EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Etude d  un plasma    couplage inductif  I  C  P    27 mhz  et application    l  analyse multi  l  mentaire par spectrom  trie d    mission d  ultra violet d    chantillons g  ologiques

Download or read book Etude d un plasma couplage inductif I C P 27 mhz et application l analyse multi l mentaire par spectrom trie d mission d ultra violet d chantillons g ologiques written by and published by . This book was released on 1984 with total page 194 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book ETUDE DES PERFORMANCES ANALYTIQUES D UN PLASMA A COUPLAGE INDUCTIF ICP OBSERVE AXIALEMENT EN SPECTROMETRIE D EMISSION

Download or read book ETUDE DES PERFORMANCES ANALYTIQUES D UN PLASMA A COUPLAGE INDUCTIF ICP OBSERVE AXIALEMENT EN SPECTROMETRIE D EMISSION written by CENDRINE.. DUBUISSON and published by . This book was released on 1998 with total page 293 pages. Available in PDF, EPUB and Kindle. Book excerpt: IL EXISTE UN BESOIN CONSTANT D'AMELIORER LES LIMITES DE DETECTION DES METHODES D'ANALYSE ELEMENTAIRE. L'OBSERVATION AXIALE DU PLASMA A ETE PROPOSEE AFIN D'AMELIORER LES LIMITES DE DETECTION DE LA SPECTROMETRIE D'EMISSION ICP, CEPENDANT SON APPORT REEL SUR LES PERFORMANCES ANALYTIQUES DE LA METHODE N'A PAS ENCORE ETE CLAIREMENT ETABLI. NOUS NOUS SOMMES PRINCIPALEMENT INTERESSES AUX LIMITES DE DETECTION ET AUX EFFETS DE MATRICE. L'EVALUATION D'UN NOUVEAU PROTOTYPE A VISEE AXIALE A EGALEMENT ETE REALISEE. NOUS AVONS MONTRE QUE LE FACTEUR D'AMELIORATION MOYEN DES LIMITES DE DETECTION EN VISEE AXIALE EST DE 3 A 4. CE FACTEUR PROVIENT A LA FOIS D'UNE AMELIORATION DU RAPPORT SIGNAL SUR FOND ET DE L'ECART-TYPE RELATIF DU FOND POUR DES CONDITIONS DE MESURE IDENTIQUES. LE PROTOTYPE A VISEE AXIALE QUE NOUS AVONS EVALUE PRESENTE DES LIMITES DE DETECTION PLUS BASSES QUE CELLES DETERMINEES SUR LES SYSTEMES COMMERCIAUX ACTUELS. L'UTILISATION D'UN NEBULISEUR ULTRASONIQUE A PERMIS D'ATTEINDRE DES VALEURS COMPARABLES A CELLES DE L'ICP-MS POUR CERTAINS ELEMENTS. PAR AILLEURS, NOUS AVONS MONTRE QUE LES EFFETS DE MATRICE PEUVENT ETRE MINIMISES EN VISEE AXIALE COMME EN VISEE LATERALE DANS CERTAINES CONDITIONS OPERATOIRES QUI CONDUISENT A UN TRANSFERT D'ENERGIE OPTIMAL ENTRE L'ECHANTILLON ET LE PLASMA. DANS CES CONDITIONS OPERATOIRES APPELEES CONDITIONS ROBUSTES, LA CONTRIBUTION DES PERTURBATIONS LIEES AUX PHENOMENES D'ATOMISATION ET D'EXCITATION DES ELEMENTS EN PRESENCE D'INTERFERENT EST ELIMINEE, L'EFFET RESIDUEL POUVANT ETRE ATTRIBUE A UNE PERTURBATION DU SYSTEME D'INTRODUCTION. IL A ETE MONTRE QUE L'IMPORTANCE DE CES EFFETS VARIE SELON LE NEBULISEUR ET LA CHAMBRE DE NEBULISATION UTILISES. LA CARACTERISATION DES AEROSOLS PRODUITS MONTRE UNE MODIFICATION DES AEROSOLS TERTIAIRES ET/OU PRIMAIRES EN PRESENCE D'INTERFERENT. CES MODIFICATIONS DEPENDENT A LA FOIS DU SYSTEME D'INTRODUCTION ET DES PROPRIETES PHYSIQUES DU LIQUIDE NEBULISE. PAR AILLEURS, NOUS AVONS MIS EN EVIDENCE LE ROLE IMPORTANT DE LA CHAMBRE DE NEBULISATION, DE NOMBREUSES PERTURBATIONS SE PRODUISANT LORS DES PROCESSUS DE FILTRAGE ET DE TRANSPORT DE L'AEROSOL. L'EFFET RESIDUEL OBSERVE EN PRESENCE D'INTERFERENT DANS LES CONDITIONS ROBUSTES A ETE CORRIGE PAR LA METHODE DE L'ETALONNAGE INTERNE. AINSI, L'UTILISATION D'UN SEUL ETALON INTERNE PERMET DE COMPENSER DE FACON EFFICACE UNE DIFFERENCE IMPORTANTE ENTRE LA MATRICE DES ECHANTILLONS ET DES ETALONS POUR TOUTES LES RAIES DANS LES DEUX MODES D'OBSERVATION.

Book DIAGNOSTIC DU PLASMA A COUPLAGE INDUCTIF  APPLICATION A L ANALYSE

Download or read book DIAGNOSTIC DU PLASMA A COUPLAGE INDUCTIF APPLICATION A L ANALYSE written by FLORENCE.. SCHAMBEL and published by . This book was released on 1992 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LA SPECTROSCOPIE D'EMISSION ATOMIQUE (AES), ET LA SPECTROMETRIE DE MASSE (MS), ASSOCIEE A UN PLASMA A COUPLAGE INDUCTIF (ICP) RESPECTIVEMENT COMME SOURCE LUMINEUSE ET COMME SOURCE D'ION SONT DES TECHNIQUES D'ANALYSE QUANTITATIVES DES ELEMENTS LES PLUS PERFORMANTES. AU COURS DES DIX DERNIERES ANNEES, LES INSTRUMENTS ICP ONT TROUVE LEUR UTILISATION DANS DES DOMAINES TOUJOURS PLUS NOUVEAUX, OU L'ANALYSE ELEMENTAIRE PAR ICP S'EST IMPOSEE. PARMI LES ANALYSES LES PLUS COURANTES ON PEUT CITER: LES ELEMENTS MAJEURS ET LES ELEMENTS TRACES DANS LES ALLIAGES, LES MINERAIS, LES ROCHES, OU LES SEDIMENTS. LES ELEMENTS CONSIDERES COMME TOXIQUES QUE CE SOIT POUR DES PROBLEMES D'ENVIRONNEMENT OU DANS LE DOMAINE AGROALIMENTAIRE. LA SPECTROSCOPIE D'EMISSION PERMET L'ANALYSE SIMULTANEE DE 70 ELEMENTS NOTAMMENT LES ELEMENTS DIFFICILEMENT EXCITABLES COMME P,S,B OU LES TERRES RARES. ELLE TEND A ETRE REMPLACEE PAR LA SPECTROMETRIE DE MASSE QUI PERMET LA DETERMINATION SIMULTANEE DE 75 ELEMENTS AVEC DE MEILLEURS LIMITES DE DETECTION ET UNE PLUS GRANDE RAPIDITE. LA DIFFERENCE S'EXPRIME SURTOUT QUAND IL S'AGIT SOIT D'ANALYSER DES ELEMENTS TELS QUE U, PT, SE, DONT LES LIMITES DE DETECTION SONT MEDIOCRES EN EMISSION ATOMIQUE; SOIT DE FAIRE DES DOSAGES DANS DES MATRICES TRES RICHES EN RAIES PROVOQUANT DES INTERFERENCES SPECTRALES TELLES U, W, CE, TERRES RARES OU ENCORE DANS LA COMBINAISON DE CES DEUX CAS

Book ETUDE ET DEVELOPPEMENT DU COUPLAGE ABLATION LASER   SPECTROMETRIE PLASMA  ICP  POUR L ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DANS LES MATIERES PLASTIQUES

