Download or read book TRAITEMENT DES LUXATIONS CONGENITALES HAUTES DE HANCHE CHEZ L ADULTE PAR PROTHESE TOTALE SUR MESURE RECENTREE written by JEAN-YVES.. SIMONET and published by . This book was released on 1993 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book La proth se totale dans le traitement de la luxation cong nitale de hanche haute inv t r e chez l adulte written by Alain Govin and published by . This book was released on 1979 with total page 150 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book CONCEPTION ACTUELLE DU TRAITEMENT DES LUXATIONS CONGENITALES DE HANCHE CHEZ L ADULTE PAR L ARTHROPLASTIE TOTALE RECENTREE written by SLAWOMIR.. PROCYK and published by . This book was released on 1990 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book PLACE DE L ARTHROPLASTIE TOTALE RECENTREE DANS LE TRAITEMENT CHIRURGICAL DE LA LUXATION CONGENITALE DE LA HANCHE VIEILLIE DE L ADULTE written by JEAN-LOUIS.. BOISARD and published by . This book was released on 1983 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book DISCUSSION DES INDICATIONS DE L ARTHROPLASTIE TOTALE DE HANCHE PAR PROTHESE DANS LES LUXATIONS CONGENITALES HAUTES INVETEREES CHEZ L ADULTE written by Christophe Denis and published by . This book was released on 1988 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book La Proth se totale dans les s quelles majeures de luxations cong nitales de hanche written by Marc Lombard (médecin.) and published by . This book was released on 1977 with total page 162 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book Traitement des luxations cong nitales inv t r es de hanche l ge adulte par arthroplastie totale written by Denis Huten and published by . This book was released on 1978 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book LES PROTHESES TOTALES DE HANCHE DANS LES LUXATIONS CONGENITALES DE HANCHE DE L ADULTE written by MARIANNE.. METIVIER and published by . This book was released on 1986 with total page 132 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book Traitement de la luxation cong nitale de la hanche chez l enfant g et chez l adulte written by Léon Grandgerard and published by . This book was released on 1909 with total page 148 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book La Proth se totale dans les s quelles de luxations cong nitales de la hanche written by Christian Nourissat and published by . This book was released on 1973* with total page 150 pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book L Arthroplastie totale de la hanche dans les luxations cong nitales de la hanche chez l adulte written by Jean-François Lozé (médecin.) and published by . This book was released on 1977 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:
Download or read book Proth se totale de la hanche sur mesure written by Ibrahim Ghaddar and published by . This book was released on 1990 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Seize patients porteurs de dix neuf prothèses totales de hanche sur mesure ont été revus. Il s'agit de patients traités dans le service du Pr. P. GRAMMONT à Dijon et dans le service du Pr. J.-L. LERAT à Dijon. L'indication a été portée sept fois pour une dysplasie sévère ou une luxation congénitale de hanche, et douze fois pour une coxarthrose. L'implant fémoral sur mesure est fabriqué en trois étapes : réalisation de coupes radiotomodensitométriques sur les quinze premiers centimètres de l'extrémité proximale du fémur selon un protocole mis au point avec les radiologues du C.H.U. de Dijon (Pr. D. BINNERT, Dr. J.-F. COUAILLIER). A partir de ces coupes, un moule de la morphologie du canal médullaire proximal du fémur est réalisé après digitalisation des coupes (M. PEGUET) et modélisation de la forme selon la méthode des splines paramétrés (P. CINQUIN). Conception d'une tigé fémorale en fonction de la forme du moule médullaire, en prenant compte de nos choix biomécaniques pour la répartition du transfert des charges entrela prothèse et l'os et les conditions d'emboîtement. Cette modélisation est réalisée sur ordinateur grâce à un logiciel mis au point à Dijon par B. CHALMONT. Fabrication de la tige sur machine à commande numérique selon les côtes précédemment choisies. Sur le plan clinique : chez trois patients, la congruence de la tige et du fémur n'a pas été suffisante poru obtenir une stabilité primaire. Chez les treize autres patients, les conditions d'implantation ont permis un appui complet immédiatement après l'intervention : il n'a pas été noté de douleur, tout au plus une gêne lors de la marche jusque vers le troisième mois post-opératoire. Cette gêne a toujous disparu après le sixième mois. Sur le plan radiologique : avec un recul de trois ans et demi maximum, nous n'avons pas observé de modification significative de la trame osseuse, en particulier au niveau sous trochantérien, sous le Merckel ni en bout de tige. Un recul plus important sera nécessaire pour valider l'intérêt de nos choix mécaniques sur le comportement de l'os et des implants.