EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Comparative Linear Accuracy and Reliability of Cone Beam CT Derived 2 dimensional and 3 dimensional Images Constructed Using an Orthodontic Volumetric Rendering Program

Download or read book Comparative Linear Accuracy and Reliability of Cone Beam CT Derived 2 dimensional and 3 dimensional Images Constructed Using an Orthodontic Volumetric Rendering Program written by Danielle R. Periago and published by . This book was released on 2007 with total page 172 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of this project was to compare the accuracy and reliability of linear measurements made on 2D projections and 3D reconstructions using Dolphin 3D software (Chatsworth, CA) as compared to direct measurements made on human skulls. The linear dimensions between 6 bilateral and 8 mid-sagittal anatomical landmarks on 23 dentate dry human skulls were measured three times by multiple observers using a digital caliper to provide twenty orthodontic linear measurements. The skulls were stabilized and imaged via PSP digital cephalometry as well as CBCT. The PSP cephalograms were imported into Dolphin (Chatsworth, CA, USA) and the 3D volumetric data set was imported into Dolphin 3D (Version 2.3, Chatsworth, CA, USA).Using Dolphin 3D, planar cephalograms as well as 3D volumetric surface reconstructions were (3D CBCT) generated. The linear measurements between landmarks of each three modalities were then computed by a single observer three times. For 2D measurements, a one way ANOVA for each measurement dimension was calculated as well as a post hoc Scheffe multiple comparison test with the anatomic distance as the control group. 3D measurements were compared to anatomic truth using Student's t test (P [less than or equal to] 50.05). The intraclass correlation coefficient (ICC) and absolute linear and percentage error were determined as indices of intraobserver reliability. Our results show that for 2D mid sagittal measurements that Simulated LC images are accurate and similar to those from PSP images (except for Ba-Na), and for bilateral measurements simulated LC measurements were similar to PSP but less accurate, underestimating dimensions by between 4.7% to 17%.For 3D volumetric renderings, 2/3 rd of CBCT measurements are statistically different from actual measurements, however this possibly is not clinically relevant.

Book Cone Beam Computed Tomography in Orthodontics

Download or read book Cone Beam Computed Tomography in Orthodontics written by Sunil D. Kapila and published by John Wiley & Sons. This book was released on 2014-08-29 with total page 880 pages. Available in PDF, EPUB and Kindle. Book excerpt: Since its introduction to dentistry, cone beam computed tomography (CBCT) has undergone a rapid evolution and considerable integration into orthodontics. However, despite the increasing popularity of CBCT and progress in applying it to clinical orthodontics, the profession has lacked a cohesive, comprehensive and objective reference that provides clinicians with the background needed to utilize this technology optimally for treating their patients. Cone Beam Computed Tomography in Orthodontics provides timely, impartial, and state-of-the-art information on the indications and protocols for CBCT imaging in orthodontics, clinical insights gained from these images, and innovations driven by these insights. As such, it is the most current and authoritative textbook on CBCT in orthodontics. Cone Beam Computed Tomography in Orthodontics is organized to progress sequentially through specific topics so as to build the knowledgebase logically in this important and rapidly evolving field. Part I provides the foundational information on CBCT technology, including radiation exposure and risks, and future evolutions in computed tomography. Part II presents the Principles and Protocols for CBCT Imaging in Orthodontics, focusing on developing evidence-based criteria for CBCT imaging, the medico-legal implications of CBCT to the professional and the protocols and integration of this technology in orthodontic practice. Part III provides critical information on CBCT-based Diagnosis and Treatment Planning that includes how to interpret CBCT scans, identify incidental pathologies and the possible other uses of this technology. Part IV covers practical aspects of CBCT’s Clinical Applications and Treatment Outcomes that encompasses a range of topics, including root morphology and position, treatment of impacted teeth, virtual surgical treatment planning and outcomes, and more.

