Download or read book National Dam Inspection Program Colonial Dam Number 3 NDI Number PA 00209 PennDER Number 26 22 Ohio River Basin Fayette County Pennsylvania Phase I Inspection Report written by James P. Hannan and published by . This book was released on 1980 with total page 116 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of the investigation is to make a determination on whether or not the dam constitutes a hazard to human life or property.
Download or read book National Dam Inspection Program Colonial Dam Number 1 NDI Number PA 00206 PennDER Number 26 12 Ohio River Basin Allen Run Fayette County Pennsylvania Phase I Inspection Report written by James P. Hannan and published by . This book was released on 1980 with total page 97 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a review of available design information, engineering analyses, and visual observations of conditions as they existed on the date of the field inspection, the general condition of the Colonial Dam No. 1 is considered to be fair. This assessment is based on visual observations and hydrologic calculations that indicated: (1) that the earth embankment is in good condition, (2) that the principal spillways are in poor physical condition and have 'inadequate' capacity but are not 'seriously inadequate', and (3) the existence of non-serious deficiencies which are considered correctable. The structure is classified as a 'small' size, 'high' hazard dam. Corps of Engineers guidelines recommend 1/2 to one times the Probable Maximum Flood (PMF) for 'small' size, 'high' hazard dam. Colonial No. 1 Dam's Spillway Design Flood is 1/2 the Probable Maximum Flood (PMF).
Download or read book Technical Abstract Bulletin written by and published by . This book was released on 1980 with total page 208 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book OHIO RIVER BASIN WASHWATER RUN FAYETTE COUNTY PENNSYLVANIA NDI NO PA 00209 PENN DER NO 26 22 COLONIAL DAM NO 3 REDSTONE WATER COMPANY PHASE 1 INSPECTION REPORT NATIONAL DAM INSPECTION PROGRAM written by United States. Army. Corps of Engineers. Baltimore District and published by . This book was released on 1980 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book National Dam Inspection Program Bradford City Number 3 Dam NDI PA 00025 PennDER Number 42 10 Ohio River Basin Marilla Brook McKean County Pennsylvania Phase I Inspection Report written by C. Y. Chen and published by . This book was released on 1979 with total page 80 pages. Available in PDF, EPUB and Kindle. Book excerpt: Bradford City No. 3 Dam consists of a diaphragm earthfill embankment approximately 47 feet high and 770 feet long. A core wall consisting of mortar and sandstone blocks was constructed in the center of the embankment. The core wall extends 25 feet into each hillside and approximately 9 feet below the original ground surface at the deepest point in the center of the valley. The visual inspections and review of engineering data, performed in November 1978 through February 1979, indicate no serious deficiencies in the embankment requiring emergency attention. The dam was found to be in good overall condition at the time of inspection. However, the inspection revealed certain items of maintenance and rehabilitation necessary for the dam. Hydraulic/hydrologic evaluations revealed that the spillway will not pass the Probable Maximum Flood (PMF) without overtopping the dam. The spillway is considered 'inadequate' because the analysis indicated the spillway will pass a maximum of 45 percent of the PMF before overtopping the dam, and failure of the dam is not likely to occur under 50 percent PMF conditions.
Download or read book National Dam Inspection Program Crabapple Dam NDI Number PA 00907 PennDER Number 26 32 Ohio River Basin Crabapple Run Fayette County Pennsylvania Phase I Inspection Report written by James P. Hannan and published by . This book was released on 1980 with total page 97 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a review of available design information and visual observations, the general condition of the Crabapple Dam is considered to be poor. Visual observations and hydrology calculations indicate: (1) A possible inadequate margin of safety against slope failure as indicated by slope irregularities and groundwater conditions; (2) 'Inadequate' discharge capacity of the Principal Spillway as determined by using HEC-1 Dam Safety Version computer program; and (3) The lack of accessible control facilities on the outlet works pipelines.
Download or read book National Dam Inspection Program Star Junction Number 2 Dam NDI Number PA 00212 PennDER Number 26 31 Ohio River Basin Fayette County Commonwealth of Pennsylvania Phase I Inspection Report written by James P. Hannan and published by . This book was released on 1980 with total page 78 pages. Available in PDF, EPUB and Kindle. Book excerpt: Star Junction No. 2 Dam consists of an earthfill embankment and masonry spillway on the left abutment. The dam has a crest length of 341 feet, a maximum height of 30 feet and a storage volume of 31 acre-feet at the spillway crest level. The dam is classified by Corps of Engineers guidelines to be a small size, high hazard structure. Star Junction No. 2 Dam's embankment is assessed to be in poor condition. This is based on visual observations of the non-uniform slope, wet zones and state inspection reports. The downstream control was observed to be damaged and probably is not operable. No control or mechanism was observed to permit upstream flow control. The principal spillway is assessed to be in very poor condition. This is based on visual observations of the weir wall and training dike retaining wall. Both structures are partially collapsed and badly deteriorated and safe performance is questionable in the event of long-term, high discharge conditions.
Download or read book National Dam Inspection Program Royal Reservoir Dam NDI Number PA 00220 PennDER Number 26 41 Ohio River Basin Rowes Run Fayette County Pennsylvania Phase I Inspection Report written by James P. Hannan and published by . This book was released on 1980 with total page 90 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a review of available design information and visual observations of conditions as they existed on the date of the field inspection, the general condition of the Royal Reservoir Dam is considered to be poor.
Download or read book Languedoc Roussillon written by and published by . This book was released on with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book National Dam Inspection Program Trax Farm Dam NDI Number PA 00131 PennDer Number 63 96 Ohio River Basin Tributary to Peters Creek Washington County Pennsylvania Phase I Inspection Report written by and published by . This book was released on 1981 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt: Trax Farm Dam is located across an unnamed tributary to Peters Creek in Peters Township, Washington County, Pennsylvania, approximately 2.5 miles northwest of Finleyville, Pennsulvania. Trax Farm Dam was constructed to provide a water supply for irrigation. Based upon the observed height of the dam and downstream floodplain conditions, Trax Farm Dam was assigned a 'high' hazard potential rating.
Download or read book National Dam Inspection Program Heritage Reservation Dam NDI I D Number PA 01142 PennDER I D Number 26 101 Ohio River Basin Little Sandy Creek Fayette County Pennsylvania Phase I Inspection Report written by and published by . This book was released on 1981 with total page 85 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a visual inspection, operational history, and available engineering data, Heritage Reservation Dam is considered to be in excellent condition. The size classification of the facility is intermediate and the hazard classification is considered to be high. In accordance with the recommended guidelines, the Spillway Design Flood (SDF) is considered to be the PMF (Probable Maximum Flood). Results of the hydrologic and hydraulic analysis indicate that the facility is capable of passing and/or storing the PMF without overtopping the dam or dike. Consequently, the spillway is considered adequate.
Download or read book National Dam Inspection Program Star Junction Number 1 Dam NDI Number PA 00198 PennDER Number 26 30 Ohio River Basin Washington Run Fayette County Pennsylvania Phase I Inspection Report written by William McCormick and published by . This book was released on 1980 with total page 104 pages. Available in PDF, EPUB and Kindle. Book excerpt: Star Junction No. 1 dam consists of an earthfill embankment and masonry spillway on the right abutment. The dam has a crest length of 545 feet, a maximum height of 35 feet and a storage volume of 149.3 acre-feet at the spillway crest level. The dam is classified by Corps of Engineers guidelines to be a small size, high hazard structure. Based on the visual observations and the data available, the dam is categorized as being in an unsafe, non-emergency condition. The visual inspection revealed that the masonry spillway on the right abutment has deteriorated to the extent that its structural integrity during extended, large discharge conditions, is questionable.
