EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Evaluation and Modification of Existing Prototype Dynamic Calibration System for Pressure Measuring Transducers  Volume 2  Operating Procedures

Download or read book Evaluation and Modification of Existing Prototype Dynamic Calibration System for Pressure Measuring Transducers Volume 2 Operating Procedures written by and published by . This book was released on 1963 with total page 34 pages. Available in PDF, EPUB and Kindle. Book excerpt: The equipment used in the Edwards AFB Dynamic Calibration Facility is described. The report explains the dynamic calibration procedure and gives detailed equipment operating instructions. A shock tube is used to excite the transducer under test. A flow diagram and detailed explanation of shock tube utilization is presented. The data recording system is diagrammed, in correct operating arrangement. In this group of equipment there are two blast velocity gages which are used to measure the velocity of the shock wave. These gages are placed in ports on top of the shock tube in the test section. The leads from the blast velocity gages are connected to a Berkeley time interval meter. The electrical pulse from either one or the other of the blast velocity gages is also used to trigger the oscilloscope sweep. A Polaroid camera is used to photograph the test transducers output on the scope screen. The Flying Spot Analog-to-Digital Converter reads the transducer response as re corded on a photographic transparency and converts the film record to digital form. The digital information is recorded on IBM cards and/or printed paper tape. Output data rate is 40 cards per minute when punching cards and a maximum of 300 points per minute otherwise.

Book Evaluation and Modification of Existing Prototype Dynamic Calibration System for Pressure Measuring Transducers  Volume 1  Technical Results

Download or read book Evaluation and Modification of Existing Prototype Dynamic Calibration System for Pressure Measuring Transducers Volume 1 Technical Results written by and published by . This book was released on 1963 with total page 79 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Technical Abstract Bulletin

Download or read book Technical Abstract Bulletin written by Defense Documentation Center (U.S.) and published by . This book was released on 1964 with total page 1148 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book EVALUATION AND MODIFICATION OF EXISTING PROTOTYPE DYNAMIC CALIBRATION SYSTEM FOR PRESSURE MEASURING TRANSDUCERS  VOLUME 3  COMPUTER PROGRAMS

Download or read book EVALUATION AND MODIFICATION OF EXISTING PROTOTYPE DYNAMIC CALIBRATION SYSTEM FOR PRESSURE MEASURING TRANSDUCERS VOLUME 3 COMPUTER PROGRAMS written by and published by . This book was released on 1963 with total page 31 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Transfer Function Approximation Program (TFAP) is an IBM 7909 FORTRAN program which will compute the approximate transfer function for any linear pressure transducer system from the system's time response to a step input. Input data to the program contains information which specifies test conditions, information which defines the data range and density for the approximation, and information which specifies the amplitude of the time response at each of a number of equally spaced sample points in the time domain. Primary output data from the program contains the amplitude and phase of the approximate transfer function for the transducer system at equally spaced points in the frequency domain. With minor modifications, the program is adaptable to any problem which requires the computation of a linear system's transfer function from its time response to a known input. The program has been tested with time response data for an analytically known two degree-of-freedom system excited by a step input. The results of these tests indicate that the accuracy of the approximate transfer function is determined by the data sampling frequency and the data range. For sampling frequencies greater than twenty times the highest frequency of interest and a data range which includes the time response out to a point at which the time response has reached 99% of its final value, the approximate transfer function was found to be within .5% of its known value.

Book U S  Government Research Reports

Download or read book U S Government Research Reports written by and published by . This book was released on 1963 with total page 188 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Keywords Index to U S  Government Technical Reports  permuted Title Index

Download or read book Keywords Index to U S Government Technical Reports permuted Title Index written by United States. Department of Commerce. Office of Technical Services and published by . This book was released on 1963 with total page 618 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Methods for the Dynamic Calibration of Pressure Transducers

Download or read book Methods for the Dynamic Calibration of Pressure Transducers written by Dresser Industries, inc. Dresser Electronics, Southwestern Industrial Electronics Division, Houston, Texas and published by . This book was released on 1963 with total page 122 pages. Available in PDF, EPUB and Kindle. Book excerpt: Accurate dynamic measurements of pressure are a necessity in the design and development of modern rocket engines.To ensure their accu * racy, precise calibration methods must be employed.The publication is designed to provide a single reference source in which to find, for a particular pressure transducer, the appropriate mathematical model, the mathematical and instrumental methods of analysis, the methods of calibration, and the specific methods for evaluation of test data from each method of calibration.

Book Bibliography of Scientific and Industrial Reports

Download or read book Bibliography of Scientific and Industrial Reports written by and published by . This book was released on 1963 with total page 1018 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Scientific and Technical Aerospace Reports

Download or read book Scientific and Technical Aerospace Reports written by and published by . This book was released on 1990 with total page 980 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Development of a Pressure Transducer Calibration System  Dynamic Pressure Response Caliber   Phase 2

Download or read book Development of a Pressure Transducer Calibration System Dynamic Pressure Response Caliber Phase 2 written by and published by . This book was released on 1991 with total page 53 pages. Available in PDF, EPUB and Kindle. Book excerpt: Current dynamic pressure calibrators are restricted in ultimate peak pressure, bandwidth, and accuracy; in fact, static calibrations are commonly performed for dynamic transducers. A dynamic transducer calibration system has been developed for the bandwidth of 2 to 2,500 Hz. Controlled pressure can be provided, in sine or random format, for a standard transducer and a test transducer. For the frequency bands of 2 to 150 Hz and 1,600 to 2,400 Hz, acoustic pressure levels up to 1.0 psi RMS can be attained. The development of this system demonstrated the application to acoustic-mechanical systems of a hybrid technique known as admittance modeling. (This technique combines experimentally derived test data with finite element model results.) The system can be used with a variety of dynamics transducers. (Author).

Book A New Dynamic Pressure Source for the Calibration of Pressure Transducers  Classic Reprint

Download or read book A New Dynamic Pressure Source for the Calibration of Pressure Transducers Classic Reprint written by Carol F. Vezzetti and published by Forgotten Books. This book was released on 2017-10-28 with total page 42 pages. Available in PDF, EPUB and Kindle. Book excerpt: Excerpt from A New Dynamic Pressure Source for the Calibration of Pressure Transducers Key words: calibration; dynamic; dynamic calibration; dynamic pressure; dynamic pressure source; liquid column; pressure; pressure source; pressure transducer; sinusoidal pressure; transducer. About the Publisher Forgotten Books publishes hundreds of thousands of rare and classic books. Find more at www.forgottenbooks.com This book is a reproduction of an important historical work. Forgotten Books uses state-of-the-art technology to digitally reconstruct the work, preserving the original format whilst repairing imperfections present in the aged copy. In rare cases, an imperfection in the original, such as a blemish or missing page, may be replicated in our edition. We do, however, repair the vast majority of imperfections successfully; any imperfections that remain are intentionally left to preserve the state of such historical works.

Book A Dynamic Pressure Source for the Calibration of Pressure Transducers

Download or read book A Dynamic Pressure Source for the Calibration of Pressure Transducers written by and published by . This book was released on 1976 with total page 40 pages. Available in PDF, EPUB and Kindle. Book excerpt: