EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book LIMB Demonstration Project Extension

Download or read book LIMB Demonstration Project Extension written by and published by . This book was released on 1990 with total page 22 pages. Available in PDF, EPUB and Kindle. Book excerpt: The DOE LIMB Demonstration Project Extension is a continuation of the EPA Limestone Injection Multistage Burner (LIMB) Demonstration. EPA ultimately expects to show that LIMB is a low cost control technology capable of producing moderate SO(subscript x) and NO(subscript x) control (50--60 percent) with applicability for retrofit to the major portion of the existing coal-fired boiler population. The current EPA Wall-Fired LIMB Demonstration is a four-year project that includes design and installation of a LIMB system at the 105-MW Unit 4 boiler at Ohio Edison's Edgewater Station in Lorain, Ohio. LIMB Extension testing continued during the quarter with lignosulfonated hydrated lime, pulverized limestone, and hydrated dolomitic lime while firing 1.8% and 3% sulfur coals. Sulfur dioxide removal efficiencies were equivalent to the results found during EPA, base LIMB testing. Sulfur dioxide removal efficiencies were lower than expected while testing with pulverized limestone without humidification. A slight increase in sulfur capture was noted while injecting pulverized limestone at the 187' elevation and with the humidifier outlet temperature at 145°F.

Book LIMB Demonstration Project Extension

Download or read book LIMB Demonstration Project Extension written by and published by . This book was released on 1988 with total page 24 pages. Available in PDF, EPUB and Kindle. Book excerpt: The basic goal of the Limestone Injection Multistage Burner (LIMB) demonstration is to extend LIMB technology development to a full-scale application on a representative wall-fired utility boiler. The successful retrofit of LIMB to an existing boiler is expected to demonstrate that (a) reductions of 50 percent or greater in SO(subscript x) and NO(subscript x) emissions can be achieved at a fraction of the cost of add-on FGD systems, (b) boiler reliability, operability, and steam production can be maintained at levels existing prior to LIMB retrofit, and (c) technical difficulties attributable to LIMB operation, such as additional slagging and fouling, changes in ash disposal requirements, and an increased particulate load, can be resolved in a cost-effective manner. The primary fuel to be used will be an Ohio bituminous coal having a nominal sulfur content of 3 percent or greater.

Book LIMB Demonstration Project Extension and Coolside Demonstration   Final Report

Download or read book LIMB Demonstration Project Extension and Coolside Demonstration Final Report written by and published by . This book was released on 1992 with total page 294 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report presents results from the limestone Injection Multistage Burner (LIMB) Demonstration Project Extension. LIMB is a furnace sorbent injection technology designed for the reduction of sulfur dioxide (SO2) and nitrogen oxides (NO3 emissions from coal-fired utility boilers. The testing was conducted on the 105 Mwe, coal-fired, Unit 4 boiler at Ohio Edisons̀ Edgewater Station in Lorain, Ohio. In addition to the LIMB Extension activities, the overall project included demonstration of the Coolside process for S02 removal for which a separate report has been issued. The primary purpose of the DOE LIMB Extension testing, was to demonstrate the generic applicability of LIMB technology. The program sought to characterize the S02 emissions that result when various calcium-based sorbents are injected into the furnace, while burning coals having sulfur content ranging from 1.6 to 3.8 weight percent. The four sorbents used included calcitic limestone, dolomitic hydrated lime, calcitic hydrated lime, and calcitic hydrated lime with a small amount of added calcium lignosulfonate. The results include those obtained for the various coal/sorbent combinations and the effects of the LIMB process on boiler and plant operations.

