear Plants written by F. M. Cummings and published by . This book was released on 1983 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Dosimetry at Commercial Nuclear Plants

Download or read book Neutron Dosimetry at Commercial Nuclear Plants written by and published by . This book was released on 1981 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Dosimetry at Commercial Nuclear Plants

Download or read book Neutron Dosimetry at Commercial Nuclear Plants written by F. M. Cummings and published by . This book was released on 1986 with total page 26 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Dosimetry at Commercial Nuclear Plants

Download or read book Neutron Dosimetry at Commercial Nuclear Plants written by L. W. Brackenbush and published by . This book was released on 1984 with total page 105 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Dosimetry at Commercial Nuclear Plants  Annual Report of Subtask D

Download or read book Neutron Dosimetry at Commercial Nuclear Plants Annual Report of Subtask D written by and published by . This book was released on 1984 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This study was designed to observe the feasibility of the use by NRC licensees of the tissue equivalent proportional counter (TEPC) system as a neutron monitoring instrument. Laboratory tissue equivalent proportional counters were irradiated using 252Cf sources at NBS and PNL and were irradiated inside containment of four operating nuclear power plants (two boiling water reactors and two pressurized water reactors). On the average, neutron dose-equivalent rates determined using the TEPC were 1.05 times the calculated dose-equivalent rates for the bare and moderated 252Cf sources and 0.86 times the dose-equivalent rates determined using the multispheres inside containment of nuclear power plants. Further, neutron dose equivalent rates determined using portable remmeters were an average of 1.71 times the dose equivalent determined using the multispheres inside the containment of nuclear power plants. It was observed that while electronic noise from temperature and vibrational effects inside containment prohibited an adequate measure of absorbed dose from gammas, the measurement of neutron absorbed dose was unaffected by these environmental parameters. It is recommended that for use inside containment at nuclear power plants: (1) the laboratory scale TEPC is the superior technique for accurate determination of neutron dose equivalent, (2) for remmeters similar to the one evaluated in this study, neutron dose equivalent response should be corrected to account for dependence of response on neutron energy or the remmeters should be calibrated using a moderated neutron source, and (3) at present, the TEPC should not be used to measure absorbed dose from gammas. Upon the advent of a proven miniaturized TEPC, this instrument may prove to be a desirable replacement for current portable neutron monitoring devices for the determination of dose equivalent inside containment of commercial nuclear power plants.

Book Reactor Dosimetry

Download or read book Reactor Dosimetry written by Harry Farrar and published by ASTM International. This book was released on 1989 with total page 792 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Dosimetry at Nuclear Power Plants with Light Water Reactors  LWR

Download or read book Neutron Dosimetry at Nuclear Power Plants with Light Water Reactors LWR written by B. Hofmann and published by . This book was released on 1989 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Dosimetry

    Book Details:
  • Author : John W. Baum
  • Publisher :
  • Release : 1955
  • ISBN :
  • Pages : 116 pages

Download or read book Neutron Dosimetry written by John W. Baum and published by . This book was released on 1955 with total page 116 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Correlation of Neutron Data Taken at Commercial Nuclear Sites

Download or read book Correlation of Neutron Data Taken at Commercial Nuclear Sites written by and published by . This book was released on 1983 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: In this report, data from neutron measurement and dosimetry studies performed by Pacific Northwest Laboratory, the Environmental Measurements Laboratory, and Rensselaer Polytechnic Institute are examined and compared. The purpose of this data correlation effort is to determine whether useful relationships exist between the actual neutron dose equivalent in a typical commercial nuclear power reactor and various measurement parameters, such as ratios of the response of 9-in. to 3-in. spheres, neutron/gamma ratios, albedo dosimeter response and neutron spectrometer readings. In most neutron radiation fields found in the reactors visited, the response of albedo dosimeters can be brought into reasonable agreement with dose equivalents measured with multispheres, tissue equivalent proportional counters (TEPCs) or remmeters. Because the responses of the remmeters, like the responses of albedo dosimeters, are energy dependent, it is preferable to correct the responses of the albedo dosimeters to agree with dose equivalents measured with either TEPCs or multispheres. If one of these laboratory systems has been used to measure neutron dose equivalents at a specific pressurized water reactor, a calculated average albedo dosimeter correction factor can be used for most locations at that reactor. However, if the measured 9-in. to 3-in. remmeter ratio is greater than 0.20, it is advisable to use a plot of 9-in. to 3-in. remmeter ratios versus albedo dosimeter correction factors to obtain an albedo dosimeter correction factor. Because 9-in. to 3-in. remmeter ratios at boiling water reactors are typically greater than 0.20, the latter approach applies to this type of reactor.

Book Nuclear Data Guide for Reactor Neutron Metrology

Download or read book Nuclear Data Guide for Reactor Neutron Metrology written by J.H. Baard and published by Springer Science & Business Media. This book was released on 1989-11-30 with total page 414 pages. Available in PDF, EPUB and Kindle. Book excerpt: 'The book is strongly recommended as a guide to all working schientists and engineers who are actively involved in reactor neutron dosimetry.' S. Ganesan in International Journal for Radiation Applied Intrumentation Part A, 41 (7) 1990

Book Correlation of Neutron Data Taken at Commercial Nuclear Sites

Download or read book Correlation of Neutron Data Taken at Commercial Nuclear Sites written by L. A. Rathbun and published by . This book was released on 1983 with total page 27 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book The Design and Construction of a D20 moderated 252 Cf Course for Calibrating Neutron Personnel Dosimeters Used at Nuclear Power Reactors

Download or read book The Design and Construction of a D20 moderated 252 Cf Course for Calibrating Neutron Personnel Dosimeters Used at Nuclear Power Reactors written by Robert B. Schwartz and published by . This book was released on 1980 with total page 36 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Retrospective Fast Neutron Dosimetry of Nuclear Power Plants by Means of Scraping Samples Using the 93Nb n n  93mNb Reaction

Download or read book Retrospective Fast Neutron Dosimetry of Nuclear Power Plants by Means of Scraping Samples Using the 93Nb n n 93mNb Reaction written by J. van Aarle and published by . This book was released on 2001 with total page 7 pages. Available in PDF, EPUB and Kindle. Book excerpt: Steel samples from a core component of a boiling water reactor have been investigated in order to determine the accumulated fast neutron fluence. The study was performed by means of the reaction 93Nb(n,n')93mNb. For this examination, the steel samples were taken after having been irradiated during normal operation for about 20 years. Starting with chemical separation methods, the specific activity of 93mNb in the steel samples was measured by a) inductively coupled plasma mass spectrometry, and b) total reflection X-ray fluorescence technique. From these results, the fast neutron fluence for neutron energies above 1 MeV were calculated. The fluence values determined using inductively coupled plasma mass spectrometry are in good agreement with earlier 54Mn measurements.

Book Measurement of Absorbed Dose of Neutrons  and of Mixtures of Neutrons and Gamma Rays

Download or read book Measurement of Absorbed Dose of Neutrons and of Mixtures of Neutrons and Gamma Rays written by National Committee on Radiation Protection and Measurements (U.S.) and published by . This book was released on 1961 with total page 96 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Spectra and Dose Equivalent Inside Nuclear Power Reactor Containment

Download or read book Neutron Spectra and Dose Equivalent Inside Nuclear Power Reactor Containment written by J. M. Aldrich and published by . This book was released on 1981 with total page 52 pages. Available in PDF, EPUB and Kindle. Book excerpt: