EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Etude d  un plasma    couplage inductif  I  C  P    27 mhz  et application    l  analyse multi  l  mentaire par spectrom  trie d    mission d  ultra violet d    chantillons g  ologiques

Download or read book Etude d un plasma couplage inductif I C P 27 mhz et application l analyse multi l mentaire par spectrom trie d mission d ultra violet d chantillons g ologiques written by and published by . This book was released on 1984 with total page 194 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book ETUDE DES PERFORMANCES ANALYTIQUES D UN PLASMA A COUPLAGE INDUCTIF ICP OBSERVE AXIALEMENT EN SPECTROMETRIE D EMISSION

Download or read book ETUDE DES PERFORMANCES ANALYTIQUES D UN PLASMA A COUPLAGE INDUCTIF ICP OBSERVE AXIALEMENT EN SPECTROMETRIE D EMISSION written by CENDRINE.. DUBUISSON and published by . This book was released on 1998 with total page 293 pages. Available in PDF, EPUB and Kindle. Book excerpt: IL EXISTE UN BESOIN CONSTANT D'AMELIORER LES LIMITES DE DETECTION DES METHODES D'ANALYSE ELEMENTAIRE. L'OBSERVATION AXIALE DU PLASMA A ETE PROPOSEE AFIN D'AMELIORER LES LIMITES DE DETECTION DE LA SPECTROMETRIE D'EMISSION ICP, CEPENDANT SON APPORT REEL SUR LES PERFORMANCES ANALYTIQUES DE LA METHODE N'A PAS ENCORE ETE CLAIREMENT ETABLI. NOUS NOUS SOMMES PRINCIPALEMENT INTERESSES AUX LIMITES DE DETECTION ET AUX EFFETS DE MATRICE. L'EVALUATION D'UN NOUVEAU PROTOTYPE A VISEE AXIALE A EGALEMENT ETE REALISEE. NOUS AVONS MONTRE QUE LE FACTEUR D'AMELIORATION MOYEN DES LIMITES DE DETECTION EN VISEE AXIALE EST DE 3 A 4. CE FACTEUR PROVIENT A LA FOIS D'UNE AMELIORATION DU RAPPORT SIGNAL SUR FOND ET DE L'ECART-TYPE RELATIF DU FOND POUR DES CONDITIONS DE MESURE IDENTIQUES. LE PROTOTYPE A VISEE AXIALE QUE NOUS AVONS EVALUE PRESENTE DES LIMITES DE DETECTION PLUS BASSES QUE CELLES DETERMINEES SUR LES SYSTEMES COMMERCIAUX ACTUELS. L'UTILISATION D'UN NEBULISEUR ULTRASONIQUE A PERMIS D'ATTEINDRE DES VALEURS COMPARABLES A CELLES DE L'ICP-MS POUR CERTAINS ELEMENTS. PAR AILLEURS, NOUS AVONS MONTRE QUE LES EFFETS DE MATRICE PEUVENT ETRE MINIMISES EN VISEE AXIALE COMME EN VISEE LATERALE DANS CERTAINES CONDITIONS OPERATOIRES QUI CONDUISENT A UN TRANSFERT D'ENERGIE OPTIMAL ENTRE L'ECHANTILLON ET LE PLASMA. DANS CES CONDITIONS OPERATOIRES APPELEES CONDITIONS ROBUSTES, LA CONTRIBUTION DES PERTURBATIONS LIEES AUX PHENOMENES D'ATOMISATION ET D'EXCITATION DES ELEMENTS EN PRESENCE D'INTERFERENT EST ELIMINEE, L'EFFET RESIDUEL POUVANT ETRE ATTRIBUE A UNE PERTURBATION DU SYSTEME D'INTRODUCTION. IL A ETE MONTRE QUE L'IMPORTANCE DE CES EFFETS VARIE SELON LE NEBULISEUR ET LA CHAMBRE DE NEBULISATION UTILISES. LA CARACTERISATION DES AEROSOLS PRODUITS MONTRE UNE MODIFICATION DES AEROSOLS TERTIAIRES ET/OU PRIMAIRES EN PRESENCE D'INTERFERENT. CES MODIFICATIONS DEPENDENT A LA FOIS DU SYSTEME D'INTRODUCTION ET DES PROPRIETES PHYSIQUES DU LIQUIDE NEBULISE. PAR AILLEURS, NOUS AVONS MIS EN EVIDENCE LE ROLE IMPORTANT DE LA CHAMBRE DE NEBULISATION, DE NOMBREUSES PERTURBATIONS SE PRODUISANT LORS DES PROCESSUS DE FILTRAGE ET DE TRANSPORT DE L'AEROSOL. L'EFFET RESIDUEL OBSERVE EN PRESENCE D'INTERFERENT DANS LES CONDITIONS ROBUSTES A ETE CORRIGE PAR LA METHODE DE L'ETALONNAGE INTERNE. AINSI, L'UTILISATION D'UN SEUL ETALON INTERNE PERMET DE COMPENSER DE FACON EFFICACE UNE DIFFERENCE IMPORTANTE ENTRE LA MATRICE DES ECHANTILLONS ET DES ETALONS POUR TOUTES LES RAIES DANS LES DEUX MODES D'OBSERVATION.

Book DIAGNOSTIC DU PLASMA A COUPLAGE INDUCTIF  APPLICATION A L ANALYSE

Download or read book DIAGNOSTIC DU PLASMA A COUPLAGE INDUCTIF APPLICATION A L ANALYSE written by FLORENCE.. SCHAMBEL and published by . This book was released on 1992 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LA SPECTROSCOPIE D'EMISSION ATOMIQUE (AES), ET LA SPECTROMETRIE DE MASSE (MS), ASSOCIEE A UN PLASMA A COUPLAGE INDUCTIF (ICP) RESPECTIVEMENT COMME SOURCE LUMINEUSE ET COMME SOURCE D'ION SONT DES TECHNIQUES D'ANALYSE QUANTITATIVES DES ELEMENTS LES PLUS PERFORMANTES. AU COURS DES DIX DERNIERES ANNEES, LES INSTRUMENTS ICP ONT TROUVE LEUR UTILISATION DANS DES DOMAINES TOUJOURS PLUS NOUVEAUX, OU L'ANALYSE ELEMENTAIRE PAR ICP S'EST IMPOSEE. PARMI LES ANALYSES LES PLUS COURANTES ON PEUT CITER: LES ELEMENTS MAJEURS ET LES ELEMENTS TRACES DANS LES ALLIAGES, LES MINERAIS, LES ROCHES, OU LES SEDIMENTS. LES ELEMENTS CONSIDERES COMME TOXIQUES QUE CE SOIT POUR DES PROBLEMES D'ENVIRONNEMENT OU DANS LE DOMAINE AGROALIMENTAIRE. LA SPECTROSCOPIE D'EMISSION PERMET L'ANALYSE SIMULTANEE DE 70 ELEMENTS NOTAMMENT LES ELEMENTS DIFFICILEMENT EXCITABLES COMME P,S,B OU LES TERRES RARES. ELLE TEND A ETRE REMPLACEE PAR LA SPECTROMETRIE DE MASSE QUI PERMET LA DETERMINATION SIMULTANEE DE 75 ELEMENTS AVEC DE MEILLEURS LIMITES DE DETECTION ET UNE PLUS GRANDE RAPIDITE. LA DIFFERENCE S'EXPRIME SURTOUT QUAND IL S'AGIT SOIT D'ANALYSER DES ELEMENTS TELS QUE U, PT, SE, DONT LES LIMITES DE DETECTION SONT MEDIOCRES EN EMISSION ATOMIQUE; SOIT DE FAIRE DES DOSAGES DANS DES MATRICES TRES RICHES EN RAIES PROVOQUANT DES INTERFERENCES SPECTRALES TELLES U, W, CE, TERRES RARES OU ENCORE DANS LA COMBINAISON DE CES DEUX CAS

Book VALIDATION DU COUPLAGE PLASMA  ICP    SPECTROMETRIE DE MASSE POUR L ANALYSE INORGANIQUE  ELEMENTS TRACE  DE MATRICES ALIMENTAIRES D ORIGINE ANIMALE

Download or read book VALIDATION DU COUPLAGE PLASMA ICP SPECTROMETRIE DE MASSE POUR L ANALYSE INORGANIQUE ELEMENTS TRACE DE MATRICES ALIMENTAIRES D ORIGINE ANIMALE written by SYLVIE-ISABELLE.. EXCOFFIER and published by . This book was released on 1997 with total page 290 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'INTERET ACTUELLEMENT PORTE A L'ANALYSE INORGANIQUE DE MATRICES ALIMENTAIRES S'EXPLIQUE PAR LES PROPRIETES NUTRITIONNELLES ET/OU TOXIQUES DES ELEMENTS IMPLIQUES. MAIS LES METHODES D'ANALYSE CONVENTIONNELLES UTILISEES, PRINCIPALEMENT DIFFERENTES TECHNIQUES DE SPECTROMETRIE D'ABSORPTION ATOMIQUE, ONT COMME PRINCIPALE LIMITATION D'ETRE MONO-ELEMENTAIRES. LE COUPLAGE PLASMA - SPECTROMETRIE D'EMISSION ATOMIQUE (ICP-AES) PERMET L'ANALYSE MULTI-ELEMENTAIRE MAIS LES LIMITES DE DETECTION ALORS OBTENUES SONT TROP ELEVEES (DE L'ORDRE DU G/L) POUR CETTE APPLICATION. LE COUPLAGE PLASMA - SPECTROMETRIE DE MASSE, EN ASSOCIANT CAPACITE D'ANALYSE MULTI-ELEMENTAIRE ET FAIBLES LIMITES DE DETECTION (DE L'ORDRE DU NG/L), S'AVERE ETRE UN OUTIL EFFICACE DANS CE CHAMP D'APPLICATIONS SPECIFIQUE. TOUTEFOIS, CET AVANTAGE IMPOSE D'ETABLIR DES COMPROMIS DANS L'OPTIMISATION DE L'ICP-MS AFIN DE PERMETTRE LA DETERMINATION DU PLUS GRAND NOMBRE D'ELEMENTS DANS LES MEILLEURES CONDITIONS. LA PREMIERE ETAPE A ETE DE RECHERCHER SUR DES SOLUTIONS ETALONS UN COMPROMIS ACCEPTABLE POUR L'ENSEMBLE DES ANALYTES (AL, AS, CD, CO, CR, CU, FE, MN, MO, NI, PB, SB, SE, SN ET ZN), DISTRIBUES SUR LA TOTALITE DE LA GAMME DES MASSES (DE 27 A 208 UMA). NOUS AVONS ALORS ETUDIE, POUR DIFFERENTES OPTIMISATIONS, LEURS CARACTERISTIQUES ANALYTIQUES : LINEARITE, SENSIBILITE, REPETABILITE, DERIVE A LONG TERME ET SPECIFICITE DU SIGNAL ASSOCIE. MAIS LES ECHANTILLONS ANALYSES COURAMMENT AU LABORATOIRE DOIVENT SUBIR AU PREALABLE UNE ETAPE NECESSAIRE DE MINERALISATION, ET, A CE NIVEAU DE CONCENTRATION (PPB), LES CONTAMINATIONS SONT FREQUENTES. DANS UNE DEUXIEME ETAPE, NOUS AVONS DONC ETUDIE PAS A PAS LES SOURCES POSSIBLES DE CONTAMINATIONS : QUALITE DES REACTIFS, VAISSELLE UTILISEE... NOUS NOUS SOMMES ENSUITE INTERESSES AUX LIMITES DE DETECTION ET DE QUANTIFICATION (CV = 10%) DE CHAQUE ANALYTE, TANT D'UN POINT DE VUE THEORIQUE QUE PRATIQUE. FINALEMENT, L'ANALYSE D'ECHANTILLONS DE REFERENCE, APRES MINERALISATION PAR VOIE SECHE OU DIGESTION PAR MICRO-ONDES (SYSTEME OUVERT), VALIDE L'ICP-MS COMME METHODE MULTI-ELEMENTAIRE D'ANALYSE INORGANIQUE DE MATRICES ALIMENTAIRES. L'ETAPE DE PREPARATION DE L'ECHANTILLON RESTE NEANMOINS LE MAILLON FAIBLE DE LA CHAINE ANALYTIQUE ET SERAIT A DEVELOPPER DANS LE FUTUR.

Book ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D UN SPECTROMETRE D EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D ANALYSE ELEMENTAIRE

Download or read book ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D UN SPECTROMETRE D EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D ANALYSE ELEMENTAIRE written by MARTINE.. CARRE JOUINEAU and published by . This book was released on 1991 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LE PLASMA A COUPLAGE INDUCTIF (ICP) EST UNE SOURCE LARGEMENT UTILISEE EN ANALYSE ELEMENTAIRE PAR SPECTROMETRIE D'EMISSION OPTIQUE. UNE INSTALLATION COMMERCIALE TYPIQUE VA COMPRENDRE: LE PLASMA LUI-MEME, UN GENERATEUR QUI APPORTE L'ENERGIE, UN SYSTEME D'INTRODUCTION D'ECHANTILLON QUI PERMET D'INTRODUIRE LE LIQUIDE DANS LA DECHARGE, UN SYSTEME DE DETECTION OPTIQUE ET UNE CHAINE D'ACQUISITION DU SIGNAL. AFIN D'AMELIORER LE RAPPORT SIGNAL SUR BRUIT DU JY 38 PLUS, COMMERCIALISE PAR JOBIN YVON, NOUS AVONS ETUDIE LES PRINCIPALES CAUSES D'INSTABILITE DUES A CHAQUE PARTIE DE L'APPAREIL. DANS UN PREMIER TEMPS, NOUS AVONS OPTIMISE LES CONDITIONS DE SOURCE POUR OBTENIR LE PLASMA LE PLUS STABLE ET LE PLUS PERFORMANT POSSIBLE. POUR CELA, NOUS AVONS ETUDIE L'INFLUENCE DES DEBITS DE GAZ ET DE LA PUISSANCE DU GENERATEUR SUR LA STABILITE DE L'EMISSION. ENSUITE UNE ETUDE GRANULOMETRIQUE ET VELOCIMETRIQUE DE DIFFERENTS SYSTEMES D'INTRODUCTION D'ECHANTILLON NOUS A PERMIS D'OBSERVER LES MODIFICATIONS DE L'AEROSOL AU COURS DE SON TRANSPORT. POUR COMPLETER NOTRE ETUDE, NOUS AVONS TESTE L'INFLUENCE DE LA RESOLUTION DU MONOCHROMATEUR SUR LE RAPPORT SIGNAL SUR BRUIT. ENFIN, DANS LES CONDITIONS OPTIMALES, NOUS AVONS DETERMINE LES LIMITES DE DETECTION REELLES DE L'APPAREIL, DANS DES SOLUTIONS AQUEUSES ET DANS UNE SOLUTION DE TUNGSTENE A 10 G/L

Book Gravure de l InP par plasma chlor      couplage inductif

Download or read book Gravure de l InP par plasma chlor couplage inductif written by Bo Liu and published by . This book was released on 2007 with total page 164 pages. Available in PDF, EPUB and Kindle. Book excerpt: Dans le cadre d'une collaboration avec le laboratoire LEOM (laboratoire d'électronique, Optoélectronique et Microsystème) de l’Ecole Centrale de Lyon, nous avons mené une étude concernant la gravure de l’InP par plasma ICP chloré. Ce type de procédé est considéré comme une étape clef dans la réalisation des cristaux photoniques à base d’InP. Afin de mieux comprendre les mécanismes Dans le cadre d’une collaboration avec le laboratoire LEOM (Laboratoire d’Electronique, physiques et cinétiques de la décharge ICP et son effet sur les propriétés structurelles et géométriques du matériau gravé, nous avons étudié, dans un premier temps, les phénomènes électriques et de transport par plasma en utilisant une sonde de Langmuir et la spectroscopie d’émission. Ces études ont montré l’effet de certains paramètres machine comme la puissance RF du réacteur ICP et la pression du gaz sur les propriétés électriques et de transport d’espèces chargées en particulier les électrons dont la densité et la température électroniques jouent un rôle important dans la décharge plasma. C’est ainsi que les évolutions de la densité et la température électroniques en fonction de la puissance RF et la pression du gaz ont été étudiées pour deux type de gaz : le chlore pur et le mélange Cl2/Ar. D’autre part, des analyses de surfaces d’InP gravées ont été effectuées en utilisant l’XPS (X-ray Photoélectron Spectroscopie), l’AFM (Atomic Force Microscopie) et la spectroscopie Raman. Les résultats révèlent que, contrairement à la gravure de l’InP par plasma de CH4/H2 où les surfaces gravées sont plutôt appauvries en phosphore, la gravure d’InP par plasma chloré présente dans la plupart des cas un appauvrissement de surface en indium. En parallèle à cette étude expérimentale, nous avons développé un modèle cinétique pour deux types de plasma : un plasma de Cl2 et celui de Cl2/Ar. Ce modèle est basé sur une approche globale qui permet de calculer les densités moyennes et les flux d’espèces présentes dans la décharge en résolvant les équations de bilan de masse. L’ajout de l’équation de bilan de puissance et l’équation de neutralité permet la détermination d’une manière auto-cohérente de la densité et la température électroniques en fonctions des paramètres machine. Les résultats obtenus par le modèle cinétiques ont été comparés à ceux obtenus par l’expérience. Un bon accord a été observé dans le cas d’un plasma de chlore pur et celui de mélange Cl2/Ar.