EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book ETUDE DU GONFLEMENT ET DE LA FLOCULATION DE GELS DE POLYELECTROLYTES

Download or read book ETUDE DU GONFLEMENT ET DE LA FLOCULATION DE GELS DE POLYELECTROLYTES written by Valérie Legrand and published by . This book was released on 1997 with total page 265 pages. Available in PDF, EPUB and Kindle. Book excerpt: LA DESHYDRATATION DES BOUES URBAINES FUT INVESTIEE AU TRAVERS DU GONFLEMENT/DEGONFLEMENT DE GELS POLYELECTROLYTES QUI SIMULE LE COMPORTEMENT PHYSICOCHIMIQUE DES BOUES TRAITEES PAR DES AGENTS DE CONDITIONNEMENT. LES RESULTATS OBTENUS AVEC LE RESEAU DE POLYMERE CONDITIONNE AVEC DES REACTIFS COMPLEXANTS MONTRENT L'INTERVENTION DE DEUX PHENOMENES : LA FLOCULATION ET LE DEGONFLEMENT. LE DEGONFLEMENT APPARAIT AUTOUR DE LA STOECHIOMETRIE GLOBALE DES CHARGES. DANS LE CAS DE LA FLOCULATION, LA BALANCE DES CHARGES ENTRE LES ESPECES CATIONIQUES ET ANIONIQUES A L'APPARITION DE LA FLOCULATION DEPEND DES CARACTERISTIQUES STRUCTURALES DES PRODUITS ANTAGONISTES TELLES QUE LA DENSITE DE CHARGES DU RESEAU ET LA DENSITE DE CHARGES DU RESEAU ET LA DENSITE DE CHARGE ET LE POIDS MOLECULAIRE DU REACTIF CATIONIQUE. LA FLOCULATION A ETE DEMONTREE COMME ETANT CONTROLEE PAR LA NEUTRALISATION DE LA CHARGE DE SURFACE. POUR COMPARAISON AVEC LES GELS, UNE SERIE D'EXPERIENCE A ETE REALISEE SUR LES BOUES D'ORIGINE URBAINE PROVENANT DE DIFFERENTS ETAPES DU TRAITEMENT DES EAUX USEES. LES BOUES ONT ETE DESTABILISEES PAR DES CONDITIONNEMENTS CATIONIQUES EN ESSAIS EN LABORATOIRE ET LA DOSE OPTIMALE DE FLOCULANT CORRELEE A LA DENSITE DE CHARGE DES BOUES QUI A ETE EVALUEE PAR POTENTIOMETRIE. LA FORCE IONIQUE DETERMINEE DANS LES BOUES DONNE LIEU A UNE REDUCTION DES INTERACTIONS ENTRE LE REACTIF CATIONIQUE ET LES PARTICULES ET DONC A UNE LIMITATION DES PERFORMANCES DE DESHYDRATATION. CETTE ETUDE MENEE SUR LES BOUES A CONDUIT A LA VALIDATION DU GEL MODELE ET A SON AJUSTEMENT EN AJOUTANT LA COMPOSANTE HYDROPHOBE. CES NOUVEAUX GELS MODELES TRAITES PAR DES POLYMERES CATIONIQUES ONT MIS EN EVIDENCE LE ROLE PRIMORDIAL DES INTERACTIONS HYDROPHOBES DANS LES MECANISMES DE FLOCULATION. CE SONT LES PROPRIETES HYDROPHILES-HYDROPHOBES DU POLYMERE QUI REGISSENT L'AGREGATION. CONTRAIREMENT AUX EFFETS ELECTROSTATIQUES, LES INTERACTIONS SONT RENFORCEES EN PRESENCE DE SEL. DES RESULTATS SIMILAIRES SONT OBSERVES DANS LES BOUES.

Book   tude de l efficacit   de chitosane comme conditionneur des boues biologiques

Download or read book tude de l efficacit de chitosane comme conditionneur des boues biologiques written by Chabha Belabid and published by . This book was released on 2001 with total page 158 pages. Available in PDF, EPUB and Kindle. Book excerpt: La capacité des équipements mécaniques est limitée par la nature complexe de la matrice de la boue. Il est connu que la boue a tendance à se lier avec l'eau et refuse de la libérer durant la déshydratation. L'étape de conditionnement est obligatoire pour une déshydratation efficace des boues. Les polymères synthétiques sont les plus communément utilisés comme conditionneurs. Malgré le rôle important qu'ils peuvent jouer, leur utilisation à long terme peut avoir un effet nuisible sur la santé humaine. Cette recherche étudie la faisabilité de l'utilisation du chitosane, polymère cationique naturel, dans le traitement des boues d'épuration de la station de Magog. L'utilisation de ce biopolymère obtenu, principalement, à partir des carapaces des crustacés serait d'un grand intérêt. Il permettrait d'éviter les risques sur la santé humaine et sur l'environnement. L'inexistence de méthodes disponibles de floculation au laboratoire a rendu indispensable la conception d'un floculateur et la mise au point d'une méthode de floculation. Pour mieux évaluer la capacité du biopolymère à conditionner les boues d'épuration, le Jeschem PAM C-3551, polymère synthétique fortement cationique, est utilisé au laboratoire en parallèle que le chitosane. Les résultats de floculation obtenus avec ces deux polymères étaient intéressants. Les flocs devenaient plus gros au fur et à mesure qu'on augmentait la dose du conditionneur. Le test de la résistance spécifique à la filtration est celui qui simule la déshydratation des boues avec des appareils conduisant à la formation d'un gâteau. Ce test est utilisé au laboratoire dans le but d'évaluer quantitativement l'efficacité du chitosane et déterminer le potentiel de déshydratation de la boue de la station d'épuration de Magog. La valeur de la résistance spécifique à la filtration ne peut pas être assignée si les données de filtration d'une boue ne suivent pas le modèle standard (présentant une partie linéaire caractérisant l'étape de la filtration et une partie asymptotique correspondant à la phase de l'assèchement). Les boues de la station d'épuration de Magog ont donné un cas où le tracé des données de filtration ne ressemblait pas à l'allure standard. Ce tracé a montré l'existence de deux parties linéaires avec des pentes différentes correspondant à des vitesses de filtration différentes. Les résultats de filtration obtenus ont montré que le chitosane est moins efficace que le Jeschem PAM C-3551. Néanmoins, il demeure intéressant puisque les valeurs de la résistance spécifique à la filtration obtenues (0.92 et 0.32 Tm/kg) avec les dosages optimums, suivant la date de prélèvement des boues, sont inférieures à la valeur (1.0 Tm/kg) suggérée comme valeur limite pour une filtration économique des boues. L'intérêt de son utilisation se situe plus sur sa biodégradabilté et l'abondance de la chitine d'où il est extrait.

Book Etude de la d  shydratation par respiration a  robie de boues de station d   puration

Download or read book Etude de la d shydratation par respiration a robie de boues de station d puration written by Valérie Boucher and published by . This book was released on 1996 with total page 424 pages. Available in PDF, EPUB and Kindle. Book excerpt: LE PROCEDE BIOSEC EST UN MOYEN BIOLOGIQUE DE DESHYDRATATION DE BOUE DE STATION D'EPURATION, IL UTILISE LA CHALEUR PRODUITE AU COURS DE LA FERMENTATION AEROBIE CONTROLEE DU MELANGE DE BOUE ET DE COPRODUITS LIGNOCELLULOSIQUES RECYCLABLES. LE CRIBLAGE DU MELANGE TRAITE PERMET D'OBTENIR UNE FRACTION FINE CONSTITUEE DE 85 A 90% DE BOUE TRANSFORMEE, LE RESTE ETANT DES COPRODUITS. CEPENDANT SON HUMIDITE VARIE EN FONCTION DES SAISONS ET DE LA TENEUR EN EAU DU PRODUIT INITIAL. UNE IMPORTANTE QUANTITE D'AZOTE EST PERDUE AU COURS DU TRAITEMENT (30 A 35% DE L'AZOTE INITIAL) PROVOQUANT UNE BAISSE DE LA VALEUR AGRONOMIQUE DU PRODUIT. POUR QUE LE PRODUIT FINAL SOIT STABLE SON HUMIDITE DOIT ETRE INFERIEURE OU EGALE A 35%. CETTE CARACTERISTIQUE EST OBTENUE SI LA BOUE A UNE HUMIDITE INFERIEURE A 81%. SI CELLE-CI EST SUPERIEURE (85 A 87%) L'APPORT DE 10 M#3 DE FRACTION FINE OBTENUE ANTERIEUREMENT PERMET D'OBTENIR 36% D'HUMIDITE EN ETE ET 45% EN HIVER, SOIT UNE AMELIORATION DE 6 A 11%. AU COURS DU PROCEDE BIOSEC, 2/3 DE L'ENERGIE PROVIENNENT DE LA DEGRADATION DES COPRODUITS ET 85% SONT UTILISES POUR DESHYDRATER LA BOUE. IL EST DONC EXCLU DE REMPLACER LES COPRODUITS LIGNOCELLULOSIQUES PAR DES MATERIAUX STRUCTURANTS INERTES. UNE IMPORTANTE PERTE EN AZOTE AU COURS DU PROCEDE S'EFFECTUE SOUS LA FORME D'AMMONIAC ENTRAINE PAR L'AIR EXTRAIT. L'APPORT D'UN AGENT ACIDIFIANT DIMINUERA CETTE PERTE. EN LABORATOIRE, DANS UN REACTEUR PILOTE, L'APPORT DE FEC1#3 DANS UN MELANGE DE BOUE DE STATION D'EPURATION ET DE COPRODUITS PROVOQUE UNE DIMINUTION DES PERTES EN AZOTE (FACTEUR 2,3 PAR RAPPORT AU TEMOIN). L'APPORT DE H#3 PO#4 DANS UN MELANGE DE BOUE RICHE EN PHOSPHATES DE CALCIUM SUPPRIME CETTE PERTE

Book Optimisation d une station d   puration

Download or read book Optimisation d une station d puration written by Chafiq Tkiouat and published by Omniscriptum. This book was released on 2014-02-28 with total page 104 pages. Available in PDF, EPUB and Kindle. Book excerpt: Cet ouvrage consiste en une optimisation du traitement des effluents, issus du processus de production de papier et rejetés dans le milieu naturel, afin de: réduire la charge polluante de ces rejets liquides par le biais d'un traitement physico-chimique puis biologique anaérobie ET réduire l'impact sur le milieu récepteur. Cette optimisation vise principalement la diminution de la quantité des réactifs injectés au niveau de chaque étape du traitement tout en gardant un rendement raisonnable au niveau de chaque étape. Cependant, on peut faire face à une augmentation de l'un des réactifs qui vise à situer les caractéristiques de sortie des effluents suivant les normes imposées.

Book Optimisation de la digestion ana  robie en deux   tapes des boues de station d   puration

Download or read book Optimisation de la digestion ana robie en deux tapes des boues de station d puration written by Chantal Perot and published by . This book was released on 1989 with total page 32 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book OPTIMISATION DE LA DIGESTION ANAEROBIE EN DEUX ETAPES DES BOUES DE STATIONS D EPURATION

Download or read book OPTIMISATION DE LA DIGESTION ANAEROBIE EN DEUX ETAPES DES BOUES DE STATIONS D EPURATION written by Chantal Pérot and published by . This book was released on 1989 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: ETUDE DE L'ETAPE LIMITANTE DE LA DIGESTION ANAEROBIE, CONSTITUEE PAR L'HYDROLYSE DE LA MATIERE ORGANIQUE ET OPTIMISATION DE CE PROCESSUS DANS LE CAS DES BOUES DE STATIONS D'EPURATION. LES CONDITIONS OPTIMALES POUR LA FLORE BACTERIENNE ASSURANT LES REACTIONS D'HYDROLYSE DE LA MATIERE ORGANIQUE DES BOUES ONT ETE DETERMINEES

Book Contribution    l optimisation d une unit   de deshydratation des boues r  siduaires urbaines

Download or read book Contribution l optimisation d une unit de deshydratation des boues r siduaires urbaines written by Marie-Laure Varescon and published by . This book was released on 1983 with total page 368 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Combinaison innovante de traitements   lectriques et physico chimiques pour am  liorer la d  shydratation m  canique de suspensions et boues d origines industrielles et urbaines

Download or read book Combinaison innovante de traitements lectriques et physico chimiques pour am liorer la d shydratation m canique de suspensions et boues d origines industrielles et urbaines written by and published by . This book was released on 2012 with total page 205 pages. Available in PDF, EPUB and Kindle. Book excerpt: Pressurized electro-osmotic dewatering (PEOD) of three sewage sludges and electrofiltration of waste drilling mud were studied with a laboratory chamber simulating closely an industrial filter-press. This work focuses on the influence of conditioning on the electro-dewatering, the comparison between different cell configurations and the process parameters optimization. The influence of pH, salt and polyelectrolytes on the electro-osmotic dewatering of agroindustrial sludge was studied. It was shown the strong impact of the electrolyte concentration on the process and notably that a high salt concentration is detrimental to the electrodewatering. The electrolytic hydroxide and hydronium ions formed at the electrodes change the course of the electro-dewatering. The addition of polymeric coagulants or flocculants has not significant influence on the PEOD of the sludge for the concentrations usually employed in sewage plants. A laboratory parametric study was also carried out in order to optimize the electro-osmotic dewatering. Various cell configurations (with one or two drainage sides, electrode material, initial cake thickness, and electrode/filter cloth position) were compared. The following process parameters were also studied: mechanical pressure, power supply, electrical mode, and timing of current application. The electrofiltration of waste drilling mud at 40 A/m2 accelerated by 4.0-4.6 times the filtration rate without electric field with 0.05-0.13 kWh/kg supplementary removed water. The use of a laboratory cell able to remove electrolysis products generated at the electrodes allows maintaining a constant pH in the filter cake during the electrofiltration.

Book Contribution    l   tude des ph  nom  nes de floculation

Download or read book Contribution l tude des ph nom nes de floculation written by François Colin and published by . This book was released on 1966 with total page 137 pages. Available in PDF, EPUB and Kindle. Book excerpt: Quelle que soit leur origine, il est actuellement nécessaire d'effectuer un traitement des eaux résiduaires contenant des matières solides en suspension afin d'éviter la pollution du milieu récepteur. [...]Une première partie de notre travail, constituée par l'étude des propriétés physiques et chimiques des boues étudiées, nous a permis de constater que ces boues contenaient une importante fraction de particules très fines, se déposant très lentement et possédant des propriétés voisines de celles de l'état colloïdal. Cette constatation nous a conduits à étudier les phénomènes de floculation de ces boues, qui permettent de détruire l'état colloïdal. Pour cela, nous avons étudié plus particulièrement les propriétés électriques des particules en suspension, et l'action des floculants sur ces propriétés et sur la stabilité des suspensions ; nous nous sommes limités aux polymères et polyélectrolytes organiques. Ces produits, relativement nouveaux et encore peu employés dans le traitement des boues résiduaires, se révèlent beaucoup plus efficaces que les floculants minéraux classiques, tout en présentant l'avantage de ne pas modifier les propriétés physico-chimiques du liquide de suspension (pH, teneur en sels diffus...). A notre connaissance, il n'y a pas encore eu d'étude systématique entreprise dans ce domaine ; seule l'action des floculants minéraux a été largement étudiée, surtout en ce qui concerne la floculation des argiles, problème important de l'alimentation en eau potable. La troisième partie de notre travail est consacrée à l'application de ces traitements de floculation à la déshydratation des boues résiduaires étudiées. Nous avons cherché à déterminer dans quelle mesure des traitements préliminaires de floculation étaient susceptibles d'améliorer les procédés classiques de déshydratation des boues : décantation, centrifugation, filtration sous vide et sous pression. Lorsque cela s'est révélé nécessaire, dans le cas de la centrifugation, nous avons réalisé cette étude pratique en utilisant une installation pilote comprenant une centrifugeuse de type semi-industriel. L'ensemble des résultats ainsi obtenus nous a permis de déterminer pour chaque type de boue étudiée le traitement qui nous paraissait techniquement le plus intéressant.

