EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Systems Acceptance and Operability Testing for Rotary Mode Core Sampling in Flammable Gas Tanks

Download or read book Systems Acceptance and Operability Testing for Rotary Mode Core Sampling in Flammable Gas Tanks written by and published by . This book was released on 1996 with total page 53 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides instructions for the system acceptance and operability testing of the rotary mode core sampling system, modified for use in flammable gas tanks.

Book Tableaux  meubles  tapisseries

Download or read book Tableaux meubles tapisseries written by and published by . This book was released on 1901 with total page 12 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Operability Test Procedure for Rotary Mode Core Sampling System  number sign 4

Download or read book Operability Test Procedure for Rotary Mode Core Sampling System number sign 4 written by and published by . This book was released on 1995 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document gives instructions for the Operability Testing of the Rotary Mode Core Sampling (RMCS) System No. 4. This document is based on the Operability Test Procedure for RMCS system No. 2 because the basic design is the same for all three systems. Modifications have been made from the original design only when exact duplication was not feasible or design improvements could be incorporated without affecting the operation of the system. Operability testing of the Rotary Mode Core Sampling System No. 4 will verify that functional and operational requirements have been met. Testing will be completed in two phases. The first phase of testing (section 7) will involve operating the truck equipment to demonstrate its capabilities. The second phase of testing (section 8) will take repeated samples in a simulated operation environment. These tests will be conducted at the ''Rock Slinger'' test site located just south of U-Plant in the 200 West Area. Tests will be done in a simulated tank farm environment. All testing will be non-radioactive and stand-in materials shall be used to simulate waste tank conditions. Systems will be assembled and arranged in a manner similar to that expected in the field.

Book Operability Test Procedure for Rotary Mode Core Sampling System  number sign 3

Download or read book Operability Test Procedure for Rotary Mode Core Sampling System number sign 3 written by and published by . This book was released on 1995 with total page 70 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document gives instructions for the Operability Testing of the Rotary Mode Core Sampling (RMCS) System No. 3. This document is based on the Operability Test Procedure for RMCS system No. 2 because the basic design is the same for all three systems. Modifications have been made from the original design only when exact duplication was not feasible or design improvements could be incorporated without affecting the operation of the system. Operability testing of the Rotary Mode Core Sampling System No. 3, will verify that functional and operational requirements have been met. Testing will be completed in two phases. The first phase of testing (section 7) will involve operating the truck equipment to demonstrate its capabilities. The second phase of testing (section 8) will take repeated samples in a simulated operation environment. These tests will be conducted at the ''Rock Slinger'' test site located just south of U-Plant in the 200 West Area. Tests will be done in a simulated tank farm environment. All testing will be non-radioactive and stand-in materials shall be used to simulate waste tank conditions. Systems will be assembled and arranged in a manner similar to that expected in the field.

Book Operability Test Procedure for Rotary Mode Core Sampling System  3

Download or read book Operability Test Procedure for Rotary Mode Core Sampling System 3 written by and published by . This book was released on 1995 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Operability Test Procedure for the Rotary Mode Core Sampling System Exhausters 3 and 4

Download or read book Operability Test Procedure for the Rotary Mode Core Sampling System Exhausters 3 and 4 written by and published by . This book was released on 1995 with total page 30 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides a procedure for performing operability testing of the Rotary Mode Core Sampling System Exhausters 3 & 4. Upon completion of testing activities an operability testing report will be issued.

Book Operability Test Procedure for Rotary Mode Core Sampling System  4

Download or read book Operability Test Procedure for Rotary Mode Core Sampling System 4 written by and published by . This book was released on 1995 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Operability Test Report for Rotary Mode Core Sampling System Number 3

Download or read book Operability Test Report for Rotary Mode Core Sampling System Number 3 written by and published by . This book was released on 1996 with total page 110 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report documents the successful completion of operability testing for the Rotary Mode Core Sampling (RMCS) system {number_sign}3. The Report includes the test procedure (WHC-SD-WM-OTP-174), exception resolutions, data sheets, and a test report summary.

Book Rotary Mode Core Sampling Approved Checklist

Download or read book Rotary Mode Core Sampling Approved Checklist written by and published by . This book was released on 1998 with total page 24 pages. Available in PDF, EPUB and Kindle. Book excerpt: The safety assessment for rotary mode core sampling was developed using certain bounding assumptions, however, those assumptions were not verified for each of the existing or potential flammable gas tanks. Therefore, a Flammable Gas/Rotary Mode Core Sampling Approved Checklist has been completed for tank 241-TX-113 prior to sampling operations. This transmittal documents the dispositions of the checklist items from the safety assessment.

Book Acceptance Test Procedures for Rotary Mode Core Sampling Exhausters

Download or read book Acceptance Test Procedures for Rotary Mode Core Sampling Exhausters written by and published by . This book was released on 1995 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Testing to Expand the Rotary Mode Core Sampling System Operating Envelope

Download or read book Testing to Expand the Rotary Mode Core Sampling System Operating Envelope written by and published by . This book was released on 1998 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt: Rotary sampling using the Rotary Mode Core Sampling System (RMCSS) is constrained by what is referred to as the ''Operating Envelope''. The Operating Envelop defines the maximum downward force, maximum rotational speed and minimum purge gas flow allowed during operation of the RMCSS. The original values of 1170 lb. down force, 55 RPM rotational speed, and 30 SCFM nitrogen purge gas were determined during original envelope testing. This envelope was determined by observing the temperature rise on the bitface while drilling into waste simulants. The maximum temperature in single-shell tanks (SSTS) is considered to be approximately 9O C and the critical drill bit temperature, which is the temperature at which an exothermic reaction could be initiated in the tank waste, was previously determined to be 150 C. Thus, the drill bit temperature increase was limited to 60 C. Thermal properties of these simulants approximated typical properties of waste tank saltcake. Later, more detailed envelope testing which used a pumice block simulant, showed a notably higher temperature rise while drilling. This pumice material, which simulated a ''worst case'' foreign object embedded in the waste, has lower thermal conductivity and lower thermal diffusivity than earlier simulants. These properties caused a slower heat transfer in the pumice than in the previous simulants and consequently a higher temperature rise. The maximum downward force was subsequently reduced to 750 lb (at a maximum 55 RPM and minimum 30 SCFM purge gas flow) which was the maximum value at which the drill bit could be operated and still remain below the 60 C temperature rise.

Book Report on Testing to Expand the Rotary Mode Core Sampling Operating Envelope

Download or read book Report on Testing to Expand the Rotary Mode Core Sampling Operating Envelope written by and published by . This book was released on 1999 with total page 203 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Tank Waste Remediation System (TWRS) Characterization Equipment Group requested that the Numatec Hanford Corporation--Engineering Testing Laboratory (ETL) perform Rotary Mode Core Sampling (RMCS) Operating Envelope (OE) testing. This testing was based upon Witwer 1998a and was performed at different time periods between May and September 1998. The purpose of this testing was to raise the maximum down force limit for rotary mode core sampling as outlined in the current OE. If testing could show that a higher down force could be used while drilling into a concrete/pumice block simulant while still remaining below the 60 C limitation, then the current OE could be revised to include the new, higher, down force limit. Although the Test Plan discussed varying the purge flow rate and rotation rate to find ''optimal'' drilling conditions, the number of drill bits that could be destructively tested was limited. Testing was subsequently limited in scope such that only the down force would be varied while the purge flow rate and rotation rate were kept constant at 30 scfm and 55 rpm respectively. A second objective, which was not part of the original test plan, was added prior to testing. The Bit Improvement testing, mentioned previously, revealed that the drill bits tested in the OE testing were made of a slightly different metal matrix than the ones currently used. The older bits, a Longyear part number 100IVD/5 (/5 bit), had tungsten carbide mixed into the metal matrix that forms the cutting teeth. The currently used bits, Longyear part number 100IVD/8 (/8 bit), instead have tungsten metal in the matrix and no tungsten carbide. Rockwell C hardness testing showed that the /5 bit was significantly harder than the /8 bit, with values of /8 vs. 8, respectively. The change from the /5 bit to the /8 bit was made immediately after the previous OE testing in 1996 because of sparking concerns with the tungsten carbide in the /5 bit. This difference in hardness between the two bit materials was discovered in the Bit Improvement Testing and was expected to affect this OE testing. The second objective, therefore, was to quantify what affect this change in material had and define the OE, based on the current /8 bit design rather than the old /5 bit design.

Book Energy Research Abstracts

Download or read book Energy Research Abstracts written by and published by . This book was released on 1995 with total page 832 pages. Available in PDF, EPUB and Kindle. Book excerpt: Semiannual, with semiannual and annual indexes. References to all scientific and technical literature coming from DOE, its laboratories, energy centers, and contractors. Includes all works deriving from DOE, other related government-sponsored information, and foreign nonnuclear information. Arranged under 39 categories, e.g., Biomedical sciences, basic studies; Biomedical sciences, applied studies; Health and safety; and Fusion energy. Entry gives bibliographical information and abstract. Corporate, author, subject, report number indexes.

Book Rotary Mode Core Sampling Service Trailer Acceptance Test Plan

Download or read book Rotary Mode Core Sampling Service Trailer Acceptance Test Plan written by and published by . This book was released on 1994 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Rotary Mode Core Sampling Approved Checklist

Download or read book Rotary Mode Core Sampling Approved Checklist written by and published by . This book was released on 1999 with total page 22 pages. Available in PDF, EPUB and Kindle. Book excerpt: The safety assessment for rotary mode core sampling was developed using certain bounding assumptions, however, those assumptions were not verified for each of the existing or potential flammable gas tanks. Therefore, a Flammable Gas/Rotary Mode Core Sampling Approved Checklist has been completed for tank 241-TX-116 prior to sampling operations. This transmittal documents the dispositions of the checklist items from the safety assessment.

Book INIS Atomindex

Download or read book INIS Atomindex written by and published by . This book was released on 1995 with total page 682 pages. Available in PDF, EPUB and Kindle. Book excerpt: