EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book DIAGNOSTIC DU PLASMA A COUPLAGE INDUCTIF  APPLICATION A L ANALYSE

Download or read book DIAGNOSTIC DU PLASMA A COUPLAGE INDUCTIF APPLICATION A L ANALYSE written by FLORENCE.. SCHAMBEL and published by . This book was released on 1992 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LA SPECTROSCOPIE D'EMISSION ATOMIQUE (AES), ET LA SPECTROMETRIE DE MASSE (MS), ASSOCIEE A UN PLASMA A COUPLAGE INDUCTIF (ICP) RESPECTIVEMENT COMME SOURCE LUMINEUSE ET COMME SOURCE D'ION SONT DES TECHNIQUES D'ANALYSE QUANTITATIVES DES ELEMENTS LES PLUS PERFORMANTES. AU COURS DES DIX DERNIERES ANNEES, LES INSTRUMENTS ICP ONT TROUVE LEUR UTILISATION DANS DES DOMAINES TOUJOURS PLUS NOUVEAUX, OU L'ANALYSE ELEMENTAIRE PAR ICP S'EST IMPOSEE. PARMI LES ANALYSES LES PLUS COURANTES ON PEUT CITER: LES ELEMENTS MAJEURS ET LES ELEMENTS TRACES DANS LES ALLIAGES, LES MINERAIS, LES ROCHES, OU LES SEDIMENTS. LES ELEMENTS CONSIDERES COMME TOXIQUES QUE CE SOIT POUR DES PROBLEMES D'ENVIRONNEMENT OU DANS LE DOMAINE AGROALIMENTAIRE. LA SPECTROSCOPIE D'EMISSION PERMET L'ANALYSE SIMULTANEE DE 70 ELEMENTS NOTAMMENT LES ELEMENTS DIFFICILEMENT EXCITABLES COMME P,S,B OU LES TERRES RARES. ELLE TEND A ETRE REMPLACEE PAR LA SPECTROMETRIE DE MASSE QUI PERMET LA DETERMINATION SIMULTANEE DE 75 ELEMENTS AVEC DE MEILLEURS LIMITES DE DETECTION ET UNE PLUS GRANDE RAPIDITE. LA DIFFERENCE S'EXPRIME SURTOUT QUAND IL S'AGIT SOIT D'ANALYSER DES ELEMENTS TELS QUE U, PT, SE, DONT LES LIMITES DE DETECTION SONT MEDIOCRES EN EMISSION ATOMIQUE; SOIT DE FAIRE DES DOSAGES DANS DES MATRICES TRES RICHES EN RAIES PROVOQUANT DES INTERFERENCES SPECTRALES TELLES U, W, CE, TERRES RARES OU ENCORE DANS LA COMBINAISON DE CES DEUX CAS

Book Etude d un plasma    couplage inductif I C P    27 MHZ  et application    l analyse multi  l  mentaire par spectrom  trie d   mission d un ultra violet d   chantillons g  ologiques

Download or read book Etude d un plasma couplage inductif I C P 27 MHZ et application l analyse multi l mentaire par spectrom trie d mission d un ultra violet d chantillons g ologiques written by G. Labarraque and published by . This book was released on 1984 with total page 194 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Etude d  un plasma    couplage inductif  I  C  P    27 mhz  et application    l  analyse multi  l  mentaire par spectrom  trie d    mission d  ultra violet d    chantillons g  ologiques

Download or read book Etude d un plasma couplage inductif I C P 27 mhz et application l analyse multi l mentaire par spectrom trie d mission d ultra violet d chantillons g ologiques written by and published by . This book was released on 1984 with total page 194 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Etude d un plasma    couplage inductif  I C P    27 MHZ  et application    l analyse multi  l  mentaire par spectom  trie d  mission d ultra violet d   chantillons g  ologiques

Download or read book Etude d un plasma couplage inductif I C P 27 MHZ et application l analyse multi l mentaire par spectom trie d mission d ultra violet d chantillons g ologiques written by Guillaume Labarraque and published by . This book was released on 1984 with total page 218 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book VALIDATION DU COUPLAGE PLASMA  ICP    SPECTROMETRIE DE MASSE POUR L ANALYSE INORGANIQUE  ELEMENTS TRACE  DE MATRICES ALIMENTAIRES D ORIGINE ANIMALE

Download or read book VALIDATION DU COUPLAGE PLASMA ICP SPECTROMETRIE DE MASSE POUR L ANALYSE INORGANIQUE ELEMENTS TRACE DE MATRICES ALIMENTAIRES D ORIGINE ANIMALE written by SYLVIE-ISABELLE.. EXCOFFIER and published by . This book was released on 1997 with total page 290 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'INTERET ACTUELLEMENT PORTE A L'ANALYSE INORGANIQUE DE MATRICES ALIMENTAIRES S'EXPLIQUE PAR LES PROPRIETES NUTRITIONNELLES ET/OU TOXIQUES DES ELEMENTS IMPLIQUES. MAIS LES METHODES D'ANALYSE CONVENTIONNELLES UTILISEES, PRINCIPALEMENT DIFFERENTES TECHNIQUES DE SPECTROMETRIE D'ABSORPTION ATOMIQUE, ONT COMME PRINCIPALE LIMITATION D'ETRE MONO-ELEMENTAIRES. LE COUPLAGE PLASMA - SPECTROMETRIE D'EMISSION ATOMIQUE (ICP-AES) PERMET L'ANALYSE MULTI-ELEMENTAIRE MAIS LES LIMITES DE DETECTION ALORS OBTENUES SONT TROP ELEVEES (DE L'ORDRE DU G/L) POUR CETTE APPLICATION. LE COUPLAGE PLASMA - SPECTROMETRIE DE MASSE, EN ASSOCIANT CAPACITE D'ANALYSE MULTI-ELEMENTAIRE ET FAIBLES LIMITES DE DETECTION (DE L'ORDRE DU NG/L), S'AVERE ETRE UN OUTIL EFFICACE DANS CE CHAMP D'APPLICATIONS SPECIFIQUE. TOUTEFOIS, CET AVANTAGE IMPOSE D'ETABLIR DES COMPROMIS DANS L'OPTIMISATION DE L'ICP-MS AFIN DE PERMETTRE LA DETERMINATION DU PLUS GRAND NOMBRE D'ELEMENTS DANS LES MEILLEURES CONDITIONS. LA PREMIERE ETAPE A ETE DE RECHERCHER SUR DES SOLUTIONS ETALONS UN COMPROMIS ACCEPTABLE POUR L'ENSEMBLE DES ANALYTES (AL, AS, CD, CO, CR, CU, FE, MN, MO, NI, PB, SB, SE, SN ET ZN), DISTRIBUES SUR LA TOTALITE DE LA GAMME DES MASSES (DE 27 A 208 UMA). NOUS AVONS ALORS ETUDIE, POUR DIFFERENTES OPTIMISATIONS, LEURS CARACTERISTIQUES ANALYTIQUES : LINEARITE, SENSIBILITE, REPETABILITE, DERIVE A LONG TERME ET SPECIFICITE DU SIGNAL ASSOCIE. MAIS LES ECHANTILLONS ANALYSES COURAMMENT AU LABORATOIRE DOIVENT SUBIR AU PREALABLE UNE ETAPE NECESSAIRE DE MINERALISATION, ET, A CE NIVEAU DE CONCENTRATION (PPB), LES CONTAMINATIONS SONT FREQUENTES. DANS UNE DEUXIEME ETAPE, NOUS AVONS DONC ETUDIE PAS A PAS LES SOURCES POSSIBLES DE CONTAMINATIONS : QUALITE DES REACTIFS, VAISSELLE UTILISEE... NOUS NOUS SOMMES ENSUITE INTERESSES AUX LIMITES DE DETECTION ET DE QUANTIFICATION (CV = 10%) DE CHAQUE ANALYTE, TANT D'UN POINT DE VUE THEORIQUE QUE PRATIQUE. FINALEMENT, L'ANALYSE D'ECHANTILLONS DE REFERENCE, APRES MINERALISATION PAR VOIE SECHE OU DIGESTION PAR MICRO-ONDES (SYSTEME OUVERT), VALIDE L'ICP-MS COMME METHODE MULTI-ELEMENTAIRE D'ANALYSE INORGANIQUE DE MATRICES ALIMENTAIRES. L'ETAPE DE PREPARATION DE L'ECHANTILLON RESTE NEANMOINS LE MAILLON FAIBLE DE LA CHAINE ANALYTIQUE ET SERAIT A DEVELOPPER DANS LE FUTUR.

Book ETUDE DES PERFORMANCES ANALYTIQUES D UN PLASMA A COUPLAGE INDUCTIF ICP OBSERVE AXIALEMENT EN SPECTROMETRIE D EMISSION

Download or read book ETUDE DES PERFORMANCES ANALYTIQUES D UN PLASMA A COUPLAGE INDUCTIF ICP OBSERVE AXIALEMENT EN SPECTROMETRIE D EMISSION written by CENDRINE.. DUBUISSON and published by . This book was released on 1998 with total page 293 pages. Available in PDF, EPUB and Kindle. Book excerpt: IL EXISTE UN BESOIN CONSTANT D'AMELIORER LES LIMITES DE DETECTION DES METHODES D'ANALYSE ELEMENTAIRE. L'OBSERVATION AXIALE DU PLASMA A ETE PROPOSEE AFIN D'AMELIORER LES LIMITES DE DETECTION DE LA SPECTROMETRIE D'EMISSION ICP, CEPENDANT SON APPORT REEL SUR LES PERFORMANCES ANALYTIQUES DE LA METHODE N'A PAS ENCORE ETE CLAIREMENT ETABLI. NOUS NOUS SOMMES PRINCIPALEMENT INTERESSES AUX LIMITES DE DETECTION ET AUX EFFETS DE MATRICE. L'EVALUATION D'UN NOUVEAU PROTOTYPE A VISEE AXIALE A EGALEMENT ETE REALISEE. NOUS AVONS MONTRE QUE LE FACTEUR D'AMELIORATION MOYEN DES LIMITES DE DETECTION EN VISEE AXIALE EST DE 3 A 4. CE FACTEUR PROVIENT A LA FOIS D'UNE AMELIORATION DU RAPPORT SIGNAL SUR FOND ET DE L'ECART-TYPE RELATIF DU FOND POUR DES CONDITIONS DE MESURE IDENTIQUES. LE PROTOTYPE A VISEE AXIALE QUE NOUS AVONS EVALUE PRESENTE DES LIMITES DE DETECTION PLUS BASSES QUE CELLES DETERMINEES SUR LES SYSTEMES COMMERCIAUX ACTUELS. L'UTILISATION D'UN NEBULISEUR ULTRASONIQUE A PERMIS D'ATTEINDRE DES VALEURS COMPARABLES A CELLES DE L'ICP-MS POUR CERTAINS ELEMENTS. PAR AILLEURS, NOUS AVONS MONTRE QUE LES EFFETS DE MATRICE PEUVENT ETRE MINIMISES EN VISEE AXIALE COMME EN VISEE LATERALE DANS CERTAINES CONDITIONS OPERATOIRES QUI CONDUISENT A UN TRANSFERT D'ENERGIE OPTIMAL ENTRE L'ECHANTILLON ET LE PLASMA. DANS CES CONDITIONS OPERATOIRES APPELEES CONDITIONS ROBUSTES, LA CONTRIBUTION DES PERTURBATIONS LIEES AUX PHENOMENES D'ATOMISATION ET D'EXCITATION DES ELEMENTS EN PRESENCE D'INTERFERENT EST ELIMINEE, L'EFFET RESIDUEL POUVANT ETRE ATTRIBUE A UNE PERTURBATION DU SYSTEME D'INTRODUCTION. IL A ETE MONTRE QUE L'IMPORTANCE DE CES EFFETS VARIE SELON LE NEBULISEUR ET LA CHAMBRE DE NEBULISATION UTILISES. LA CARACTERISATION DES AEROSOLS PRODUITS MONTRE UNE MODIFICATION DES AEROSOLS TERTIAIRES ET/OU PRIMAIRES EN PRESENCE D'INTERFERENT. CES MODIFICATIONS DEPENDENT A LA FOIS DU SYSTEME D'INTRODUCTION ET DES PROPRIETES PHYSIQUES DU LIQUIDE NEBULISE. PAR AILLEURS, NOUS AVONS MIS EN EVIDENCE LE ROLE IMPORTANT DE LA CHAMBRE DE NEBULISATION, DE NOMBREUSES PERTURBATIONS SE PRODUISANT LORS DES PROCESSUS DE FILTRAGE ET DE TRANSPORT DE L'AEROSOL. L'EFFET RESIDUEL OBSERVE EN PRESENCE D'INTERFERENT DANS LES CONDITIONS ROBUSTES A ETE CORRIGE PAR LA METHODE DE L'ETALONNAGE INTERNE. AINSI, L'UTILISATION D'UN SEUL ETALON INTERNE PERMET DE COMPENSER DE FACON EFFICACE UNE DIFFERENCE IMPORTANTE ENTRE LA MATRICE DES ECHANTILLONS ET DES ETALONS POUR TOUTES LES RAIES DANS LES DEUX MODES D'OBSERVATION.

Book Inductively Coupled Plasma Spectrometry and Its Applications

Download or read book Inductively Coupled Plasma Spectrometry and Its Applications written by Steve J. Hill and published by Burns & Oates. This book was released on 1999-01 with total page 370 pages. Available in PDF, EPUB and Kindle. Book excerpt: This volume considers the principles of inductively coupled plasmas, the instrumentation, the methodology and applications within the three principal areas of environmental analysis, earth science and food science. There are two chapters on ICP–MS. No prior knowledge is assumed. To assist the ′hands–on′ user, details of the advantages and disadvantages of the various approaches are included.

Book APPLICATION DE LA SPECTROSCOPIE MOLECULAIRE AU DIAGNOSTIC D UN PLASMA INDUCTIF D ARGON

Download or read book APPLICATION DE LA SPECTROSCOPIE MOLECULAIRE AU DIAGNOSTIC D UN PLASMA INDUCTIF D ARGON written by PAUL-ANDRE.. ABILA and published by . This book was released on 1989 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Liquid Sample Introduction in ICP Spectrometry

Download or read book Liquid Sample Introduction in ICP Spectrometry written by José-Luis Todoli and published by Elsevier. This book was released on 2011-04-18 with total page 301 pages. Available in PDF, EPUB and Kindle. Book excerpt: Inductively coupled plasma atomic or mass spectrometry is one of the most common techniques for elemental analysis. Samples to be analyzed are usually in the form of solutions and need to be introduced into the plasma by means of a sample introduction system, so as to obtain a mist of very fine droplets. Because the sample introduction system can be a limiting factor in the analytical performance, it is crucial to optimize its design and its use. It is the purpose of this book to provide fundamental knowledge along with practical instructions to obtain the best out of the technique. - Fundamental as well as practical character - Troubleshooting section - Flow charts with optimum systems to be used for a given application

Book ETUDE ET CARACTERISATION DU COUPLAGE ABLATION LASER PLASMA H F   I C P

Download or read book ETUDE ET CARACTERISATION DU COUPLAGE ABLATION LASER PLASMA H F I C P written by Frédéric Chartier and published by . This book was released on 1991 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ANALYSE DIRECTE D'ELEMENTS DANS LES SOLIDES, EVITANT LA MISE EN SOLUTION, EST UNE NECESSITE EN SPECTROMETRIE D'EMISSION ATOMIQUE (AES). L'ABLATION LASER PERMET LA PRODUCTION DE PARTICULES QUI PEUVENT ETRE ATOMISEES, EXCITEES ET IONISEES DANS UNE SOURCE SECONDAIRE TELLE QU'UN PLASMA INDUIT PAR HAUTE FREQUENCE (I.C.P.). LE COUPLAGE ABLATION LASER/I.C.P. CONSTITUE LE THEME DE NOTRE ETUDE. L'IMPORTANCE DES CARACTERISTIQUES DU LASER TELLES QUE LE MODE DE FONCTIONNEMENT, LA DUREE DE L'IMPULSION, LA FORME DU FAISCEAU ET LA LONGUEUR D'ONDE EST MISE EN EVIDENCE. LES PERFORMANCES DE L'ENSEMBLE PORTE-EBULLITION/CELLULE D'ABLATION ET LE RENDEMENT DE TRANSPORT SONT EVALUES. LA SELECTION D'UN LASER ADAPTE AUX NECESSITES DE L'ABLATION EST EFFECTUEE PAR L'INTERMEDIAIRE D'UNE ETUDE COMPARATIVE DE DIFFERENTS LASERS ET DE LEURS PARAMETRES (TAUX DE REPETITION, ENERGIE), SUR: L'EFFICACITE D'ABLATION, LA TAILLE ET LA QUANTITE DES AEROSOLS PRODUITS, LES PERFORMANCES ANALYTIQUES EN I.C.P./A.E.S. DIFFERENTES NATURES D'ECHANTILLONS SONT TESTEES: METAUX, VERRES... LES RESULTATS MONTRENT QUE LE LASER A EXCIMERES EST PLUS ADAPTE AU COUPLAGE ABLATION LASER/I.C.P. PAR RAPPORT AU LASER ND:YAG

Book ETUDE ET DEVELOPPEMENT DU COUPLAGE ABLATION LASER   SPECTROMETRIE PLASMA  ICP  POUR L ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DANS LES MATIERES PLASTIQUES

Download or read book ETUDE ET DEVELOPPEMENT DU COUPLAGE ABLATION LASER SPECTROMETRIE PLASMA ICP POUR L ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DANS LES MATIERES PLASTIQUES written by MICHEL.. HEMMERLIN and published by . This book was released on 1997 with total page 262 pages. Available in PDF, EPUB and Kindle. Book excerpt: LES SPECTROMETRIES D'EMISSION ATOMIQUE ET DE MASSE ELEMENTAIRE UTILISANT UN PLASMA A COUPLAGE INDUCTIF (ICP-AES ET ICP-MS) SONT DESORMAIS DES TECHNIQUES BIEN ETABLIES POUR L'ANALYSE MULTIELEMENTAIRE DE TRACES DANS DIVERSES MATRICES NATURELLES OU SYNTHETIQUES. GENERALEMENT, L'INTRODUCTION DE L'ECHANTILLON DANS LE PLASMA SE FAIT PAR NEBULISATION PNEUMATIQUE D'UNE SOLUTION ISSUE D'UN TRAITEMENT CHIMIQUE (ATTAQUE) D'UNE MATRICE SOLIDE. CETTE ETAPE DE MISE EN SOLUTION PRESENTE DE NOMBREUSES LIMITATIONS ET EST RENDUE DE PLUS EN PLUS DIFFICILE PAR LA SOLUBILITE RESTREINTE ET LA RESISTANCE CHIMIQUE ELEVEE DE CERTAINS POLYMERES. L'ABLATION LASER, TERME QUI DECRIT LA DESTRUCTION PROGRESSIVE ET SUPERFICIELLE D'UNE CIBLE SOLIDE, EST UNE TECHNIQUE D'INTRODUCTION DE L'ECHANTILLON TRES ATTRACTIVE. OUTRE L'ELIMINATION DE TOUTE PREPARATION CHIMIQUE, ET DONC LE GAIN EN TEMPS D'ANALYSE QU'ELLE OFFRE, CETTE METHODE D'ECHANTILLONNAGE DISPOSE D'UNE RESOLUTION SPATIALE DONNANT ACCES A DES INFORMATIONS NOUVELLES QUANT A LA REPARTITION DES ELEMENTS DANS UNE MATRICE. CEPENDANT, LES PARAMETRES REGISSANT L'INTERACTION LASER-MATIERE SONT ENCORE MAL MAITRISES, ET LES ETUDES CONCERNANT L'ANALYSE DES MATIERES PLASTIQUES PAR ABLATION LASER-PLASMA ICP SONT QUASIMENT INEXISTANTES. L'OBJECTIF DE CE TRAVAIL RESIDE DANS LE DEVELOPPEMENT ET L'EVALUATION ANALYTIQUE DE CE COUPLAGE POUR L'ANALYSE ELEMENTAIRE IN SITU DES ADDITIFS DES MATIERES PLASTIQUES. LES PERFORMANCES DE L'ETAPE D'ECHANTILLONNAGE, DONT L'ELEMENT FONDAMENTAL EST LE FAISCEAU LASER ET SES PROPRIETES, ONT ETE ETUDIEES AFIN D'APPROFONDIR NOS CONNAISSANCES DU MECANISME D'INTERACTION LASER-POLYMERE. L'INFLUENCE DE PARAMETRES TELS QUE LA LONGUEUR D'ONDE, L'ENERGIE D'IRRADIATION OU LA FOCALISATION DU FAISCEAU LASER A ETE EVALUEE. LES CONTRIBUTIONS DES EFFETS DE SEUIL D'ABLATION DES POLYMERES ET DES EFFETS D'ECRAN CREES PAR LE MICROPLASMA INDUIT PAR LASER SONT DISCUTEES. L'ETUDE DE L'INFLUENCE DES PROPRIETES DES ECHANTILLONS A REVELE L'IMPORTANCE DE PARAMETRES NOUVEAUX TELS QUE LA STRUCTURE CHIMIQUE DES ADDITIFS DES POLYMERES, OU LES INTERACTIONS ENTRE ADDITIFS ET POLYMERES. L'EVALUATION ANALYTIQUE DU COUPLAGE A MIS EN EXERGUE D'EXCELLENTES PERFORMANCES EN TERMES DE REPRODUCTIBILITE (2-5%), DE LINEARITE DE L'ETALONNAGE, ET DE LIMITES DE DETECTION (INFERIEURES A LA PPB). CES RESULTATS PLACENT CETTE TECHNIQUE A UN RANG DE PERFORMANCE AU MOINS EQUIVALENT A CELUI DE LA FLUORESCENCE X OU DE L'ACTIVATION NEUTRONIQUE POUR L'ANALYSE DES SOLIDES.

Book ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D UN SPECTROMETRE D EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D ANALYSE ELEMENTAIRE

Download or read book ETUDE ET AMELIORATION DU RAPPORT SIGNAL SUR BRUIT D UN SPECTROMETRE D EMISSION ATOMIQUE A SOURCE PLASMA INDUIT PAR HAUTE FREQUENCE A DES FINS D ANALYSE ELEMENTAIRE written by MARTINE.. CARRE JOUINEAU and published by . This book was released on 1991 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: LE PLASMA A COUPLAGE INDUCTIF (ICP) EST UNE SOURCE LARGEMENT UTILISEE EN ANALYSE ELEMENTAIRE PAR SPECTROMETRIE D'EMISSION OPTIQUE. UNE INSTALLATION COMMERCIALE TYPIQUE VA COMPRENDRE: LE PLASMA LUI-MEME, UN GENERATEUR QUI APPORTE L'ENERGIE, UN SYSTEME D'INTRODUCTION D'ECHANTILLON QUI PERMET D'INTRODUIRE LE LIQUIDE DANS LA DECHARGE, UN SYSTEME DE DETECTION OPTIQUE ET UNE CHAINE D'ACQUISITION DU SIGNAL. AFIN D'AMELIORER LE RAPPORT SIGNAL SUR BRUIT DU JY 38 PLUS, COMMERCIALISE PAR JOBIN YVON, NOUS AVONS ETUDIE LES PRINCIPALES CAUSES D'INSTABILITE DUES A CHAQUE PARTIE DE L'APPAREIL. DANS UN PREMIER TEMPS, NOUS AVONS OPTIMISE LES CONDITIONS DE SOURCE POUR OBTENIR LE PLASMA LE PLUS STABLE ET LE PLUS PERFORMANT POSSIBLE. POUR CELA, NOUS AVONS ETUDIE L'INFLUENCE DES DEBITS DE GAZ ET DE LA PUISSANCE DU GENERATEUR SUR LA STABILITE DE L'EMISSION. ENSUITE UNE ETUDE GRANULOMETRIQUE ET VELOCIMETRIQUE DE DIFFERENTS SYSTEMES D'INTRODUCTION D'ECHANTILLON NOUS A PERMIS D'OBSERVER LES MODIFICATIONS DE L'AEROSOL AU COURS DE SON TRANSPORT. POUR COMPLETER NOTRE ETUDE, NOUS AVONS TESTE L'INFLUENCE DE LA RESOLUTION DU MONOCHROMATEUR SUR LE RAPPORT SIGNAL SUR BRUIT. ENFIN, DANS LES CONDITIONS OPTIMALES, NOUS AVONS DETERMINE LES LIMITES DE DETECTION REELLES DE L'APPAREIL, DANS DES SOLUTIONS AQUEUSES ET DANS UNE SOLUTION DE TUNGSTENE A 10 G/L

Book Proceedings of the Ocean Drilling Program

Download or read book Proceedings of the Ocean Drilling Program written by Ocean Drilling Program and published by . This book was released on 1991 with total page 800 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Analytical Method Development and Validation

Download or read book Analytical Method Development and Validation written by Michael E. Swartz and published by CRC Press. This book was released on 2018-10-03 with total page 95 pages. Available in PDF, EPUB and Kindle. Book excerpt: Describes analytical methods development, optimization and validation, and provides examples of successful methods development and validation in high-performance liquid chromatography (HPLC) areas. The text presents an overview of Food and Drug Administration (FDA)/International Conference on Harmonization (ICH) regulatory guidelines, compliance with validation requirements for regulatory agencies, and methods validation criteria stipulated by the US Pharmacopia, FDA and ICH.

Book Isotopic Analysis

    Book Details:
  • Author : Frank Vanhaecke
  • Publisher : John Wiley & Sons
  • Release : 2012-04-24
  • ISBN : 3527650504
  • Pages : 565 pages

Download or read book Isotopic Analysis written by Frank Vanhaecke and published by John Wiley & Sons. This book was released on 2012-04-24 with total page 565 pages. Available in PDF, EPUB and Kindle. Book excerpt: Edited by two very well-known and respected scientists in the field, this excellent practical guide is the first to cover the fundamentals and a wide range of applications, as well as showing readers how to efficiently use this increasingly important technique. From the contents: * The Isotopic Composition of the Elements * Single-Collector ICP-MS * Multi-Collector ICP-MS * Advances in Laser Ablation - Multi-Collector ICP-MS * Correction for Instrumental Mass Discrimination in Isotope Ratio Determination with Multi-Collector ICP-MS * Reference Materials in Isotopic Analysis * Quality Control in Isotope Ratio Applications * Determination of Trace Elements and Elemental Species Using Isotope Dilution ICP-MS * Geochronological Dating * Application of Multi-Collector ICP-MS to Isotopic Analysis in Cosmochemistry * Establishing the Basis for Using Stable Isotope Ratios of Metals as Paleoredox Proxies * Isotopes as Tracers of Elements Across the Geosphere-Biosphere Interface * Archaeometric Applications * Forensics Applications * Nuclear Applications * The Use of Stable Isotope Techniques for Studying Mineral and Trace Element Metabolism in Humans * Isotopic Analysis via Multi-Collector ICP-MS in Elemental Speciation A must-have for newcomers as well as established scientists seeking an overview of isotopic analysis via ICP-MS.

Book Sample Introduction Systems in ICPMS and ICPOES

Download or read book Sample Introduction Systems in ICPMS and ICPOES written by Diane Beauchemin and published by Newnes. This book was released on 2020-03-15 with total page 588 pages. Available in PDF, EPUB and Kindle. Book excerpt: Sample Introduction Systems in ICPMS and ICPOES provides an in-depth analysis of sample introduction strategies, including flow injection analysis and less common techniques, such as arc/spark ablation and direct sample insertion. The book critically evaluates what has been accomplished so far, along with what can be done to extend the capabilities of the technique for analyses of any type of sample, such as aqueous, gaseous or solid. The latest progress made in fields, such as FIA, ETV, LC-ICP-MS and CE-ICP-MS is included and critically discussed. The book addresses problems related to the optimization of the system, peak dispersion and calibration and automatization. - Provides contributions from recognized experts that give credibility to each chapter as a reference source - Presents a single source, providing the big picture for ICPMS and ICPOES - Covers theory, methods, selected applications and discrete sampling techniques - Includes access to core data for practical work, comparison of results and decision-making

Book Mass Spectrometry Handbook

Download or read book Mass Spectrometry Handbook written by Mike S. Lee and published by John Wiley & Sons. This book was released on 2012-04-16 with total page 1362 pages. Available in PDF, EPUB and Kindle. Book excerpt: Due to its enormous sensitivity and ease of use, mass spectrometry has grown into the analytical tool of choice in most industries and areas of research. This unique reference provides an extensive library of methods used in mass spectrometry, covering applications of mass spectrometry in fields as diverse as drug discovery, environmental science, forensic science, clinical analysis, polymers, oil composition, doping, cellular research, semiconductor, ceramics, metals and alloys, and homeland security. The book provides the reader with a protocol for the technique described (including sampling methods) and explains why to use a particular method and not others. Essential for MS specialists working in industrial, environmental, and clinical fields.