EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Results from Plasma Wakefield Experiments at FACET

Download or read book Results from Plasma Wakefield Experiments at FACET written by and published by . This book was released on 2011 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: We report initial results of the Plasma Wakefield Acceleration (PWFA) Experiments performed at FACET - Facility for Advanced aCcelertor Experimental Tests at SLAC National Accelerator Laboratory. At FACET a 23 GeV electron beam with 1.8 x 101° electrons is compressed to 20 [mu]m longitudinally and focused down to 10 [mu]m x 10 [mu]m transverse spot size for user driven experiments. Construction of the FACET facility completed in May 2011 with a first run of user assisted commissioning throughout the summer. The first PWFA experiments will use single electron bunches combined with a high density lithium plasma to produce accelerating gradients> 10 GeV/m benchmarking the FACET beam and the newly installed experimental hardware. Future plans for further study of plasma wakefield acceleration will be reviewed. The experimental hardware and operation of the plasma heat-pipe oven have been successfully commissioned. Plasma wakefield acceleration was not observed because the electron bunch density was insufficient to ionize the lithium vapor. The remaining commissioning time in summer 2011 will be dedicated to delivering the FACET design parameters for the experimental programs which will begin in early 2012. PWFA experiments require the shorter bunches and smaller transverse sizes to create the plasma and drive large amplitude wakefields. Low emittance and high energy will minimize head erosion which was found to be a limiting factor in acceleration distance and energy gain. We will run the PWFA experiments with the design single bunch conditions in early 2012. Future PWFA experiments at FACET are discussed in [5][6] and include drive and witness bunch production for high energy beam manipulation, ramped bunch to optimize tranformer ratio, field-ionized cesium plasma, preionized plasmas, positron acceleration, etc. We will install a notch collimator for two-bunch operation as well as new beam diagnostics such as the X-band TCAV [7] to resolve the two bunches. With these new instruments and desired beam parameters in place next year, we will be able to complete the studies of plasma wakefield acceleration in the next few years.

Book Plasma Wakefield Experiments at FACET

Download or read book Plasma Wakefield Experiments at FACET written by and published by . This book was released on 2011 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to ≈20[mu]m long and focused to ≈10[mu]m wide. The intense fields of the FACET bunches will be used to field ionize neutral lithium or cesium vapor produced in a heat pipe oven. Previous experiments at the SLAC FFTB facility demonstrated 50GeV/m gradients in an 85cm field ionized lithium plasma where the interaction distance was limited by head erosion. Simulations indicate the lower ionization potential of cesium will decrease the rate of head erosion and increase single stage performance. The initial experimental program will compare the performance of lithium and cesium plasma sources with single and double bunches. Later experiments will investigate improved performance with a pre-ionized cesium plasma. The status of the experiments and expected performance are reviewed. The FACET Facility is being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration. The facility will begin commissioning in summer 2011 and conduct an experimental program over the coming five years to study electron and positron beam driven plasma acceleration with strong wake loading in the non-linear regime. The FACET experiments aim to demonstrate high-gradient acceleration of electron and positron beams with high efficiency and negligible emittance growth.

Book Results From Plasma Wakefield Acceleration Experiments at FACET

Download or read book Results From Plasma Wakefield Acceleration Experiments at FACET written by and published by . This book was released on 2014 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Preliminary Simulations of Plasma Wakefield Accelerator Experiments at FACET

Download or read book Preliminary Simulations of Plasma Wakefield Accelerator Experiments at FACET written by and published by . This book was released on 2016 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Plasma Wakefield Acceleration and FACET   Facilities for Accelerator Science and Experimental Test Beams at SLAC

Download or read book Plasma Wakefield Acceleration and FACET Facilities for Accelerator Science and Experimental Test Beams at SLAC written by and published by . This book was released on 2009 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Plasma wakefield acceleration is one of the most promising approaches to advancing accelerator technology. This approach offers a potential 1,000-fold or more increase in acceleration over a given distance, compared to existing accelerators. FACET, enabled by the Recovery Act funds, will study plasma acceleration, using short, intense pulses of electrons and positrons. In this lecture, the physics of plasma acceleration and features of FACET will be presented.

Book Latest Plasma Wakefield Acceleration Results from the FACET Project

Download or read book Latest Plasma Wakefield Acceleration Results from the FACET Project written by and published by . This book was released on 2014 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Status of Plasma Electron Hose Instability Studies in FACET

Download or read book Status of Plasma Electron Hose Instability Studies in FACET written by and published by . This book was released on 2011 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: In the FACET plasma-wakefield acceleration experiment a dense 23 GeV electron beam will interact with lithium and cesium plasmas, leading to plasma ion-channel formation. The interaction between the electron beam and the plasma sheath-electrons may lead to a fast growing electron hose instability. By using optics dispersion knobs to induce a controlled z-x tilt along the beam entering the plasma, we investigate the transverse behavior of the beam in the plasma as function of the tilt. We seek to quantify limits on the instability in order to further explore potential limitations on future plasma wakefield accelerators due to the electron hose instability. The FACET plasma-wakefield experiment at SLAC will study beam driven plasma wakefield acceleration. A dense 23 GeV electron beam will interact with lithium or cesium plasma, leading to plasma ion-channel formation. The interaction between the electron beam and the plasma sheath-electrons drives the electron hose instability, as first studied by Whittum. While Ref. [2] indicates the possibility of a large instability growth rate for typical beam and plasma parameters, other studies including have shown that several physical effects may mitigate the hosing growth rate substantially. So far there has been no quantitative benchmarking of experimentally observed hosing in previous experiments. At FACET we aim to perform such benchmarking by for example inducing a controlled z-x tilt along the beamentering the plasma, and observing the transverse behavior of the beam in the plasma as function. The long-term objective of these studies is to quantify potential limitations on future plasma wakefield accelerators due to the electron hose instability.

Book Facility for Advanced Accelerator Experimental Tests  FACET  at SLAC and Its Radiological Considerations

Download or read book Facility for Advanced Accelerator Experimental Tests FACET at SLAC and Its Radiological Considerations written by and published by . This book was released on 2011 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: Facility for Advanced Accelerator Experimental Tests (FACET) in SLAC will be used to study plasma wakefield acceleration. FLUKA Monte Carlo code was used to design a maze wall to separate FACET project and LCLS project to allow persons working in FACET side during LCLS operation. Also FLUKA Monte Carlo code was used to design the shielding for FACET dump to get optimum design for shielding both prompt and residual doses, as well as reducing environmental impact. FACET will be an experimental facility that provides short, intense pulses of electrons and positrons to excite plasma wakefields and study a variety of critical issues associated with plasma wakefield acceleration [1]. This paper describes the FACET beam parameters, the lay-out and its radiological issues.

Book Plasmas  Dielectrics and the Ultrafast

Download or read book Plasmas Dielectrics and the Ultrafast written by and published by . This book was released on 2012 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt: FACET (Facility for Advanced Accelerator and Experimental Tests) is an accelerator R & D test facility that has been recently constructed at SLAC National Accelerator Laboratory. The facility provides 20 GeV, 3 nC electron beams, short (20?m) bunches and small (20?m wide) spot sizes, producing uniquely high power beams. FACET supports studies from many fields but in particular those of Plasma Wakefield Acceleration and Dielectric Wakefield Acceleration. FACET is also a source of THz radiation for material studies. We present the FACET design, initial operating experience and first science from the facility.

Book Experimental Investigations of Beam Driven Plasma Wakefield Accelerators

Download or read book Experimental Investigations of Beam Driven Plasma Wakefield Accelerators written by Navid Vafaei-Najafabadi and published by . This book was released on 2016 with total page 156 pages. Available in PDF, EPUB and Kindle. Book excerpt: A plasma wakefield accelerator (PWFA) uses a plasma wave (a wake) to accelerate electrons at a gradient that is three orders of magnitude higher than that of a conventional accelerator. When the plasma wave is driven by a high-density particle beam or a high-intensity laser pulse, it evolves into the nonlinear blowout regime, where the driver expels the background plasma electrons, resulting in an ion cavity forming behind the driver. This ion cavity has ideal properties for accelerating and focusing electrons. One method to insert electrons into this highly-relativistic, transient structure is by ionization injection. In this method, electrons resulting from further ionization of the ions inside the wake are trapped and accelerated by the wakefield. These injected electrons absorb the energy of the wake, resulting in a reduced accelerating field amplitude; this phenomenon is known as beam loading. This thesis discusses experiments that demonstrate how ionization injection can, on the one hand, lead to excessive beam loading and be a detriment to a PWFA, while on the other hand, it may be taken advantage of to produce bright electron beams that will be necessary for applications of a PWFA to a free electron laser (FEL) or a collider. These experiments were part of the FACET Campaign at the SLAC National Accelerator Laboratory and used FACET's 3 nC, 20.35 GeV electron beam to field ionize the plasma source and drive a wake. In the first experiment, the plasma source was a 30 cm column of rubidium (Rb) vapor. The low ionization potential and high atomic mass of Rb made it a suitable candidate as a plasma source for a PWFA. However, the low ionization potential of the Rb+ ion resulted in continuous ionization of Rb+ and injection of electrons along the length of the plasma. This resulted in heavy beam-loading, which reduced the strength of the accelerating field by half, making the Rb source unusable for a PWFA. In the second experiment, the plasma source was a column of lithium (Li) vapor bound by cold helium (He) gas. Here, the ionization injection of He electrons in the 10 cm boundary region between Li and He led to localized beam loading and resulted in an accelerated electron beam with high energy (32 GeV), a 10% energy spread, and an emittance an order of magnitude smaller than the drive beam. Particle-in-cell simulations indicate that the beam loading can be further optimized by reducing the injection region even more, which can lead to bright, high-current, low-energy-spread electron beams.

Book Preliminary Conceptual Design Report for the FACET II Project at SLAC National Accelerator Laboratory

Download or read book Preliminary Conceptual Design Report for the FACET II Project at SLAC National Accelerator Laboratory written by and published by . This book was released on 2016 with total page 287 pages. Available in PDF, EPUB and Kindle. Book excerpt: Plasma wakefield acceleration has the potential to dramatically shrink the size and cost of particle accelerators. Research at the SLAC National Accelerator Laboratory has demonstrated that plasmas can provide 1,000 times the acceleration in a given distance compared with current technologies. Developing revolutionary and more efficient acceleration techniques that allow for an affordable high-energy collider is the focus of FACET, a National User Facility at SLAC. The existing FACET National User Facility uses part of SLAC’s two-mile-long linear accelerator to generate high-density beams of electrons and positrons. FACET-II is a new test facility to develop advanced acceleration and coherent radiation techniques with high-energy electron and positron beams. It is the only facility in the world with high energy positron beams. FACET-II provides a major upgrade over current FACET capabilities and the breadth of the potential research program makes it truly unique. It will synergistically pursue accelerator science that is vital to the future of both advanced acceleration techniques for High Energy Physics, ultra-high brightness beams for Basic Energy Science, and novel radiation sources for a wide variety of applications. The design parameters for FACET-II are set by the requirements of the plasma wakefield experimental program. To drive the plasma wakefield requires a high peak current, in excess of 10kA. To reach this peak current, the electron and positron design bunch size is 10? by 10? transversely with a bunch length of 10?. This is more than 200 times better than what has been achieved at the existing FACET. The beam energy is 10 GeV, set by the Linac length available and the repetition rate is up to 30 Hz. The FACET-II project is scheduled to be constructed in three major stages. Components of the project discussed in detail include the following: electron injector, bunch compressors and linac, the positron system, the Sector 20 sailboat and W chicanes, and experimental area and infrastructure.

Book Optics Design for FACET

Download or read book Optics Design for FACET written by and published by . This book was released on 2009 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt: FACET is a proposed facility at SLAC National Accelerator Laboratory. It will provide high energy, tightly focused and compressed electron and positron bunches for beam driven plasma wakefield acceleration research and other experiments. FACET will be built in the SLAC linac sector 20, where it will be separated from the LCLS located immediately downstream and will take advantage of the upstream 2 km linac for up to 23 GeV beam acceleration. FACET will also include an upgrade to linac sector 10, where a new e+ compressor chicane will be installed. The sector 20 will contain a new optics consisting of two chicanes for e+ and ebunch length compression, a final focus and an experimental line with a dump. The e+ and e- chicanes will allow the transport of e+ and ebunches together, their compression and proper positioning of e+ witness bunch behind the e- drive bunch at the plasma Interaction Point. The new optics will mostly use the existing SLAC magnets to minimize the project cost. Details of the FACET optics design and results of particle tracking simulations are presented.

Book Studies of Proton Driven Plasma Wakefield Acceleration

Download or read book Studies of Proton Driven Plasma Wakefield Acceleration written by Yangmei Li and published by Springer Nature. This book was released on 2020-07-15 with total page 140 pages. Available in PDF, EPUB and Kindle. Book excerpt: This thesis focuses on a cutting-edge area of research, which is aligned with CERN's mainstream research, the "AWAKE" project, dedicated to proving the capability of accelerating particles to the energy frontier by the high energy proton beam. The author participated in this project and has advanced the plasma wakefield theory and modelling significantly, especially concerning future plasma acceleration based collider design. The thesis addresses electron beam acceleration to high energy whilst preserving its high quality driven by a single short proton bunch in hollow plasma. It also demonstrates stable deceleration of multiple proton bunches in a nonlinear regime with strong resonant wakefield excitation in hollow plasma, and generation of high energy and high quality electron or positron bunches. Further work includes the assessment of transverse instabilities induced by misaligned beams in hollow plasma and enhancement of the wakefield amplitude driven by a self-modulated long proton bunch with a tapered plasma. This work has major potential to impact the next generation of linear colliders and also in the long-term may help develop compact accelerators for use in industrial and medical facilities.

Book Emittance Preservation in a Plasma Wakefield Accelerator

Download or read book Emittance Preservation in a Plasma Wakefield Accelerator written by Yujian Zhao and published by . This book was released on 2023 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: Plasma-based acceleration (PBA) is being considered as the basis for a future linear collider,where electrons and positron bunches must collide with extremely small spot sizes. In order to be focused to such spot sizes the beams must have extremely small emittances. Thus one challenge to a PBA collider is preserving the emittance of the accelerated beams. In this dissertation, the evolution and preservation of the witness beam emittance in aplasma-based accelerator in the nonlinear blowout regime is investigated using theory and particle-in-cell simulations. It it found that the use of plasma density ramps as matching sections are beneficial for emittance emittance growth mitigation and preservation even when the witness beam is focused so tightly within the plasma that its space charge force pulls ions inwards within the beam. In order to study the evolution of a beam in the wakefield, details of the motion ofa single beam particle in the accelerating and focusing fields of a nonlinear wakefield are presented. The exact solution to the transverse equation of motion of a single beam particle under the assumption of adiabatic acceleration is derived. Approximate and thus simpler solutions are provided under the assumptions that plasma density also changes adiabatically. Some important concepts, including the beam's envelope equation, geometric emittance, normalized emittance, single and beam C-S parameters, transport matrices, and matching are reviewed and elaborated upon. Emittance evolution and the importance of matching are discussed in the context of a uniform plasma. Using the approximate solution (WKB solution) of a single particle's motion, analyticalexpressions for the evolution of the beam emittance and the C-S parameters in an arbitrary adiabatic plasma profile are provided neglecting the acceleration of the beam inside the plasma. It is shown that the beam emittance can be preserved when the beams C-S parameters are matched to the entrance of the density profile even when the beam has an initial energy spread. It is also shown that the emittance growth for an unmatched beam is minimized when it is focused to the same vacuum plane as for a matched beam. The emittance evolution without ion motion is studied using 3D particle-in-cell QuickPIC simulation and the results agree well with the theoretical predictions. In some of the proposed experiments for the recently commissioned FACET II facility,the matching condition may not be perfectly satisfied and the wake may not be perfectly symmetric. It is shown that for a given set of beam parameters that are consistent with FACET II capabilities, the emittance growth can still be minimized by choosing the optimal focal plane even when the assumptions of the theory are not satisfied. Additional considerations for FACET II experiments were investigated. The plasma source is a lithium plasma confined by a helium buffer gas. The plasma is formed from field ionization which can lead to a nonlinear focusing force inside the helium buffer gas due to its high ionization potential leading to a nonuniform transverse profile for the plasma. It is found in simulations that for an initial beam emittance of 20 [mu]m, the helium ionization is found to be small and the witness beam's emittance can still be preserved. Emittance evolution for beam and plasma parameters relevant to a single stage of amulti-staged plasma-based linear collider (LC) is investigated. In some plasma-based LC designs the transverse space charge forces for extreme accelerating beam parameters are expected to pull background ions into the beam which can lead to longitudinally varying nonlinear focusing forces and result in emittance growth of the beam. To mitigate this, the use of an adiabatic plasma density ramp as a matching section is proposed and examined using theory and PIC simulations. The witness beam is matched to the low density plasma entrance, where the beam initially has a large matched spot size so the ion motion effects are relatively small. As the beam propagates in the plasma density upramp (downramp), it is adiabatically focused (defocused) and its phase space distribution evolves slowly towards an equilibrium distribution including the effects of the adiabatically changing ion motion. Simulation results from QPAD, a new quasi-3D, quasi-static PIC code, show that within a single acceleration stage, this concept can limit the projected emittance growth to only ∼2% for a 25 GeV, 100 nm emittance witness beam and ∼20% for a 100 GeV, 100 nm emittance witness beam. The trade-off between the adiabaticity of the plasma density ramp and the initial ion motion at the entrance for a given length of the plasma density ramp is also discussed. Additional issues for building a plasma based linear collider are discussed. Preliminaryparticle-in-cell simulation results which examine and illustrate problems like staging, shaped witness beam (for improved beam loading), emittance growth and hosing of a witness beam with an initial offset, ion motion triggered by the driver, and asymmetric witness beams are presented. The implications of these issues on a plasma based linear collider are discussed. Simulation results for witness beams with initial energy of 500 GeV such as would exist in a final stage of a PBA linear collider or an afterburner are presented.

Book Experimental  Theoretical and Computational Studies of Plasma Based Concepts for Future High Energy Accelerators

Download or read book Experimental Theoretical and Computational Studies of Plasma Based Concepts for Future High Energy Accelerators written by and published by . This book was released on 2013 with total page 14 pages. Available in PDF, EPUB and Kindle. Book excerpt: This is the final report on the DOE grant number DE-FG02-92ER40727 titled, "Experimental, Theoretical and Computational Studies of Plasma-Based Concepts for Future High Energy Accelerators." During this grant period the UCLA program on Advanced Plasma Based Accelerators, headed by Professor C. Joshi has made many key scientific advances and trained a generation of students, many of whom have stayed in this research field and even started research programs of their own. In this final report however, we will focus on the last three years of the grant and report on the scientific progress made in each of the four tasks listed under this grant. Four tasks are focused on: Plasma Wakefield Accelerator Research at FACET, SLAC National Accelerator Laboratory, In House Research at UCLA's Neptune and 20 TW Laser Laboratories, Laser-Wakefield Acceleration (LWFA) in Self Guided Regime: Experiments at the Callisto Laser at LLNL, and Theory and Simulations. Major scientific results have been obtained in each of the four tasks described in this report. These have led to publications in the prestigious scientific journals, graduation and continued training of high quality Ph. D. level students and have kept the U.S. at the forefront of plasma-based accelerators research field.

Book IMPROVEMENTS FOR THE THIRD GENERATION PLASMA WAKEFIELD EXPERIMENT E 164 AT SLAC

Download or read book IMPROVEMENTS FOR THE THIRD GENERATION PLASMA WAKEFIELD EXPERIMENT E 164 AT SLAC written by and published by . This book was released on 2004 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt: The E-164 experiment at the Stanford Linear Accelerator Center is the third in a series investigating Plasma Wakefield Acceleration where the wake is driven by electron bunches. A collaboration between SLAC, UCLA and USC, E-164 has up to 2 x 101° electrons at 28.5 GeV in 100 micron long bunches. These bunches enter a 30cm long Lithium plasma with density of 6 x 1015 electrons/cm3, where the transfer of energy from the head of the bunch to the tail takes place. In addition to acceleration, strong focusing, refraction of the electron beam and ''betatron X-ray'' production are all investigated. E-164 builds on related prior experiments, and its apparatus has evolved considerably. A third Optical Transition Radiator has been added for real time Twiss Parameter measurements which include the effects of scattering. The plasma cell is moved to the focus of the Final Focus Test Beam facility in order to increase bunch electron density. Spectrometry is extended with an upstream chicane in a dispersive region to produce synchrotron X-rays. Performance of these improvements and status of the experiment are discussed.

Book Evaluation of Temporal Diagnostic Techniques for Two Bunch Facet Beam

Download or read book Evaluation of Temporal Diagnostic Techniques for Two Bunch Facet Beam written by and published by . This book was released on 2011 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 [mu]m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 [mu]m and 30 [mu]m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.