Book LIMB Demonstration Project Extension and Coolside Demonstration

Download or read book LIMB Demonstration Project Extension and Coolside Demonstration written by and published by . This book was released on 1992 with total page 294 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report presents results from the limestone Injection Multistage Burner (LIMB) Demonstration Project Extension. LIMB is a furnace sorbent injection technology designed for the reduction of sulfur dioxide (SO[sub 2]) and nitrogen oxides (NO[sub x]) emissions from coal-fired utility boilers. The testing was conducted on the 105 Mwe, coal-fired, Unit 4 boiler at Ohio Edison's Edgewater Station in Lorain, Ohio. In addition to the LIMB Extension activities, the overall project included demonstration of the Coolside process for S0[sub 2] removal for which a separate report has been issued. The primary purpose of the DOE LIMB Extension testing, was to demonstrate the generic applicability of LIMB technology. The program sought to characterize the S0[sub 2] emissions that result when various calcium-based sorbents are injected into the furnace, while burning coals having sulfur content ranging from 1.6 to 3.8 weight percent. The four sorbents used included calcitic limestone, dolomitic hydrated lime, calcitic hydrated lime, and calcitic hydrated lime with a small amount of added calcium lignosulfonate. The results include those obtained for the various coal/sorbent combinations and the effects of the LIMB process on boiler and plant operations.

Book LIMB Demonstration Project Extension  Quarterly Report No  5  May  June and July 1988

Download or read book LIMB Demonstration Project Extension Quarterly Report No 5 May June and July 1988 written by and published by . This book was released on 1988 with total page 25 pages. Available in PDF, EPUB and Kindle. Book excerpt: The basic goal of the Limestone Injection Multistage Burner (LIMB) demonstration is to extend LIMB technology development to a full-scale application on a representative wall-fired utility boiler. The successful retrofit of LIMB to an existing boiler is expected to demonstrate that (a) reductions of 50 percent or greater in SO and NO emissions can be achieved at a fraction of the cost of add-on FGD systems, (b) boiler reliability, operability, and steam production can be maintained at levels existing prior to LIMB retrofit, and (c) technical difficulties attributable to LIMB operation, such as additional slagging and fouling, changes in ash disposal requirements, and an increased particulate load, can be resolved in a cost-effective manner. The primary fuel to be used will be an Ohio bituminous coal having a nominal sulfur content of 3 percent or greater.

Book LIMB Demonstration Project Extension  Quarterly Report No  18  August  October 1991

Download or read book LIMB Demonstration Project Extension Quarterly Report No 18 August October 1991 written by and published by . This book was released on 1991 with total page 17 pages. Available in PDF, EPUB and Kindle. Book excerpt: The main objectives of this project are: (1) To demonstrate the general applicability of Limestone Injection Multistage Burner (LIMB) technology by testing 3 coals and 4 sorbents (total of 12 coal/sorbent combinations) at the Ohio Edison Edgewater Plant. (2) To demonstrate that Coolside is a viable technology for improving precipitator performance and reducing sulfur dioxide emissions while acceptance operability is maintained. During the past quarter, activities for phase I, design and permitting, and phase II, construction, shakedown and start-up were completed for phase III, operation, data collection, reporting and disposition, activities continued with consol completing the revisions to the Coolside Topical report, the completion of LIMB Extension testing, and the start of demobilization and restoration.

Book LIMB Demonstration Project Extension  Quarterly Report No  8  February  March  and April  1989

Download or read book LIMB Demonstration Project Extension Quarterly Report No 8 February March and April 1989 written by and published by . This book was released on 1989 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt: The basic goal of the Limestone Injection Multistage Burner (LIMB) demonstration is to extend LIMB technology development to a full- scale application on a representative wall-fired utility boiler. The successful retrofit of LIMB to an existing boiler is expected to demonstrate that (a) reductions of 50 percent or greater in SO(subscript x) and NO(subscript x) emissions can be achieved at a fraction of the cost of add-on FGD systems, (b) boiler reliability, operability, and steam production can be maintained at levels existing prior to LIMB retrofit, and (c) technical difficulties attributable to LIMB operation, such as additional slagging and fouling, changes in ash disposal requirements, and an increased particulate load, can be resolved in a cost-effective manner. The primary fuel to be used will be an Ohio bituminous coal having a nominal sulfur content of 3 percent or greater.

Book LIMB Demonstration Project Extension  Quarterly Report No  6  August  October  1988

Download or read book LIMB Demonstration Project Extension Quarterly Report No 6 August October 1988 written by and published by . This book was released on 1988 with total page 21 pages. Available in PDF, EPUB and Kindle. Book excerpt: The basic goal of the Limestone Injection Multistage Burner (LIMB) demonstration is to extend LIMB technology development to a full- scale application on a representative wall-fired utility boiler. The successful retrofit of LIMB to an existing boiler is expected to demonstrate that (a) reductions of 50 percent or greater in SO(subscript x) and NO(subscript x) emissions can be achieved at a fraction of the cost of add-on FGD systems, (b) boiler reliability, operability, and steam production can be maintained at levels existing prior to LIMB retrofit, and (c) technical difficulties attributable to LIMB operation, such as additional slagging and fouling, changes in ash disposal requirements, and an increased particulate load, can be resolved in a cost-effective manner. The primary fuel to be used will be an Ohio bituminous coal having a nominal sulfur content of 3 percent or greater.

Book LIMB Demonstration Project Extension  Quarterly Report No  10  August  September  and October  1989

Download or read book LIMB Demonstration Project Extension Quarterly Report No 10 August September and October 1989 written by and published by . This book was released on 1989 with total page 22 pages. Available in PDF, EPUB and Kindle. Book excerpt: The basic goal of the Limestone Injection Mitigation Burner (LIMB) demonstration is to extend LIMB technology development to a full- scale application on a representative wall-fired utility boiler. The successful retrofit of LIMB to an existing boiler is expected to demonstrate that (a) reductions of 50 percent or greater in SO(subscript x) and NO(subscript x) emissions can be achieved at a fraction of the cost of add-on FGD systems, (b) boiler reliability, operability, and steam production can be maintained at levels existing prior to LIMB retrofit, and (c) technical difficulties attributable to LIMB operation, such as additional slagging and fouling, changes in ash disposal requirements, and an increased particulate load, can be resolved in a cost-effective manner. The primary fuel to be used will be an Ohio bituminous coal having a nominal sulfur content of 3 percent or greater.

Book LIMB Demonstration Project Extension  Quarterly Report No  3  November  December 1987  January 1988

Download or read book LIMB Demonstration Project Extension Quarterly Report No 3 November December 1987 January 1988 written by and published by . This book was released on 1988 with total page 24 pages. Available in PDF, EPUB and Kindle. Book excerpt: The basic goal of the Limestone Injection Multistage Burner (LIMB) demonstration is to extend LIMB technology development to a full-scale application on a representative wall-fired utility boiler. The successful retrofit of LIMB to an existing boiler is expected to demonstrate that (a) reductions of 50 percent or greater in SO(subscript x) and NO(subscript x) emissions can be achieved at a fraction of the cost of add-on FGD systems, (b) boiler reliability, operability, and steam production can be maintained at levels existing prior to LIMB retrofit, and (c) technical difficulties attributable to LIMB operation, such as additional slagging and fouling, changes in ash disposal requirements, and an increased particulate load, can be resolved in a cost-effective manner. The primary fuel to be used will be an Ohio bituminous coal having a nominal sulfur content of 3 percent or greater.

Book LIMB Demonstration Project Extension  Quarterly Report No  7  November and December  1988  and January  1989

Download or read book LIMB Demonstration Project Extension Quarterly Report No 7 November and December 1988 and January 1989 written by and published by . This book was released on 1989 with total page 22 pages. Available in PDF, EPUB and Kindle. Book excerpt: The basic goal of the Limestone Injection Multistage Burner (LIMB) demonstration is to extend LIMB technology development to a full- scale application on a representative wall-fired utility boiler. The successful retrofit of LIMB to an existing boiler is expected to demonstrate that (a) reductions of 50 percent or greater in SO(subscript x) and NO(subscript x) emissions can be achieved at a fraction of the cost of add-on FGD systems, (b) boiler reliability, operability, and steam production can be maintained at levels existing prior to LIMB retrofit, and (c) technical difficulties attributable to LIMB operation, such as additional slagging and fouling, changes in ash disposal requirements, and an increased particulate load, can be resolved in a cost-effective manner. The primary fuel to be used will be an Ohio bituminous coal having a nominal sulfur content of 3 percent or greater.