Download or read book ETUDE ET DEVELOPPEMENT DU COUPLAGE ABLATION LASER SPECTROMETRIE PLASMA ICP POUR L ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DANS LES MATIERES PLASTIQUES written by MICHEL.. HEMMERLIN and published by . This book was released on 1997 with total page 262 pages. Available in PDF, EPUB and Kindle. Book excerpt: LES SPECTROMETRIES D'EMISSION ATOMIQUE ET DE MASSE ELEMENTAIRE UTILISANT UN PLASMA A COUPLAGE INDUCTIF (ICP-AES ET ICP-MS) SONT DESORMAIS DES TECHNIQUES BIEN ETABLIES POUR L'ANALYSE MULTIELEMENTAIRE DE TRACES DANS DIVERSES MATRICES NATURELLES OU SYNTHETIQUES. GENERALEMENT, L'INTRODUCTION DE L'ECHANTILLON DANS LE PLASMA SE FAIT PAR NEBULISATION PNEUMATIQUE D'UNE SOLUTION ISSUE D'UN TRAITEMENT CHIMIQUE (ATTAQUE) D'UNE MATRICE SOLIDE. CETTE ETAPE DE MISE EN SOLUTION PRESENTE DE NOMBREUSES LIMITATIONS ET EST RENDUE DE PLUS EN PLUS DIFFICILE PAR LA SOLUBILITE RESTREINTE ET LA RESISTANCE CHIMIQUE ELEVEE DE CERTAINS POLYMERES. L'ABLATION LASER, TERME QUI DECRIT LA DESTRUCTION PROGRESSIVE ET SUPERFICIELLE D'UNE CIBLE SOLIDE, EST UNE TECHNIQUE D'INTRODUCTION DE L'ECHANTILLON TRES ATTRACTIVE. OUTRE L'ELIMINATION DE TOUTE PREPARATION CHIMIQUE, ET DONC LE GAIN EN TEMPS D'ANALYSE QU'ELLE OFFRE, CETTE METHODE D'ECHANTILLONNAGE DISPOSE D'UNE RESOLUTION SPATIALE DONNANT ACCES A DES INFORMATIONS NOUVELLES QUANT A LA REPARTITION DES ELEMENTS DANS UNE MATRICE. CEPENDANT, LES PARAMETRES REGISSANT L'INTERACTION LASER-MATIERE SONT ENCORE MAL MAITRISES, ET LES ETUDES CONCERNANT L'ANALYSE DES MATIERES PLASTIQUES PAR ABLATION LASER-PLASMA ICP SONT QUASIMENT INEXISTANTES. L'OBJECTIF DE CE TRAVAIL RESIDE DANS LE DEVELOPPEMENT ET L'EVALUATION ANALYTIQUE DE CE COUPLAGE POUR L'ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DES MATIERES PLASTIQUES. LES PERFORMANCES DE L'ETAPE D'ECHANTILLONNAGE, DONT L'ELEMENT FONDAMENTAL EST LE FAISCEAU LASER ET SES PROPRIETES, ONT ETE ETUDIEES AFIN D'APPROFONDIR NOS CONNAISSANCES DU MECANISME D'INTERACTION LASER-POLYMERE. L'INFLUENCE DE PARAMETRES TELS QUE LA LONGUEUR D'ONDE, L'ENERGIE D'IRRADIATION OU LA FOCALISATION DU FAISCEAU LASER A ETE EVALUEE. LES CONTRIBUTIONS DES EFFETS DE SEUIL D'ABLATION DES POLYMERES ET DES EFFETS D'ECRAN CREES PAR LE MICROPLASMA INDUIT PAR LASER SONT DISCUTEES. L'ETUDE DE L'INFLUENCE DES PROPRIETES DES ECHANTILLONS A REVELE L'IMPORTANCE DE PARAMETRES NOUVEAUX TELS QUE LA STRUCTURE CHIMIQUE DES ADDITIFS DES POLYMERES, OU LES INTERACTIONS ENTRE ADDITIFS ET POLYMERES. L'EVALUATION ANALYTIQUE DU COUPLAGE A MIS EN EXERGUE D'EXCELLENTES PERFORMANCES EN TERMES DE REPRODUCTIBILITE (2-5%), DE LINEARITE DE L'ETALONNAGE, ET DE LIMITES DE DETECTION (INFERIEURES A LA PPB). CES RESULTATS PLACENT CETTE TECHNIQUE A UN RANG DE PERFORMANCE AU MOINS EQUIVALENT A CELUI DE LA FLUORESCENCE X OU DE L'ACTIVATION NEUTRONIQUE POUR L'ANALYSE DES SOLIDES.

Book ETUDE ET CARACTERISATION DU COUPLAGE ABLATION LASER PLASMA H F   I C P

Download or read book ETUDE ET CARACTERISATION DU COUPLAGE ABLATION LASER PLASMA H F I C P written by Frédéric Chartier and published by . This book was released on 1991 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ANALYSE DIRECTE D'ELEMENTS DANS LES SOLIDES, EVITANT LA MISE EN SOLUTION, EST UNE NECESSITE EN SPECTROMETRIE D'EMISSION ATOMIQUE (AES). L'ABLATION LASER PERMET LA PRODUCTION DE PARTICULES QUI PEUVENT ETRE ATOMISEES, EXCITEES ET IONISEES DANS UNE SOURCE SECONDAIRE TELLE QU'UN PLASMA INDUIT PAR HAUTE FREQUENCE (I.C.P.). LE COUPLAGE ABLATION LASER/I.C.P. CONSTITUE LE THEME DE NOTRE ETUDE. L'IMPORTANCE DES CARACTERISTIQUES DU LASER TELLES QUE LE MODE DE FONCTIONNEMENT, LA DUREE DE L'IMPULSION, LA FORME DU FAISCEAU ET LA LONGUEUR D'ONDE EST MISE EN EVIDENCE. LES PERFORMANCES DE L'ENSEMBLE PORTE-EBULLITION/CELLULE D'ABLATION ET LE RENDEMENT DE TRANSPORT SONT EVALUES. LA SELECTION D'UN LASER ADAPTE AUX NECESSITES DE L'ABLATION EST EFFECTUEE PAR L'INTERMEDIAIRE D'UNE ETUDE COMPARATIVE DE DIFFERENTS LASERS ET DE LEURS PARAMETRES (TAUX DE REPETITION, ENERGIE), SUR: L'EFFICACITE D'ABLATION, LA TAILLE ET LA QUANTITE DES AEROSOLS PRODUITS, LES PERFORMANCES ANALYTIQUES EN I.C.P./A.E.S. DIFFERENTES NATURES D'ECHANTILLONS SONT TESTEES: METAUX, VERRES... LES RESULTATS MONTRENT QUE LE LASER A EXCIMERES EST PLUS ADAPTE AU COUPLAGE ABLATION LASER/I.C.P. PAR RAPPORT AU LASER ND:YAG

Book ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D UN SPECTROMETRE D EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D ANALYSE ELEMENTAIRE

Download or read book ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D UN SPECTROMETRE D EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D ANALYSE ELEMENTAIRE written by MARTINE.. CARRE JOUINEAU and published by . This book was released on 1991 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LE PLASMA A COUPLAGE INDUCTIF (ICP) EST UNE SOURCE LARGEMENT UTILISEE EN ANALYSE ELEMENTAIRE PAR SPECTROMETRIE D'EMISSION OPTIQUE. UNE INSTALLATION COMMERCIALE TYPIQUE VA COMPRENDRE: LE PLASMA LUI-MEME, UN GENERATEUR QUI APPORTE L'ENERGIE, UN SYSTEME D'INTRODUCTION D'ECHANTILLON QUI PERMET D'INTRODUIRE LE LIQUIDE DANS LA DECHARGE, UN SYSTEME DE DETECTION OPTIQUE ET UNE CHAINE D'ACQUISITION DU SIGNAL. AFIN D'AMELIORER LE RAPPORT SIGNAL SUR BRUIT DU JY 38 PLUS, COMMERCIALISE PAR JOBIN YVON, NOUS AVONS ETUDIE LES PRINCIPALES CAUSES D'INSTABILITE DUES A CHAQUE PARTIE DE L'APPAREIL. DANS UN PREMIER TEMPS, NOUS AVONS OPTIMISE LES CONDITIONS DE SOURCE POUR OBTENIR LE PLASMA LE PLUS STABLE ET LE PLUS PERFORMANT POSSIBLE. POUR CELA, NOUS AVONS ETUDIE L'INFLUENCE DES DEBITS DE GAZ ET DE LA PUISSANCE DU GENERATEUR SUR LA STABILITE DE L'EMISSION. ENSUITE UNE ETUDE GRANULOMETRIQUE ET VELOCIMETRIQUE DE DIFFERENTS SYSTEMES D'INTRODUCTION D'ECHANTILLON NOUS A PERMIS D'OBSERVER LES MODIFICATIONS DE L'AEROSOL AU COURS DE SON TRANSPORT. POUR COMPLETER NOTRE ETUDE, NOUS AVONS TESTE L'INFLUENCE DE LA RESOLUTION DU MONOCHROMATEUR SUR LE RAPPORT SIGNAL SUR BRUIT. ENFIN, DANS LES CONDITIONS OPTIMALES, NOUS AVONS DETERMINE LES LIMITES DE DETECTION REELLES DE L'APPAREIL, DANS DES SOLUTIONS AQUEUSES ET DANS UNE SOLUTION DE TUNGSTENE A 10 G/L