EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Energy Penalty Analysis of Possible Cooling Water Intake Structurerequirements on Existing Coal fired Power Plants

Download or read book Energy Penalty Analysis of Possible Cooling Water Intake Structurerequirements on Existing Coal fired Power Plants written by D. N. Smith and published by . This book was released on 2006 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Section 316(b) of the Clean Water Act requires that cooling water intake structures must reflect the best technology available for minimizing adverse environmental impact. Many existing power plants in the United States utilize once-through cooling systems to condense steam. Once-through systems withdraw large volumes (often hundreds of millions of gallons per day) of water from surface water bodies. As the water is withdrawn, fish and other aquatic organisms can be trapped against the screens or other parts of the intake structure (impingement) or if small enough, can pass through the intake structure and be transported through the cooling system to the condenser (entrainment). Both of these processes can injure or kill the organisms. EPA adopted 316(b) regulations for new facilities (Phase I) on December 18, 2001. Under the final rule, most new facilities could be expected to install recirculating cooling systems, primarily wet cooling towers. The EPA Administrator signed proposed 316(b) regulations for existing facilities (Phase II) on February 28, 2002. The lead option in this proposal would allow most existing facilities to achieve compliance without requiring them to convert once-through cooling systems to recirculating systems. However, one of the alternate options being proposed would require recirculating cooling in selected plants. EPA is considering various options to determine best technology available. Among the options under consideration are wet-cooling towers and dry-cooling towers. Both types of towers are considered to be part of recirculating cooling systems, in which the cooling water is continuously recycled from the condenser, where it absorbs heat by cooling and condensing steam, to the tower, where it rejects heat to the atmosphere before returning to the condenser. Some water is lost to evaporation (wet tower only) and other water is removed from the recirculating system as a blow down stream to control the building up of suspended and dissolved solids. Makeup water is withdrawn, usually from surface water bodies, to replace the lost water. The volume of makeup water is many times smaller than the volume needed to operate a once-through system. Although neither the final new facility rule nor the proposed existing facility rule require dry cooling towers as the national best technology available, the environmental community and several States have supported the use of dry-cooling technology as the appropriate technology for addressing adverse environmental impacts. It is possible that the requirements included in the new facility rule and the ongoing push for dry cooling systems by some stakeholders may have a role in shaping the rule for existing facilities. The temperature of the cooling water entering the condenser affects the performance of the turbine--the cooler the temperature, the better the performance. This is because the cooling water temperature affects the level of vacuum at the discharge of the steam turbine. As cooling water temperatures decrease, a higher vacuum can be produced and additional energy can be extracted. On an annual average, once-through cooling water has a lower temperature than recirculated water from a cooling tower. By switching a once-through cooling system to a cooling tower, less energy can be generated by the power plant from the same amount of fuel. This reduction in energy output is known as the energy penalty. If a switch away from once-through cooling is broadly implemented through a final 316(b) rule or other regulatory initiatives, the energy penalty could result in adverse effects on energy supplies. Therefore, in accordance with the recommendations of the Report of the National Energy Policy Development Group (better known as the May 2001 National Energy Policy), the U.S. Department of Energy (DOE), through its Office of Fossil Energy, National Energy Technology Laboratory (NETL), and Argonne National Laboratory (ANL), has studied the energy penalty resulting from converting plants with once-through cooling to wet towers or indirect-dry towers. Five locations--Delaware River Basin (Philadelphia), Michigan/Great Lakes (Detroit), Ohio River Valley (Indianapolis), South (Atlanta), and Southwest (Yuma)--were modeled using an ASPEN simulator model. The model evaluated the performance and energy penalty for hypothetical 400-MW coal-fired plants that were retrofitted from using once-through cooling systems to wet- and dry-recirculating systems. The modeling was initially done to simulate the hottest time of the year using temperature input values that are exceeded only 1 percent of the time between June through September at each modeled location. These are the same temperature inputs commonly used by cooling tower designers to ensure that towers perform properly under most climatic conditions.

Book The Scales of Weighing Regulatory Costs

Download or read book The Scales of Weighing Regulatory Costs written by Jamison E. Colburn and published by Edward Elgar Publishing. This book was released on 2018-11-30 with total page 291 pages. Available in PDF, EPUB and Kindle. Book excerpt: This book examines the calculation and evaluation of regulatory costs by regulators in accordance with a legislative mandate. A serious limitation in that enterprise, the possibility of technological change and innovation, often compromises those efforts and has long been under-appreciated in standard ‘cost-benefit analysis.’ Regulators who study the inducement of innovation and the avoidance of regulatory costs by the regulated often find significant cost-saving opportunities, leading to more stringent and more effective risk governance. Ultimately, the weighing of costs in this more elaborate model is more than simple welfare maximization. It views regulatory costs as important to society for a range of reasons, some grounded in fairness and some in deliberative process values, as a society seeks to minimize all costs over time.

Book EPA National Publications Catalog

Download or read book EPA National Publications Catalog written by United States. Environmental Protection Agency and published by . This book was released on 2003 with total page 222 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Notice of Data Availability for Proposed Regulations Establishing Location  Design  Construction and Capacity Standards for Cooling Water Intake Structures at New Facilities

Download or read book Notice of Data Availability for Proposed Regulations Establishing Location Design Construction and Capacity Standards for Cooling Water Intake Structures at New Facilities written by and published by . This book was released on 2001 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Environmental Water Account

Download or read book Environmental Water Account written by and published by . This book was released on 2007 with total page 364 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Cooling Water Intake Structures

Download or read book Cooling Water Intake Structures written by Claudia Copeland and published by . This book was released on 2011 with total page 26 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Cooling Water Intake Structures

Download or read book Cooling Water Intake Structures written by and published by . This book was released on 2013 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Federal Register

Download or read book Federal Register written by and published by . This book was released on 2014 with total page 570 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Notice of Data Availability for Proposed Regulations Establishing Location  Design  Construction and Capacity Standards for Cooling Water Intake Structures at Existing Facilities

Download or read book Notice of Data Availability for Proposed Regulations Establishing Location Design Construction and Capacity Standards for Cooling Water Intake Structures at Existing Facilities written by and published by . This book was released on 2003 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Potential Impacts of 316 B  Regulatory Controls on Economics  Electricity Reliability  and the Environment

Download or read book Potential Impacts of 316 B Regulatory Controls on Economics Electricity Reliability and the Environment written by and published by . This book was released on 1999 with total page 14 pages. Available in PDF, EPUB and Kindle. Book excerpt: Nearly half of the US utility-owned steam electric generating capacity is cooled by once-through cooling systems. These plants withdraw cooling water primarily from surface water bodies. Section 316(b) of the Clean Water Act requires that the location, design, construction, and capacity of cooling water intake structures reflect the best technology available (BTA) for minimizing adverse environmental impacts. At present, the US Environmental Protection Agency (EPA) has not yet promulgated applicable implementing regulations governing intake structures; however, the Agency is required by a Consent Decree to develop such regulations. EPA has presented a draft tiered regulatory framework approach that, depending on site-specific factors, may impose various regulatory burdens on affected utilities. Potential new requirements could range from compiling and submitting existing data to demonstrate that existing conditions at each unit represent BTA to retrofitting plants with closed-cycle cooling systems (primarily cooling towers). If the final regulations require installation of cooling towers or implementation of other costly plant modifications, utilities may elect to close some generating units rather than invest the finds necessary to upgrade them to meet the Section 316(b) requirements. Potentially, some regions of the country may then have a higher proportion of closed units than others, leading to a concern over the reliability of those regions' electricity supply. If a significant number of plants convert from once-through cooling systems to cooling towers, the environment will face secondary adverse impacts, such as additional fuel usage, air emissions, and water evaporation, and utilities will need to construct additional generating capacity. This paper describes a study that Argonne National Laboratory will conduct for the US Department of Energy to explore some of the potential outcomes of EPA's Section 316(b) regulatory process and their impact on economics, electricity supply reliability, and the environment.

Book Compass Port LLC Deepwater Port License Application

Download or read book Compass Port LLC Deepwater Port License Application written by and published by . This book was released on 2006 with total page 852 pages. Available in PDF, EPUB and Kindle. Book excerpt: