EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book National Dam Inspection Program  Refuse Settling Basin  NDI Number PA 00908  PennDER Number 63 78   Ohio River Basin  Sawmill Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Refuse Settling Basin NDI Number PA 00908 PennDER Number 63 78 Ohio River Basin Sawmill Creek Washington County Pennsylvania Phase I Inspection Report written by ACKENHEIL AND ASSOCIATES INC PITTSBURGH PA. and published by . This book was released on 1980 with total page 103 pages. Available in PDF, EPUB and Kindle. Book excerpt: The general condition of the Refuse Settling Basin is considered to be fair. This assessment is based on visual observations that indicate a possible inadequate margin of safety against slope failure of a high ground water level exists in Embankment A. The condition is not considered to represent an immediate threat to the structure because of the relatively low impoundment pool elevation. It should, however, be evaluated. If a high ground water does not exist in Embankment A, the facility can be considered to be in good condition. The structure is classified as an 'intermediate' size, 'high' hazard dam. Corps of Engineers guidelines recommend the Probable Maximum Flood (PMF) as the Spillway Design Flood for an 'intermediate' size, 'high' hazard dam. The visual inspection indicated several minor deficiencies in addition to the possible high ground water condition. The deficiencies can be corrected or improved through implementation of the following recommended evaluation, remedial, monitoring and/or maintenance efforts.

Book Technical Abstract Bulletin

Download or read book Technical Abstract Bulletin written by and published by . This book was released on 1980 with total page 206 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book National Dam Inspection Program  Montour Number 4 Refuse Bank  NDI Number PA 00865  PENN DER Number 63 92   Ohio River Basin  Tributary to Chartiers Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Montour Number 4 Refuse Bank NDI Number PA 00865 PENN DER Number 63 92 Ohio River Basin Tributary to Chartiers Creek Washington County Pennsylvania Phase I Inspection Report written by and published by . This book was released on 1981 with total page 74 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a review of available information, visual observations of conditions as they existed on the date of the field inspection, and supporting engineering calculations, the general condition of the Montour No. 4 Refuse Bank is considered to be fair. This assessment is based primarily on visual observations of the embankment. The structure is classified as a large size, significant hazard dam. Corps of Engineers guidelines recommend the Probable Maximum Flood (PMF) as the Spillway Design Flood for a large size significant hazard dam. Montour No. 4 Refuse Bank's Spillway Design Flood is the Probable Maximum Flood. Reservoir capacity is 'adequate' because the non-overtopping flood inflow was found, by using the HEC-1 computer program, to be in excess of 100 percent of the PMF.

Book National Dam Inspection Program  Raw Water Pond  NDI Number PA 01137  PennDER Number 61 90  Ohio River Basin  Sawmill Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Raw Water Pond NDI Number PA 01137 PennDER Number 61 90 Ohio River Basin Sawmill Creek Washington County Pennsylvania Phase I Inspection Report written by Samuel G. Mazzella and published by . This book was released on 1980 with total page 82 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Raw Water Pond was designed and constructed as an earthfill structure with clay core and cutoff along the centerline. The embankment is 1190 feet long, with a toe to crest height of 25.2 feet and a crest width of 25 feet. The Raw Water Pond outlet works is a 14 inch diameter steel pipe with an intake at the bottom of the Pond. The outlet works maintains the operating pool approximately 1.5 feet below the invert of the principal (and emergency) spillway. A gate valve and flow monitoring weir box are located downstream of the embankment. Outlet works flows are discharged to the Treated Water Pond below. Based on a review of available design information and visual observations of conditions as they existed on the date of the field inspection, the general condition of the Raw Water Pond is considered to be poor. This assessment is based primarily on visual observations that indicate a possible inadequate margin of safety against slope failure of the embankment. Spillway capacity is 'inadequate' because the non-overtopping flood discharge was found, by using the HEC-1 computer program, to be in 0.18 PMF.

Book National Dam Inspection Program  Mine Number 51   Pond 3  NDI Number PA 00863  PennDER Number 63 94  Ohio River Basin Tributary to Pigeon Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Mine Number 51 Pond 3 NDI Number PA 00863 PennDER Number 63 94 Ohio River Basin Tributary to Pigeon Creek Washington County Pennsylvania Phase I Inspection Report written by and published by . This book was released on 1981 with total page 73 pages. Available in PDF, EPUB and Kindle. Book excerpt: Mine No. 51 - Pond 3 is located at the headwaters of an unnamed tributary to Pigeon Creek in Somerset Township, Washington County, Pennsylvania. The pond is approximately 1/2 mile north of Ellsworth, Pennsylvania. Mine No. 51 - Pond 3 was constructed to serve as a holding and settling impoundment for fine coal refuse slurry from the Mine No. 51 Coal Preparation Plant. Based on the observed downstream conditions, Mine No. 51 - Pond 3 was assigned a high hazard potential rating.

Book Government Reports Announcements   Index

Download or read book Government Reports Announcements Index written by and published by . This book was released on 1981 with total page 1052 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book National Dam Inspection Program  Silt Pond A   NDI Number PA 00823 PENNDER Number 63 77  Ohio River Basin  Pigeon Creek  Washington County  Pennsylvania  United States Steel Corporation  Raw Materials Division  Phase I Inspection Report

Download or read book National Dam Inspection Program Silt Pond A NDI Number PA 00823 PENNDER Number 63 77 Ohio River Basin Pigeon Creek Washington County Pennsylvania United States Steel Corporation Raw Materials Division Phase I Inspection Report written by ACKENHEIL AND ASSOCIATES INC PITTSBURGH PA. and published by . This book was released on 1981 with total page 81 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a review of available design information and visual observations of conditions as they existed on the date of the field inspection, the general condition of Silt Pond A is considered to be good. This assessment is based primarily on visual observations of the embankment and appurtenances, and hydrologic/hydraulic analyses of reservoir/spillway capacity. The structure is classified as a 'small' size, 'high' hazard dam. Corps of Engineers guidelines recommend one-half to one times the Probable Maximum Flood (PMF) as the Spillway Design Flood for a 'small' size, 'high' hazard dam. Silt Pond A's Spillway Design Flood is the Probable Maximum Flood. Spillway capacity is 'adequate' because the non-overtopping flood discharge was found, by using the HEC-1 computer program, to be in excess of 100 percent of the PMF. The field inspection indicated three minor deficiencies which can be corrected or improved through implementation of the following recommended evaluation, remedial and/or maintenance efforts.

Book National Dam Inspection Program  Silt Pond B   NDI Number PA 00824 PENN DER Number 63 77  Ohio River Basin  Pigeon Creek  Washington County  Pennsylvania  United States Steel Corporation  Raw Materials Division  Phase I Inspection Report

Download or read book National Dam Inspection Program Silt Pond B NDI Number PA 00824 PENN DER Number 63 77 Ohio River Basin Pigeon Creek Washington County Pennsylvania United States Steel Corporation Raw Materials Division Phase I Inspection Report written by ACKENHEIL AND ASSOCIATES GEO SYSTEMS INC PITTSBURGH PA. and published by . This book was released on 1981 with total page 82 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a review of available design information and visual observations of conditions as they existed on the date of the field inspection, the general condition of Silt Pond B is considered to be good. This assessment is based primarily on visual observations of the embankment and appurtenances and hydrologic/hydraulic analyses of reservoir/spillway capacity. The structure is classified as an 'intermediate' size, 'high' hazard dam. Corps of Engineers guidelines recommend the Probable Maximum Flood (PMF) as the Spillway Design Flood for an 'intermediate' size, 'high' hazard dam. Silt Pond B's Spillway Flood is the Probable Maximum Flood. Spillway capacity is 'adequate' because the non-overtopping flood discharge was found, by using the HEC-1 computer program, to be in excess of 100 percent of the PMF. The field inspection indicated several minor deficiencies which can be corrected or improved through implementation of the following recommended evaluation, remedial and/or maintenance efforts.

Book Government Reports Annual Index

Download or read book Government Reports Annual Index written by and published by . This book was released on 1981 with total page 1192 pages. Available in PDF, EPUB and Kindle. Book excerpt: Sections 1-2. Keyword Index.--Section 3. Personal author index.--Section 4. Corporate author index.-- Section 5. Contract/grant number index, NTIS order/report number index 1-E.--Section 6. NTIS order/report number index F-Z.

Book National Dam Inspection Program  Neal Dam  NDI Number PA 00494  PennDER Number 63 68   Ohio River Basin  Branch of Chartiers Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Neal Dam NDI Number PA 00494 PennDER Number 63 68 Ohio River Basin Branch of Chartiers Creek Washington County Pennsylvania Phase I Inspection Report written by John A. Dziubek and published by . This book was released on 1980 with total page 78 pages. Available in PDF, EPUB and Kindle. Book excerpt: Neal Dam, owned and operated by Vernon C. Neal, is classified as a 'Small' size - 'significant' hazard dam. The dam was found to be in good overall condition at the time of inspection. Hydraulic/hydrologic evaluations, performed in accordance with procedures established by the Baltimore District, Corps of Engineers, for Phase I Inspection Reports, revealed that the spillway will pass the 100-year flood without overtopping the dam. A spillway design flood (SDF) in the range of the 100-year flood to the 1/2 Probable Maximum Flood (1/2 PMF) is required for Neal Dam. The 100-year flood was chosen because the dam is on the low side of the 'Small' size category. The spillway is therefore considered 'adequate.' Several minor items of remedial work should be performed by the owner as soon as practicable.

Book National Dam Inspection Program  Unnamed Tributary to Harmon Creek   NDI Number PA 01125   PennDER Number 63 84  SCS Number PA 480  Ohio River Basin  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Unnamed Tributary to Harmon Creek NDI Number PA 01125 PennDER Number 63 84 SCS Number PA 480 Ohio River Basin Washington County Pennsylvania Phase I Inspection Report written by John A. Dziubek and published by . This book was released on 1980 with total page 87 pages. Available in PDF, EPUB and Kindle. Book excerpt: PA 480 was designed by the U.S. Department of Agriculture, Soil Conservation Service (SCS) for floodwater detention. The total length of the dam is 555 feet, including the emergency spillway on the right abutement; the maximum height of the dam is 66 feet. The principal spillway is a drop-inlet structure consisting of a two-stage reinforced concrete riser connected to a 30 inch diameter reinforced concrete outlet pipe. The low-level inlet on the concrete riser is a 9 inch high by 15 inch wide orifice; this inlet maintains the normal pool level. There is 25.1 acre-feet of storage at normal pool level, all of which is reserved for a 50-year accumulation of sediment. Hydraulic/hydrologic evaluations, revealed that the spillway will pass the Probable Maximum Flood (PMF) without overtopping the dam. A spillway design flood (SDF) in the range of the 1/2 Probable Maximum Flood (1/2 PMF) to the PMF is required for PA 480. The 1/2 PMF was selected as the SDF. The spillway is therefore considered to be 'adequate'.

Book National Dam Inspection Program  PA 479 Dam  NDI ID Number PA 509  DER ID Number 63 71   Ohio River Basin  Harmon Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program PA 479 Dam NDI ID Number PA 509 DER ID Number 63 71 Ohio River Basin Harmon Creek Washington County Pennsylvania Phase I Inspection Report written by D'APPOLONIA CONSULTING ENGINEERS INC PITTSBURGH PA. and published by . This book was released on 1979 with total page 75 pages. Available in PDF, EPUB and Kindle. Book excerpt: The PA-479 dam is one of the 14 flood control projects in the Harmon Creek watershed. The dam consists of an earth embankment approximately 650 feet long with a maximum height of 63 feet from the downstream toe and a crest width of 14 feet. The flood discharge facilities for the dam consist of a drop inlet primary spillway located near the left abutment (looking downstream) and an emergency spillway, also located on the left abutment. Based on the evaluation of the conditions as they existed on the dates of inspection and as revealed by visual observations, the condition of PA-479 dam is assessed to be good. The spillway capacity is classified as adequate according to the recommended criteria.

Book National Dam Inspection Program  Trax Farm Dam  NDI Number PA 00131  PennDer Number 63 96  Ohio River Basin  Tributary to Peters Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Trax Farm Dam NDI Number PA 00131 PennDer Number 63 96 Ohio River Basin Tributary to Peters Creek Washington County Pennsylvania Phase I Inspection Report written by and published by . This book was released on 1981 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt: Trax Farm Dam is located across an unnamed tributary to Peters Creek in Peters Township, Washington County, Pennsylvania, approximately 2.5 miles northwest of Finleyville, Pennsulvania. Trax Farm Dam was constructed to provide a water supply for irrigation. Based upon the observed height of the dam and downstream floodplain conditions, Trax Farm Dam was assigned a 'high' hazard potential rating.

Book National Dam Inspection Program  PA 647 Dam  NDI ID Number PA 812  DER ID Number 63 76   Ohio River Basin  Robinson Fork  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program PA 647 Dam NDI ID Number PA 812 DER ID Number 63 76 Ohio River Basin Robinson Fork Washington County Pennsylvania Phase I Inspection Report written by D'APPOLONIA CONSULTING ENGINEERS INC PITTSBURGH PA. and published by . This book was released on 1979 with total page 80 pages. Available in PDF, EPUB and Kindle. Book excerpt: The PA-647 dam is one of the seven flood control structures in the Wheeling Creek watershed. The dam consists of an earth embankment approximately 500 feet long with a maximum height of 95 feet from the downstream toe and a crest width of 15 feet. The flood discharge facilities for the dam consist of a drop inlet type primary spillway located near the left abutment (looking downstream) and an emergency spillway on the right abutment. Based on the evaluation of the conditions as they existed on the dates of inspection and as revealed by visual observations, the condition of PA-647 dam is considered to be good. The spillway capacity is classified to be adequate according to the recommended criteria.