Book Optimisation de la d  shydratation et du conditionnement de boues provenant de traitements primaires et secondaires d effluents de papeti  res

Download or read book Optimisation de la d shydratation et du conditionnement de boues provenant de traitements primaires et secondaires d effluents de papeti res written by Martine Proulx and published by . This book was released on 1998 with total page 92 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Hydrolyse de boues primaires de station d   puration par une pr  paration cellulolytique industrielle  SP 348

Download or read book Hydrolyse de boues primaires de station d puration par une pr paration cellulolytique industrielle SP 348 written by Sabine Cugnart and published by . This book was released on 1994 with total page 125 pages. Available in PDF, EPUB and Kindle. Book excerpt: Actuellement, le traitement le plus intéressant pour stabiliser des boues de station d'épuration est la digestion anaérobie en deux étapes. La première phase, l'hydrolyse, est reconnue comme étant une étape limitante des processus de digestion anaérobie. Un des composants des boues, la cellulose, est un facteur limitant de la digestion anaérobie : sa dégradation nécessite l'intervention de plusieurs enzymes. L'hydrolyse de boues primaires, riches en cellulose, par une préparation cellulolytique industrielle, a fait l'objet de notre étude. La préparation enzymatique choisie est une préparation commerciale encore mal définie. Nous avons donc déterminé les conditions optimales de température et de pH de cette préparation enzymatique (50°C et pH6) et mis au point les méthodes de dosages des activités cellulolytiques afin de pouvoir la caractériser. Les études d'hydrolyse ont été réalisées à partir de boues primaires sous les conditions optimales de pH et de température de la préparation enzymatique. Le maximum de conversion de la fraction glucidique des boues primaires est obtenu après 24 heures d'hydrolyse, avec 3% (v/v) de préparation enzymatique. Sous ces conditions, nous avons obtenu 20% d'élimination des matières volatiles et une conversion de la fraction glucidique de 70%. La stabilité des activités cellulolytiques a été étudiée au cours de l'hydrolyse de boues primaires et a révélé, au temps initial, l'adsorption de l'activité endo-1,4-b-glucanase sur la partie insoluble des boues primaires d'une part, et une adsorption en continu des activités enzymatiques sur les particules de boues d'autre part. Afin de diminuer la quantité de préparation enzymatique utilisée, nous avons réalisé une hydrolyse de boues primaires fraiche en bioréacteur à membrane. Ce procédé a permis d'atteindre jusqu'a 42% de dégradation des matières volatiles en 24 heures.