Book LIMB Demonstration Project Extension and Coolside Demonstration

Download or read book LIMB Demonstration Project Extension and Coolside Demonstration written by and published by . This book was released on 2000 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The goal of the US Department of Energy (DOE) Clean Coal Technology (CCT) program is to furnish the energy marketplace with a number of advanced, more efficient, and environmentally responsible coal utilization technologies through demonstration projects. These projects seek to establish the commercial feasibility of the most promising advanced coal technologies that have already reached the proof-of-concept stage. This document serves as a DOE post-project assessment of the CCT Round 1 project ''LIMB Demonstration Project Extension and Coolside Demonstration'', described in a report to Congress (Babcock and Wilcox 1987), a paper by DePero et al. (1992), and in a report by Goots et al. (1992). The original limestone injection multistage burner (LIMB) demonstration work was conducted by Babcock and Wilcox Company (B and W) beginning in 1984, under the sponsorship of the US Environmental Protection Agency (EPA) and the State of Ohio Coal Development Office (OCDO). In 1987, B and W and the Ohio Edison Company agreed to extend the full-scale demonstration of LIMB technology under the sponsorship of DOE through its CCT Program, and with support from OCDO and Consolidation Coal Company, now known as CONSOL. In a separate effort, CONSOL had been developing another flue gas desulfurization (FGD) technology known as the Coolside process. Both LIMB and Coolside use sorbent injection to remove SO2. The LIMB process injects the sorbent into the furnace and the Coolside injects the sorbent into the flue gas duct. In addition, LIMB uses low-NO(subscript x) burners to reduce NO(subscript x) emissions; hence it is categorized as a combination SO2/NO(subscript x) control technology. To take advantage of synergism between the two processes, the CCT project was structured to incorporate demonstration of both the LIMB and Coolside processes. Coolside testing was accomplished between July 1989 and February 1990, and the LIMB Extension test program was conducted between April 1990 and August 1991. The host site for both tests was the 105 MWe coal-fired Unit 4 at Ohio Edison's Edgewater Station in Lorain, Ohio. The major performance objectives of this project were successfully achieved, with SO2 emissions reductions of up to 70% demonstrated in both processes.

Book Coolside and LIMB

Download or read book Coolside and LIMB written by and published by DIANE Publishing. This book was released on 1990 with total page 32 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Flue Gas Desulfurization and Industrial Minerals

Download or read book Flue Gas Desulfurization and Industrial Minerals written by M. Michael Miller and published by . This book was released on 1993 with total page 720 pages. Available in PDF, EPUB and Kindle. Book excerpt: Contains 4,101 references on FGD [Flue Gas Desulfurization] ... primarily from 1982 through June 1993. Complements the "Flue Gas Desulfurization and Denitrification" bibliography published by the U.S. Dept. of Energy in Jan. 1985. References were located on the Energy, Science and Technology, Pollution Abstracts, and Environmental Bibliography databases. Primarily covers FGD and the use of industrial minerals in the desulfurization process or in by-product utilization and disposal. Emphasizes post-combustion removal of sulfur dioxide through processes such as in-duct injection and wet and dry scrubbing.

Book Clean Coal Technology Demonstration Program

Download or read book Clean Coal Technology Demonstration Program written by Gene H. Knight and published by DIANE Publishing. This book was released on 2001-08 with total page 315 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Clean Coal Technology Demonstration (CCT Program), a model of government & industry cooperation, advances the Dept. of Energy's (DoE) mission to foster a secure & reliable energy system that is environmentally & economically sustainable. This report discusses the Fiscal Year 2000 CCT Program. Sections include: role of the CCT Program; program implementation; funding & costs; CCT Program accomplishments; CCT projects; historical perspective & legislative history; program history; environmental aspects; CCT project contacts; acronyms, abbreviations & symbols; & index of CCT projects & participants.

Book Energy Research Abstracts

Download or read book Energy Research Abstracts written by and published by . This book was released on 1993 with total page 754 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Department of the Interior and Related Agencies Appropriations for 1990  Economic Regulatory Administration

Download or read book Department of the Interior and Related Agencies Appropriations for 1990 Economic Regulatory Administration written by United States. Congress. House. Committee on Appropriations. Subcommittee on Department of the Interior and Related Agencies and published by . This book was released on 1989 with total page 814 pages. Available in PDF, EPUB and Kindle. Book excerpt: