EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Performance of 3 9 GHz SRF Cavities at Fermilab s ILCTA MDB Nhorizontal Test Stand

Download or read book Performance of 3 9 GHz SRF Cavities at Fermilab s ILCTA MDB Nhorizontal Test Stand written by and published by . This book was released on 2008 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt: Fermilab is building a cryomodule containing four 3.9 GHz superconducting radio frequency (SRF) cavities for the Free electron LASer in Hamburg (FLASH) facility at the Deutsches Elektronen-SYnchrotron (DESY) laboratory. Before assembling the cavities into the cryomodule, each individual cavity is tested at Fermilab's Horizontal Test Stand (HTS). The HTS provides the capability to test fully-dressed SRF cavities at 1.8 K with high-power pulsed RF in order to verify that the cavities achieve performance requirements under these conditions. The performance at the HTS of the 3.9 GHz cavities built for FLASH is presented here.

Book 1 3 GHz Superconducting RF Cavity Program at Fermilab

Download or read book 1 3 GHz Superconducting RF Cavity Program at Fermilab written by and published by . This book was released on 2011 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: At Fermilab, 9-cell 1.3 GHz superconducting RF (SRF) cavities are prepared, qualified, and assembled into cryomodules (CMs) for Project X, an International Linear Collider (ILC), or other future projects. The 1.3 GHz SRF cavity program includes targeted R & D on 1-cell 1.3 GHz cavities for cavity performance improvement. Production cavity qualification includes cavity inspection, surface processing, clean assembly, and one or more cryogenic low-power CW qualification tests which typically include performance diagnostics. Qualified cavities are welded into helium vessels and are cryogenically tested with pulsed high-power. Well performing cavities are assembled into cryomodules for pulsed high-power testing in a cryomodule test facility, and possible installation into a beamline. The overall goals of the 1.3 GHz SRF cavity program, supporting facilities, and accomplishments are described.

Book RF and Data Acquisition Systems for Fermilab s ILC SRF Cavity Vertical Test Stand

Download or read book RF and Data Acquisition Systems for Fermilab s ILC SRF Cavity Vertical Test Stand written by and published by . This book was released on 2007 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Fermilab is developing a facility for vertical testing of SRF cavities as part of a program to improve cavity performance reproducibility for the ILC. The RF system for this facility, using the classic combination of oscillator, phase detector/mixer, and loop amplifier to detect the resonant cavity frequency and lock onto the cavity, is based on the proven production cavity test systems used at Jefferson Lab for CEBAF and SNS cavity testing. The design approach is modular in nature, using commercial-off-the-shelf (COTS) components. This yields a system that can be easily debugged and modified, and with ready availability of spares. Data acquisition and control is provided by a PXI-based hardware platform in conjunction with software developed in the LabView programming environment. This software provides for amplitude and phase adjustment of incident RF power, and measures all relevant cavity power levels, cavity thermal environment parameters, as well as field emission-produced radiation. It also calculates the various cavity performance parameters and their associated errors. Performance during system commissioning and initial cavity tests will be presented.

Book Development of the Superconducting 3 9 GHz Accelerating Cavity at Fermilab

Download or read book Development of the Superconducting 3 9 GHz Accelerating Cavity at Fermilab written by H. Carter and published by . This book was released on 2005 with total page 3 pages. Available in PDF, EPUB and Kindle. Book excerpt: A superconducting third harmonic 3.9 GHz accelerating cavity was proposed to improve the beam quality in the TTF-like photoinjector [1]. Fermilab has developed, built and tested several prototypes, including two copper 9-cell cavities, one niobium 3-cell cavity, and one 9-cell cavity. The helium vessel and frequency tuner for the 9-cell cavity was built and tested as well. In cold tests, we achieved a peak surface magnetic field of {approx}100mT, well above the 70mT specification. The accelerating gradient was likely limited by thermal breakdown. Studies of the higher order modes in the cavity revealed that the existing cavity design with two HOM couplers will provide sufficient damping of these modes. In this paper we discuss the cavity design, results of the studies and plans for further development.

Book Resonance Control in SRF Cavities at FNAL

Download or read book Resonance Control in SRF Cavities at FNAL written by and published by . This book was released on 2011 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Lorentz force can dynamically detune pulsed Superconducting RF cavities. Considerable additional RF power can be required to maintain the accelerating gradient if no effort is made to compensate for this detuning. Compensation systems using piezo actuators have been used successfully at DESY and elsewhere to control Lorentz Force Detuning (LFD). Recently, Fermilab has developed an adaptive compensation system for cavities in the Horizontal Test Stand, in the SRF Accelerator Test Facility, and for the proposed Project X.