Book Traitement des eaux pluviales par coagulation floculation

Download or read book Traitement des eaux pluviales par coagulation floculation written by Antoine Elsamrani and published by . This book was released on 2005 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Les objectifs de la thése sont d'optimiser le traitement de coagulation-floculation des eaux pluviales et d'identifier les principales phases porteuses des éléments traces dans les boues du traitement. L'identification des phases porteuses et la quantification de leur abondance ont été réalisées en utilisant la microscopie électronique à balayage et à transmission couplées à la spectroscopie d'énergie dispersive des rayons X. L'extraction parallèle des métaux lourds par ajout des réactifs appropriés a été utilisée pour une quantification de ceux-ci au sein de chaque fraction physico-chimique. On montre que les métaux lourds s'accumulent principalement au sein de phases sulfures dans les dépôts des réseaux unitaires et que celles-ci sont remise en suspension en temps pluvieux. Des signatures du lessivage des sols, des surfaces urbaines, et des dépôts des réseaux unitaires ont été mises en évidence. L'optimisation du traitement de coagulation-floculation des eaux pluviales a été abordée en reliant la concentration optimale en coagulant aux paramètres physicochimiques de l'effluent, tout en s'assurant de l'adéquation d'un tel traitement pour l'élimination des métaux lourds. La concentration optimale en coagulant peut être ajustée rapidement en fonction de la conductivité des effluents, celle-ci étant correlée linairement avec la concentration optimale. On montre également que la nature des espèces coagulantes est fortement influencée par les réactions entre les espèces hydrolysées du fer et les anions complexants dans les suspensions.

Book Floculation et filtration compression des boues biologiques

Download or read book Floculation et filtration compression des boues biologiques written by Béchir Ben Rejeb and published by . This book was released on 1988 with total page 160 pages. Available in PDF, EPUB and Kindle. Book excerpt: Étude de la floculation par des polymères cationiques des boues biologiques issues du traitement des eaux résiduaires. Mise en évidence du lien entre l'efficacité des polymères et leurs propriétés physiques (masse molaire et ionicité). Étude de la compressibilité des boues ainsi que sa variation en fonction du débit de filtration

Book R  alisation et mise au point d un test de lixiviation sous pression

Download or read book R alisation et mise au point d un test de lixiviation sous pression written by Mohamed Abdelghafour and published by . This book was released on 199? with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: UN DO-LIXIVIMETRE DE GRANDE TAILLE (F=250 MM) PERMETTANT DE MAITRISER LES GRADIENTS DE PRESSION MECANIQUE ET HYDRAULIQUE (SIMULATION DU COMPORTEMENT EN DECHARGE) A ETE CONSTRUIT, MIS AU POINT ET TESTE. UNE NOUVELLE PROCEDURE DE TEST SOUS PRESSION A ETE MISE AU POINT SUR UNE BOUE DE STATION D'EPURATION INDUSTRIELLE MALAXEE AVEC DE L'ARGILE ET/OU DE LA CHAUX OU DU GYPSE. CE TEST PRESENTE LA POSSIBILITE DE PERMETTRE LE CALCUL DU VOLUME DE SOLVANT (ET DONC DU TEMPS) NECESSAIRE A L'EXTRACTION DE 50% DES SUBSTANCES SOLUBLES DANS TOUS TYPES DE DECHETS

Book Analyse et optimisation de plusieurs proc  d  s d   limination de la mati  re organique naturelle dissoute en vue du traitement d eau potable

Download or read book Analyse et optimisation de plusieurs proc d s d limination de la mati re organique naturelle dissoute en vue du traitement d eau potable written by Ronan Treguer and published by . This book was released on 2013 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: La matière organique naturelle (MON) est devenue aujourd’hui un critère primordial de la qualité des eaux potables. Le premier objectif de ces travaux a été d’évaluer les performances de matériaux particulaires vis-à-vis de l’élimination de la MON après clarification, puis l’action de polymères cationiques, associés ou non à un coagulant classique, a été investiguée ; l’association des deux types de réactifs a ensuite été réalisée. Le charbon actif (CA) ayant confirmé son potentiel d’élimination de la MON, et l’amélioration de la coagulation – floculation ayant montré des limites, les travaux se sont tournés vers l’utilisation de CA. Après comparaison des performances de plusieurs CA commerciaux vis-à-vis de la MON dissoute, les travaux ont porté sur le couplage d’une suspension de CA d’âge élevé avec une séparation par ultrafiltration. Différentes techniques analytiques ont été utilisées : analyses de COD, de CODB, d’UV, utilisation de chromatographie d’exclusion stérique.