Book Craniofacial 3D Imaging

Download or read book Craniofacial 3D Imaging written by Onur Kadioglu and published by Springer. This book was released on 2019-01-28 with total page 251 pages. Available in PDF, EPUB and Kindle. Book excerpt: This book is designed to serve as an up-to-date reference on the use of cone-beam computed tomography for the purpose of 3D imaging of the craniofacial complex. The focus is in particular on the ways in which craniofacial 3D imaging changes how we think about conventional diagnosis and treatment planning and on its clinical applications within orthodontics and oral and maxillofacial surgery. Emphasis is placed on the value of 3D imaging in visualizing the limits of the alveolar bone, the airways, and the temporomandibular joints and the consequences for treatment planning and execution. The book will equip readers with the knowledge required in order to apply and interpret 3D imaging to the benefit of patients. All of the authors have been carefully selected on the basis of their expertise in the field. In describing current thinking on the merits of 3D craniofacial imaging, they draw both on the available scientific literature and on their own translational research findings.

Book CONE BEAM COMPUTED TOMOGRAPHY IN ORTHODONTICS

Download or read book CONE BEAM COMPUTED TOMOGRAPHY IN ORTHODONTICS written by Dr. SHREYA SHARMA and published by Book Rivers. This book was released on 2022-02-07 with total page 214 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Comparative Linear Accuracy and Reliability of Cone Beam CT Derived 2 dimensional Images and Conventional Lateral Cephalometric Images Using Photostimulable Storage Phosphors

Download or read book Comparative Linear Accuracy and Reliability of Cone Beam CT Derived 2 dimensional Images and Conventional Lateral Cephalometric Images Using Photostimulable Storage Phosphors written by Mazyar Moshiri and published by . This book was released on 2008 with total page 168 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of this project was to compare the accuracy and precision of linear measurements made on conventional lateral cephalograms (LC) and simulated LC using cone-beam computed tomography (CBCT) to direct measurements on dentate skulls. The linear distances for 5 mid-sagittal and 4 bilateral measurements between anatomical landmarks on 22 skulls were measured by two observers. The skulls were imaged using a CBCT scanner at 4 scan settings: high resolution (0.2mm) and normal resolution (0.4mm) at 20-sec (306 projections) and 40-sec scans (612 projections). Three simulated LC were generated: Ray sum image reconstructions of the maximum thickness mid-sagittal multiplanar projections, a single frame basis projection, and the scout image. LCs were acquired using a storage phosphor system. Projection images were exported into a cephalometric analysis program and linear measurements determined. Analyses were repeated three times and statistically compared to measured anatomic truth using repeated measures general linear model (p [less than or equal to] 0.05). The mean absolute error was used as an index of precision. While there were statistical differences between skull and modality measurements for 6 of the nine measurements, there were no overall differences between LC and CBCT derived image measurements irrespective of method of construction. CBCT imaging provides clinically reliable 2D simulation images however, dose considerations demand that evidence-based selection criteria should be developed for CBCT in orthodontics that take into account the ALARA principle.

Book Comparative Linear Accuracy of Cone Beam CT Derived 3D Images in Orthodontic Analysis

Download or read book Comparative Linear Accuracy of Cone Beam CT Derived 3D Images in Orthodontic Analysis written by April A. Brown and published by . This book was released on 2008 with total page 166 pages. Available in PDF, EPUB and Kindle. Book excerpt: Objective. To compare the in vitro reliability and accuracy of linear measurements between cephalometric landmarks on CBCT 3D images with varying basis projection images to direct measurements on human skulls. Methods. Sixteen linear dimensions between anatomical sites marked on 19 human skulls were directly measured. Skulls were imaged with CBCT at three settings: 153, 306, and 612 basis projections. The mean absolute error and modality mean of linear measurements between landmarks on 3D images were compared to the anatomic truth. Results. No difference in mean absolute error between the scan settings was found. The average skull absolute error between marked reference points were less than the distances between unmarked reference sites. Conclusion. CBCT measurements were consistent between scan sequences and for direct measurements between marked reference points. Reducing the number of projections for 3D reconstruction did not lead to reduced dimensional accuracy and potentially provides reduced patient radiation exposure.

Book Fundamentals of Musculoskeletal Imaging

Download or read book Fundamentals of Musculoskeletal Imaging written by Lynn N McKinnis and published by F.A. Davis. This book was released on 2013-12-26 with total page 732 pages. Available in PDF, EPUB and Kindle. Book excerpt: Here’s everything Physical Therapists need to know about medical imaging. This comprehensive guide helps you develop the skills and knowledge you need to accurately interpret imaging studies and understand written reports. Lynn McKinnis, 2009 winner of APTA’s Helen J. Hislop Award for Outstanding Contributions to Professional Literature, guides you every step of the way. Begin with a basic introduction to radiology; then progress to evaluating radiographs and advanced imaging from head to toe. Imaging for commonly seen traumas and pathologies, as well as case studies prepare you to meet the most common to complex challenges in clinical and practice.

Book Ultrasonography in Dentomaxillofacial Diagnostics

Download or read book Ultrasonography in Dentomaxillofacial Diagnostics written by Kaan Orhan and published by Springer Nature. This book was released on 2021-03-03 with total page 372 pages. Available in PDF, EPUB and Kindle. Book excerpt: This book offers a comprehensive review of the state of the art in Ultrasonography (USG) dentomaxillofacial imaging to help radiologists and dentists in their training and daily practice. The book examines the relationship between clinical features, diagnosis, and choice of minimally invasive technique for a range of dentomaxillofacial disorders and provides information on post-treatment therapy. Accurate interpretation of indications for treatment is the cornerstone of success in medicine, and as such, the book explains how the selection of imaging technique is closely linked to clinical and diagnostic aspects and how recognition of this relationship forms the foundation for optimal outcomes. In addition to examining the various modalities, the book highlights the role of the latest USG imaging techniques. Further, it discusses in detail the pathology, treatment, and prognosis of common and rare diseases, as well as congenital/developmental malformations in the dentomaxillofacial, an area that is often underestimated and largely ignored by dentists. Featuring updated high-resolution images created with state-of-the-art equipment, the book introduces readers to current imaging modalities. It also includes pathological descriptions of radiologic diagnoses to help clarify the pathophysiology of the disease, while the pearls and pitfalls of image interpretation provide a quick reference guide for practitioners. Written by leading international experts, this outstanding book is a valuable resource for both radiologists, dentists and students seeking a more in-depth appreciation of the subject and its contribution to the scientific radiology community.

Book Comparative Accuracy of Linear Measures from Conventional Digital and Cone Beam Computed Tomography Simulated Posterior Anterior Cephalograms

Download or read book Comparative Accuracy of Linear Measures from Conventional Digital and Cone Beam Computed Tomography Simulated Posterior Anterior Cephalograms written by Brian M. Mannari and published by . This book was released on 2007 with total page 152 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of this project was to compare the accuracy and reliability of linear measurements on posterior-anterior (PA) cephalograms made conventionally using photostimulable storage phosphor imaging plates (PSP) and simulated PA cephalometric images from ray sum reconstruction of cone beam computed tomographic (CBCT) volumetric datasets of the same anatomic specimens. The sample consisted of 19 dried dentate human skulls which were imaged using PA cephalometry using PSP imaging plates and three CBCT datasets at 10 s., 20 s. and 40 s. scanning times from which ray sum simulated PA images were produced. Various anatomic landmarks were identified and truth measurements of 13 selected cephalometric linear dimensions were measured directly on the skulls using a high precision caliper. CBCT datasets were imported into a reconstruction program (Dolphin 3D Software) from which ray sum PA images were constructed. Linear cephalometric measurements on PSP and CBCT simulated PA images were performed by one observer using Dolphin Imaging Software. Intraobserver reliability was determined by calculating and comparing Intraclass correlation coefficient. Mean absolute and percentage errors were calculated for each dimension and modality to quantify the reliability error. Mean modality measurements were compared. All other groups were compared using one-way ANOVA with Tukey post hoc comparisons (p [less than or equal to] 0.05). While the ICC was high, PSP cephalometric absolute error was greater than anatomic distances and CBCT image measurements for 8 for 13 measurements. We found that for most measurements, simulated PA images produced from reconstructed CBCT volumetric dataset were accurate and compared well to PSP cephalometric images except for Z-Ag. We also found that PSP cephalometric images consistently underestimated MO-MO dimensions. Measurements on CBCT simulated PA images are more reliabile and as accuracte as PSP cephalometric measurements. The number of projections comprising the reconstructed simulated PA image did not influence reliability or accuracy. Therefore in accordance with ALARA, when CBCT imaging is used to generate simulated PA images, the lowest number of projections are recommended.

Book 3D Diagnosis and Treatment Planning in Orthodontics

Download or read book 3D Diagnosis and Treatment Planning in Orthodontics written by Jean-Marc Retrouvey and published by Springer Nature. This book was released on 2021-03-13 with total page 325 pages. Available in PDF, EPUB and Kindle. Book excerpt: This richly illustrated book is a wide-ranging guide to modern diagnostics and treatment planning in orthodontics, which are mandatory prior to the initiation of any type of comprehensive treatment. The importance of three-dimensional (3D) imaging techniques has been increasingly recognized owing to the shortcomings of conventional two-dimensional imaging in some patients, such as those requiring complex adult treatment and those with temporomandibular joint dysfunctions or sleep disturbances. In the first part of this book, readers will find clear description and illustration of the diagnostic role of the latest 3D imaging techniques, including cone beam computed tomography, intra-oral scanning, and magnetic resonance imaging. The second part explains in detail the application of 3D techniques in treatment planning for orthodontic and orthognathic surgery. Guidance is also provided on the use of image fusion software for the purposes of accurate diagnosis and precise design of the most appropriate biomechanical approach in patients with malocclusions.

Book Cone Beam Computed Tomography  From Capture to Reporting  An Issue of Dental Clinics of North America

Download or read book Cone Beam Computed Tomography From Capture to Reporting An Issue of Dental Clinics of North America written by Dale A. Miles and published by Elsevier Health Sciences. This book was released on 2014-07-28 with total page 265 pages. Available in PDF, EPUB and Kindle. Book excerpt: This issue of Dental Clinics updates topics in CBCT and Dental Imaging. Articles will cover: basic principles of CBCT; artifacts interfering with interpretation of CBCT; basic anatomy in the three anatomic planes of section; endodontic applications of CBCT; pre-surgical implant site assessment; software tools for surgical guide construction; CBCT for the nasal cavity and paranasal sinuses; CBCT and OSA and sleep disordered breathing; update on CBCT and orthodontic analyses; liabilities and risks of using CBCT; reporting findings in a CBCT volume, and more!

Book Maxillofacial Cone Beam Computed Tomography

Download or read book Maxillofacial Cone Beam Computed Tomography written by William C. Scarfe and published by Springer. This book was released on 2018-01-04 with total page 1241 pages. Available in PDF, EPUB and Kindle. Book excerpt: The book provides a comprehensive description of the fundamental operational principles, technical details of acquiring and specific clinical applications of dental and maxillofacial cone beam computed tomography (CBCT). It covers all clinical considerations necessary for optimal performance in a dental setting. In addition overall and region specific correlative imaging anatomy of the maxillofacial region is described in detail with emphasis on relevant disease. Finally imaging interpretation of CBCT images is presented related to specific clinical applications. This book is the definitive resource for all who refer, perform, interpret or use dental and maxillofacial CBCT including dental clinicians and specialists, radiographers, ENT physicians, head and neck, and oral and maxillofacial radiologists.

Book Radiographic Cephalometry

Download or read book Radiographic Cephalometry written by Alexander Jacobson and published by Quintessence Publishing (IL). This book was released on 2006 with total page 326 pages. Available in PDF, EPUB and Kindle. Book excerpt: Accompanying CD-ROM contains ... "an 'average' template and larger and smaller 'normal' templates ... Also provided are instructions for the digital application of the templates to accommodate skulls of all sizes."--Page ix.

Book 3D Echocardiography

    Book Details:
  • Author : Takahiro Shiota
  • Publisher : CRC Press
  • Release : 2020-12-29
  • ISBN : 1000063526
  • Pages : 621 pages

Download or read book 3D Echocardiography written by Takahiro Shiota and published by CRC Press. This book was released on 2020-12-29 with total page 621 pages. Available in PDF, EPUB and Kindle. Book excerpt: Since the publication of the second edition of this volume, 3D echocardiography has penetrated the clinical arena and become an indispensable tool for patient care. The previous edition, which was highly commended at the British Medical Book Awards, has been updated with recent publications and improved images. This third edition has added important new topics such as 3D Printing, Surgical and Transcatheter Management, Artificial Valves, and Infective Endocarditis. The book begins by describing the principles of 3D echocardiography, then proceeds to discuss its application to the imaging of • Left and Right Ventricle, Stress Echocardiography • Left Atrium, Hypertrophic Cardiomyopathy • Mitral Regurgitation with Surgical and Nonsurgical Procedures • Mitral Stenosis and Percutaneous Mitral Valvuloplasty • Aortic Stenosis with TAVI / TAVR • Aortic and Tricuspid Regurgitation • Adult Congenital Heart Disease, Aorta • Speckle Tracking, Cardiac Masses, Atrial Fibrillation KEY FEATURES In-depth clinical experiences of the use of 3D/2D echo by world experts Latest findings to demonstrate clinical values of 3D over 2D echo One-click view of 263 innovative videos and 352 high-resolution 3D/2D color images in a supplemental eBook.

Book Orthodontic Pearls

    Book Details:
  • Author : Eliakim Mizrahi
  • Publisher : CRC Press
  • Release : 2015-04-01
  • ISBN : 1482241951
  • Pages : 428 pages

Download or read book Orthodontic Pearls written by Eliakim Mizrahi and published by CRC Press. This book was released on 2015-04-01 with total page 428 pages. Available in PDF, EPUB and Kindle. Book excerpt: Orthodontic Pearls: A Selection of Practical Tips and Clinical Expertise synthesizes a wealth of information gleaned from clinical and administrative experiences in orthodontic practice. The administration and running of an orthodontic practice is not often taught extensively or formally in most schools. This book fills that gap by providing tips,

Book Cone Beam CT and 3D imaging

    Book Details:
  • Author : Pietro Caruso
  • Publisher : Springer Science & Business Media
  • Release : 2013-09-24
  • ISBN : 8847053196
  • Pages : 159 pages

Download or read book Cone Beam CT and 3D imaging written by Pietro Caruso and published by Springer Science & Business Media. This book was released on 2013-09-24 with total page 159 pages. Available in PDF, EPUB and Kindle. Book excerpt: Cone beam computed tomography (CBCT) has become the standard of reference in dental imaging. The distribution of CBCT devices is increasingly wide, and the number of required examinations is constantly growing. In this setting, it is now essential that medical and technical staff receive specific training in the use of CBCT and that technical guidelines for CBCT examinations are established. This clearly structured book on CBCT will be an ideal aid in daily clinical practice. It clearly explains basic CBCT anatomy, examination technique, and the use of 3D reformatting software. A wide range of cases are presented, covering the most frequent and relevant conditions and pathologies, including dental anomalies, inflammatory and degenerative disease, tumors, and implants.