EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Nondestructive Assay Instrument for Measurement of Plutonium in Solutions

Download or read book Nondestructive Assay Instrument for Measurement of Plutonium in Solutions written by and published by . This book was released on 1979 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: A nondestructive assay (NDA) instrument that measures the 239Pu content in solutions, using a passive gamma-ray spectroscopy technique, has been developed and installed in the LASL Plutonium Processing Facility. A detailed evaluation of this instrument has been performed. The results show that the instrument can routinely determine 239Pu concentrations of 1 to 500 g/l with accuracies of 1 to 5% and assay times of 1 to 2 x 103 s.

Book In line Measurement of Plutonium and Americium in Mixed Solutions

Download or read book In line Measurement of Plutonium and Americium in Mixed Solutions written by and published by . This book was released on 1981 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: A solution assay instrument (SAI) has been developed at the Los Alamos National Laboratory and installed in the plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument is designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and Am/Pu ratios. For a 25-mL sample, the assay precision is 1%, both for plutonium and for americium having concentrations5 g/L within a 2000-s count time.

Book Integrated Nondestructive Assay Solutions for Plutonium Measurement Problems of the 21st Century

Download or read book Integrated Nondestructive Assay Solutions for Plutonium Measurement Problems of the 21st Century written by and published by . This book was released on 1997 with total page 25 pages. Available in PDF, EPUB and Kindle. Book excerpt: The authors describe automated and integrated nondestructive assay (NDA) systems configured to measure many of the materials that will be found in the Department of Energy complex in the dismantlement, disposition, residue stabilization, immobilization, and mixed oxide fuel programs. These systems are typified by the Advanced Recovery and Integrated Extraction System NDA system which is under construction at Los Alamos National Laboratory to measure the outputs of a weapon component dismantlement system.

Book Passive Nondestructive Assay of Nuclear Materials

Download or read book Passive Nondestructive Assay of Nuclear Materials written by Doug Reilly and published by . This book was released on 1991 with total page 700 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book In plant Measurements of Gamma ray Transmissions for Precise K edge and Passive Assay of Plutonium Concentration and Isotopic Fractions in Product Solutions  Final Report on TASTEX Task G

Download or read book In plant Measurements of Gamma ray Transmissions for Precise K edge and Passive Assay of Plutonium Concentration and Isotopic Fractions in Product Solutions Final Report on TASTEX Task G written by and published by . This book was released on 1982 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: An instrument based upon high-resolution gamma-ray measurements has been tested for more than 1 year at the Tokai Reprocessing Facility for determination of plutonium concentration by K-edge absorption densitometry and for determination of plutonium isotopic fractions by transmission-corrected passive gamma-ray spectrometry. The nondestructive assay instrument was designed and built at Los Alamos National Laboratory for the Tokai Advanced Safeguards Technology Exercise (TASTEX). It was used at Tokai for the timely assay of more than 100 product solution samples during the TASTEX evaluations. The results were compared to reference values obtained by conventional destructive analysis of these samples. The precision and accuracy of plutonium concentrations measured by the K-edge technique are shown to be within 0.6% (1delta) in these applications. The precisions and accuracies of the isotopic fractions determined by these passive gamma-ray methods are shown to be within 0.4% for 239Pu, 1% for 24°Pu and 241Pu, and 10% for 242Pu.

Book Energy Research Abstracts

Download or read book Energy Research Abstracts written by and published by . This book was released on 1992 with total page 806 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Integrated Nondestructive Assay System for a New Plutonium Scrap Recovery Facility

Download or read book Integrated Nondestructive Assay System for a New Plutonium Scrap Recovery Facility written by and published by . This book was released on 1985 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: A consortium of laboratories is collaborating with the Savannah River Plant to develop an integrated system of state-of-the-art nondestructive assay (NDA) instrumentation to provide nuclear materials accounting and process control information for a new plutonium scrap recovery facility. Individual microcomputer-based instruments report assay results to an Instrument Control Computer (ICC). The ICC, in turn, is part of a larger computer network that includes computers that perform process control and nuclear materials accounting functions. Integrated system design considerations, integral testing, and individual instrument measurement functions are discussed. 3 refs., 3 figs., 1 tab.

Book Field Nondestructive Assay Measurements as Applied to Process Inventories

Download or read book Field Nondestructive Assay Measurements as Applied to Process Inventories written by and published by . This book was released on 1979 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: An annual process equipment holdup inventory measurement program for a plutonium processing plant was instituted by Rockwell Hanford Operations (Rockwell) at Richland, Washington. The inventories, performed in 1977 and 1978, were designed to improve plutonium accountability and control. The inventory method used field nondestructive assay (NDA) measurement techniques with portable electronics and sodium iodide detectors. Access to and movement of plutonium in work areas was curtailed during the inventory process using administrative controls. Comparison of the two annual inventories showed good reproducibility of results within the calculated error ranges. For items where no plutonium movement occurred and which contained greater than 20 grams plutonium, the average measurement difference between the two inventories was 22%. The procedures and equipment used and the operational experience from the inventories are described.

Book Development of a Plutonium Solution assay Instrument with Isotopic Capability

Download or read book Development of a Plutonium Solution assay Instrument with Isotopic Capability written by and published by . This book was released on 1992 with total page 6 pages. Available in PDF, EPUB and Kindle. Book excerpt: A new generation of solution-assay instrument has been developed to satisfy all the assay requirements of an aqueous plutonium-recovery operation. The assay is based on a transmission-corrected passive assay technique. We have demonstrated that the system can cover a concentration range of 0.5--300 g/l with simultaneous isotopic determination. The system can be used to assay input and eluate streams of the recovery operation. The system can be modified to measure low-concentration effluent solutions from the recovery operation covering 0.01--40 g/l. The same system has also been modified to assay plutonium solutions enriched in 242Pu. 6 refs.

Book NBS Special Publication

Download or read book NBS Special Publication written by and published by . This book was released on 1968 with total page 684 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Nuclear Science Abstracts

Download or read book Nuclear Science Abstracts written by and published by . This book was released on 1975-02 with total page 850 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Nondestructive Assay Methods for Solids Containing Plutonium

Download or read book Nondestructive Assay Methods for Solids Containing Plutonium written by and published by . This book was released on 1984 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Specific nondestructive assay (NDA) methods, e.g. calorimetry, coincidence neutron counting, singles neutron counting, and gamma ray spectrometry, were studied to provide the Savannah River Plant with an NDA method to measure the plutonium content of solid scrap (slag and crucible) generated in the JB-Line plutonium metal production process. Results indicate that calorimetry can be used to measure the plutonium content to within about 3% in 4 to 6 hours by using computerized equilibrium sample power predictive models. Calorimetry results confirm that a bias exists in the present indirect measurement method used to estimate the plutonium content of slag and crucible. Singles neutron counting of slag and crucible can measure plutonium to only +-30%, but coincidence neutron counting methods improve measurement precision to better than +-10% in less than ten minutes. Only four portions of a single slag and crucible sample were assayed, and further study is recommended.

Book Measurement Technology for Safeguards and Materials Control

Download or read book Measurement Technology for Safeguards and Materials Control written by Thomas R. Canada and published by . This book was released on 1980 with total page 776 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Measurement technology for safeguards and materials control

Download or read book Measurement technology for safeguards and materials control written by American Nuclear Society and published by . This book was released on 1980 with total page 776 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Instrument for Measurement of Pu Concentration and Isotopics of Product Solutions at Tokai mura

Download or read book Instrument for Measurement of Pu Concentration and Isotopics of Product Solutions at Tokai mura written by and published by . This book was released on 1980 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Rapid analysis of product solutions for plutonium concentrations and isotopic distributions is accomplished by a new instrument currently installed at the reprocessing plant in Tokai-mura, Japan. Better than half-percent measurements of the Pu concentration are obtained by K-edge densitometry for concentrations approx. 250 g Pu/l in short count times. Isotopic fractions are determined with an accuracy of one percent or better in an additional 30-minute passive count.