Book National Dam Inspection Program  Harmar Refuse Bank Dam  NDI Number PA  00835  PennDER Number 2 53   Ohio River Basin  Tributary to Guys Run  Allegheny County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Harmar Refuse Bank Dam NDI Number PA 00835 PennDER Number 2 53 Ohio River Basin Tributary to Guys Run Allegheny County Pennsylvania Phase I Inspection Report written by and published by . This book was released on 1981 with total page 82 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Harmar Refuse Bank is located on an unnamed tributary to Guy's Run in Harmar Township, Allegheny County, Pennsylvania, approximately one mile north of Harmarville, Pennsylvania. Harmar Refuse Bank was constructed as a disposal area for coarse and fine coal refuse from the Harmar Mine and Preparation Plant. Harmar Refuse Bank was assigned a 'high' hazard potential rating. This rating is based on the observed height and impounding capacity of the pond and the downstream floodplain conditions, which included numerous inhabited dwellings and Guy's Run Road. Failure of the Harmar Refuse Bank could result in significant disruption of commercial activities and loss of more than a few lives could result.

Book National Dam Inspection Program  PA 482 Dam  NDI I D  Number PA 469  DER I D  Number 63 72   Ohio River Basin  Tributary of Harmon Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program PA 482 Dam NDI I D Number PA 469 DER I D Number 63 72 Ohio River Basin Tributary of Harmon Creek Washington County Pennsylvania Phase I Inspection Report written by D'APPOLONIA CONSULTING ENGINEERS INC PITTSBURGH PA. and published by . This book was released on 1979 with total page 72 pages. Available in PDF, EPUB and Kindle. Book excerpt: The PA-482 dam is one of the 14 flood control projects in the Harmon Creek watershed. The dam consists of an earth embankment approximately 460 feet long with a maximum height of 38 feet from the downstream toe and a crest width of 14 feet. The flood discharge facilities for the dam consist of a drop inlet primary spillway located at the center of the embankment and an emergency spillway on the left abutment (looking downstream). The primary spillway structures consist of a two-stage reinforced concrete riser, a 24-inch-diameter reinforced concrete conduit, and a reinforced concrete impact basin at the downstream end of the outlet pipe. The emergency spillway is a 200-foot-wide trapezoidal earth channel excavated into the left abutment. The reservoir outlet for the dam consists of a 15-inch steel pipe extending from the upstream toe of the dam to the drop inlet structure. Flow through the reservoir outlet is controlled by a manually operated sluice gate lcoated in the drop inlet structure.

Book National Dam Inspection Program  Chambers Dam  NDI ID Number PA 1093  DER ID Number 63 21   Ohio River Basin  Bane Creek  Washington County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Chambers Dam NDI ID Number PA 1093 DER ID Number 63 21 Ohio River Basin Bane Creek Washington County Pennsylvania Phase I Inspection Report written by KIMBALL (L ROBERT) AND ASSOCIATES EBENSBURG PA. and published by . This book was released on 1981 with total page 73 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Chambers Dam appears to be in poor condition and poorly maintained. Erosion of the upstream slope has reduced the embankment crest to a width of 4 feet. Minor seepage was observed on the downstream slope of the dam, and a wet area was observed immediately beyond the toe of the dam. Brush and trees litter the downstream slope of the dam. No determination could be made as to the actual condition of the drainline culvert through the embankment. No determination could be made as to the condition or type of upstream closure on the culvert or whether the control is operable. The spillway located at the right abutment of the dam is in a deteriorating condition. Erosion exists along the right outside edge of the spillway wingwall. If the erosion is left unchecked, the potential for failure of the spillway and dam exists. The Chambers Dam is a high hazard-small size dam. The recommended Spillway Design Flood (SDF) for a dam of this size and classification is in the range of 1/2 PMF to PMF. Based on the downstream potential for loss of life and property damage, the spillway design flood has been selected as the PMF. The spillway and reservoir are capable of controlling less than 1% of the PMF without overtopping the embankment low spot.