Download or read book National Dam Inspection Program Virgin Run Dam NDS I D Number PA 00196 PennDer I D Number 26 85 Ohio River Basin Virgin Run Fayette County Pennsylvania Phase I Inspection Report written by Bernard M. Mihalcin and published by . This book was released on 1979 with total page 85 pages. Available in PDF, EPUB and Kindle. Book excerpt: Base on a visual inspection, operational history, and available engineering data, the dam is considered to be in fair condition. The size classification of the facility is small and its hazard classification is considered to be high. In accordance with the recommended guidelines, the Spillway Design Flood (SDF) for the facility is the Probable Maximum Flood (PMF). Results of the hydrologic and hydraulic analysis indicate the facility will pass and/or store about 62 percent of the PMF prior to embankment overtopping. Consequently, the spillway is assessed as being inadequate, but not seriously inadequate. Deficiencies noted by the inspection team included heavy overgrowth across the downstream toe, a questionable structural and foundation design associated with the spillway, and an inadequate emergency warning system.
Download or read book National Dam Inspection Program Fairchance Reservoir Dam NDI Number PA 00208 PennDER Number 26 70 Ohio River Basin Fayette County Commonwealth of Pennsylvania Phase I Inspection Report written by James P. Hannan and published by . This book was released on 1980 with total page 96 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a review of available design information and visual observations of conditions as they existed on the date of the field inspection, the general condition of the Fairchance Reservoir Dam is considered to be fair. This classification id based on: (1) The visual observation of the seeps in the pond drain discharge channel; (2) The presence of growing and fallen trees on the embankment slope; (3) Outlet works pipes through the embankment that have no positive upstream flow controls; and (4) An inadequate spillway capacity. The structure is classified as a small size, high hazard dam for which the Corps of Engineers guidelines require a Spillway Design Flood (SDF). For the observed downstream conditions the Fairchance Reservoir Dam SDF is one half the Probable Maximum Flood (PMF). Spillway capacity is inadequate because the non-over-topping flood discharge capacity, as estimated using the HEC-1 computer program was found to be 4 percent of the PMF. The spillway is not seriously inadequate because failure of the structure would not significantly increase the flood stage and risk of loss life downstream.
Download or read book National Dam Inspection Program DAM Number 3 NDI Number Pa 510 Ohio River Basin Washington County Pennsylvania Phase I Inspection Report written by Bernard M. Mihalcin and published by . This book was released on 1978 with total page 64 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367 authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspection of dams throughout the United States. The purpose is to determine if the dam constitutes a hazard to human life or property.
Download or read book National Dam Inspection Program Gallo Dam NDS I D Number PA 00233 Pender I D Number 56 91 Ohio River Basin Beaverdam Run Somerset County Pennsylvania Phase I Inspection Report written by GAI CONSULTANTS INC MONROEVILLE PA. and published by . This book was released on 1979 with total page 91 pages. Available in PDF, EPUB and Kindle. Book excerpt: Gallo Dam is a 29-foot high earth embankment approximately 690 feet long (including spillway). The embankment is reportedly comprised of 3 sections which include an impervious core, a semi-pervious upstream section and a pervious downstream section. The facility is served by a chute channel spillway, with discharges controlled by a free overfall, concrete weir structure. The spillway is located near the right abutment, and has a crest length of 39 feet. In addition, the facility is equipped with a 18-inch diameter steel pipe encased in concrete used as a low level outlet as well as a 16-inch diameter steel siphon which was installed in 1973.
Download or read book National Dam Inspection Program Greenlick Run Dam NDI Number PA 355 Ohio River Basin Greenlick Run Fayette County Pennsylvania Phase I Inspection Report written by GAI CONSULTANTS INC MONROEVILLE PA. and published by . This book was released on 1978 with total page 76 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367, authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspection of dams throughout the United States. The purpose is to determine if the dam constitutes a hazard to human life or property.