Book National Dam Inspection Program  Pikes Creek Dam  NDS PA 00576 DER 40 18   Susquehanna River Basin  Pikes Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Pikes Creek Dam NDS PA 00576 DER 40 18 Susquehanna River Basin Pikes Creek Luzerne County Pennsylvania Phase I Inspection Report written by GANNETT FLEMING CORDDRY AND CARPENTER INC HARRISBURG PA. and published by . This book was released on 1978 with total page 97 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367, authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspection of dams throughout the United States. The purpose of the inspection is to determine if the dam constitutes a hazard to human life or property.

Book Technical Abstract Bulletin

Download or read book Technical Abstract Bulletin written by and published by . This book was released on 1979 with total page 1186 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book National Dam Inspection Program  Gardner Creek Dam  NDS PA 00575    DER 40 1   Pennsylvania Gas Water Company  Susquehanna River Basin  Gardner Creek  Luzerne County  Pennsylvania  Phase I  DER 40 1   Pennsylvania Gas Inspection Report

Download or read book National Dam Inspection Program Gardner Creek Dam NDS PA 00575 DER 40 1 Pennsylvania Gas Water Company Susquehanna River Basin Gardner Creek Luzerne County Pennsylvania Phase I DER 40 1 Pennsylvania Gas Inspection Report written by GANNETT FLEMING CORDDRY AND CARPENTER INC HARRISBURG PA. and published by . This book was released on 1978 with total page 97 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367, authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspection of dams throughout the United States. The purpose of the inspection is to determine if the dam constitutes a hazard to human life or property.

Book National Dam Inspection Program  Huntsville Dam  NDS PA 00553    DER 40 5   Pennyslvania Gas and Water Company  Susquehanna River Basin  Huntsville Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Huntsville Dam NDS PA 00553 DER 40 5 Pennyslvania Gas and Water Company Susquehanna River Basin Huntsville Creek Luzerne County Pennsylvania Phase I Inspection Report written by GANNETT FLEMING CORDDRY AND CARPENTER INC HARRISBURG PA. and published by . This book was released on 1978 with total page 87 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367, authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspection of dams throughout the United States. The purpose of the inspection is to determine if the dam constitutes a hazard to human life or property.

Book National Dam Inspection Program  Mill Creek Dam  NDS PA 00548 DER 40 2   Susquehanna River Basin  Mill Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Mill Creek Dam NDS PA 00548 DER 40 2 Susquehanna River Basin Mill Creek Luzerne County Pennsylvania Phase I Inspection Report written by GANNETT FLEMING CORDDRY AND CARPENTER INC HARRISBURG PA. and published by . This book was released on 1978 with total page 74 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on the visual inspection, available records, calculations and past operational performance, Mill Creek Dam is judged to be in good condition. However, the spillway (main and auxiliary) will not pass the Probable Maximum Flood (PMF) without overtopping the dam. Therefore, based on criteria established for these studies by the Department of the Army, Office of the Chief of Engineers (OCE), the spillway capacity is rated as inadequate. The spillway will pass one-half the PMF without overtopping the dam. Therefore, based on the OCE criteria established for these studies, the spillway capacity is not rated as seriously inadequate. The existing spillway can accommodate a flood with a peak inflow of 67 percent of the PMF peak flow. The spillway capacity is controlled by the elevation of a low area on the top of dam near the spillway. If the top of the dam were brought up to the design elevation, the spillway would accommodate a flood with a peak inflow of 118 percent of the PMF peak inflow. The spillway would then be rated as adequate. (Author).

Book National Dam Inspection Program  Frances Slocum Dam  NDS ID PA 00574  DER ID 40 218   Susquehanna River Basin  Abrahams Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Frances Slocum Dam NDS ID PA 00574 DER ID 40 218 Susquehanna River Basin Abrahams Creek Luzerne County Pennsylvania Phase I Inspection Report written by GANNETT FLEMING CORDDRY AND CARPENTER INC HARRISBURG PA. and published by . This book was released on 1978 with total page 81 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on the visual inspection, available records, calculations and past operational performance, Frances Slocum Dam is judged to be in good condition. The spillway will pass the Probable Maximum Flood (PMF) without overtopping the dam. Based on criteria established for these studies by the Department of the Army, Office of the Chief of Engineers (OCE), the spillway capacity is rated as adequate. The existing spillway can accommodate a flood with a peak inflow of 146 percent of the PMF flow. If the low areas of the top of the embankment were brought up to design grade, the spillway could accommodate a flood with a peak inflow of 154 percent of the PMF peak inflow.

Book National Dam Inspection Program  Lake Louise Dam  NDS ID Number PA 558  DER ID Number 40 134   Susquehanna River Basin  Suttons Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Lake Louise Dam NDS ID Number PA 558 DER ID Number 40 134 Susquehanna River Basin Suttons Creek Luzerne County Pennsylvania Phase I Inspection Report written by R. Jeffrey Kimball and published by . This book was released on 1980 with total page 100 pages. Available in PDF, EPUB and Kindle. Book excerpt: Lake Louise Dam appears to be in poor condition. Lake Louise Dam is a high hazard small size dam. The spillway design flood is in the range of 1/2 PMF to PMF. The spillway design flood was selected to be the PMF (probable maximum flood) based on downstream potential for loss of life and property damage. The spillway is capable of controlling approximately 45% of the PMF. The dam breach analysis indicated that a significant increase in the downstream potential for loss of life and property damage exists should the dam fail. Based on criteria established by the Corps of Engineers, the spillway is termed seriously inadequate. The spillway exit and entrance channels are in poor condition. The heavy vegetation creates the potential for water infiltration and made visual inspection of the embankment difficult. Lake Louise Dam is classified as an unsafe non-emergency dam.

Book National Dam Inspection Program  Brown Creek Dam  NDS ID Number PA 573  DER ID Number 40 208  Borough of Plymouth  Susquehanna River Basin  Brown Creek  Luzerne County  Phase I Inspection Report

Download or read book National Dam Inspection Program Brown Creek Dam NDS ID Number PA 573 DER ID Number 40 208 Borough of Plymouth Susquehanna River Basin Brown Creek Luzerne County Phase I Inspection Report written by KIMBALL (L ROBERT) AND ASSOCIATES EBENSBURG PA. and published by . This book was released on 1980 with total page 82 pages. Available in PDF, EPUB and Kindle. Book excerpt: The assessment of Brown Creek Dam is based upon visual observations made at the time of inspection, review of available records and data, hydraulic and hydrologic computations and past operational performance. The Brown Creek Dam appears to be in fair condition. The erosion on the crest and downstream embankment in the area of the principal spillway and along the wingwall of the emergency spillway crest should be repaired. Because the reservoir was dry (as is the normal condition) no determination as to potential wet zones or seepage areas could be made. Maintenance of the dam and operating facilities is considered fair. The Brown Creek Dam is a high hazard-small dam. The recommended spillway design flood (SDF) for this dam is the 1/2 PMF to PMF. Based on the potential for downstream loss of life, the spillway design flood has been selected as the PMF. The spillway and reservoir are capable of controlling approximately 80% of the PMF without overtopping the embankment (low spot). Based on criteria established by the Corps of Engineers, the spillway is termed inadequate.

Book National Dam Inspection Program  Lake of the Four Seasons Dam  NDS ID Number PA 568  DER ID Number 40 225  Susquehanna River Basin  Oley Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Lake of the Four Seasons Dam NDS ID Number PA 568 DER ID Number 40 225 Susquehanna River Basin Oley Creek Luzerne County Pennsylvania Phase I Inspection Report written by R. Jeffrey Kimball and published by . This book was released on 1980 with total page 103 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Lake of the Four Seasons Dam consists of two earthfill impounding structures. The main embankment (dam) is an earthfill dam, 1500 feet long and 29 feet high. At the left abutment of the main embankment (dam) are two spillways. One spillway consists of a concrete culvert type spillway, modified to function as an orifice. Immediately adjacent to the concrete structure at the left abutment is an open earth cut channel which serves as a temporary auxiliary spillway for the dam. The second impounding structure (dike) is located approximately 1/2 mile southwest of the main embankment. The dike is approximately 600 feet long, and 26 feet high. A permanent concrete ogee spillway is located approximately 500 feet southwest of the dike on the left abutment. The spillway and reservoir are capable of controlling approximately 54% of the PMF. Definitions used by the Corps of Engineers indicate that the spillway should be rated as inadequate. However, the temporary and permanent (as designed) auxiliary spillway has the potential for erosion of the exit channel and subsequent erosion of the toe of dam. It is possible that a failure of the dam could result at less than 1/2 PMF by erosion of the embankment toe.

Book National Dam Inspection Program  Shickshinny Lake Dam  NDS ID Number PA 572  DER ID Number 40 220   Susquehanna River Basin  Shickshinny Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Shickshinny Lake Dam NDS ID Number PA 572 DER ID Number 40 220 Susquehanna River Basin Shickshinny Creek Luzerne County Pennsylvania Phase I Inspection Report written by KIMBALL (L ROBERT) AND ASSOCIATES EBENSBURG PA. and published by . This book was released on 1980 with total page 77 pages. Available in PDF, EPUB and Kindle. Book excerpt: Shickshinny Lake Dam is an earthfill dam, 365 feet long and 33 feet high. The crest width of the dam is 17 feet. The upstream slope is 3H:1V and the downstream slope is 2.5H:1V. Both the upstream and downstream slopes are grass covered. Some riprap exists on the upstream slope. The principal spillway consists of a reinforced concrete riser and a 30 inch reinforced concrete pipe which passes under the dam. The top of the riser unit is provided with an anti-vortex device. A gate valve is provided on an inlet pipe just inside the riser unit. Based on our hydraulic and hydrologic analysis it was determined that the spillway and reservoir are capable of controlling approximately 52% of the PMF. Based on criteria established by the Corps of Engineers, the spillway is termed inadequate. No major deficiencies were observed during the inspection. Seepage was noted at the left abutment contact and did not appear to be excessive. Erosion was observed at the outlet structure for the spillway and drainline.

Book National Dam Inspection Program  Wadham Creek Dam  NDI PA 00547  PennDer 40 209   Susquehanna River Basin  Wadham Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Wadham Creek Dam NDI PA 00547 PennDer 40 209 Susquehanna River Basin Wadham Creek Luzerne County Pennsylvania Phase I Inspection Report written by GAI CONSULTANTS INC MONROEVILLE PA. and published by . This book was released on 1980 with total page 100 pages. Available in PDF, EPUB and Kindle. Book excerpt: Based on a visual inspection, operational history, and available engineering data, the dam is considered to be in fair condition. The size classification of the facility is small and its hazard classification is considered to be high. In accordance with the recommended guidelines, the Spillway Design Flood (SDF) for the facility ranges between the 1/2-PMF (Probable Maximum Flood) and the PMF. Due to the high potential for damage to downstream structures and possible loss of life that could be associated with a sudden breach of the embankment, the SDF is considered to be the PMF. Results of hydrologic and hydraulic analysis indicate the spillway for Wadham Creek Dam is capable of passing and/or storing the PMF. Consequently, the spillway is considered adequate.

Book Government Reports Announcements   Index

Download or read book Government Reports Announcements Index written by and published by . This book was released on 1979-06 with total page 1152 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book National Dam Inspection Program  Pike Township Municipal Authority Dam  NDS ID PA 00916  PennDer ID 17 111   Susquehanna River Basin  Bear Run  Clearfield County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Pike Township Municipal Authority Dam NDS ID PA 00916 PennDer ID 17 111 Susquehanna River Basin Bear Run Clearfield County Pennsylvania Phase I Inspection Report written by Bernard M. Mihalcin and published by . This book was released on 1979 with total page 84 pages. Available in PDF, EPUB and Kindle. Book excerpt: Bear Run Dam is an earth embankment approximately 42 feet high and 415 feet long (including spillway). The dam is provided with an unlined trapezoidal channel spillway cut into the left abutment. The spillway contains a short concrete control slab adjacent to the embankment crest. The downstream channel of the spillway is comprised of unvegetated granular material. The outlet works consists of a 16-inch diameter ductile iron pipe (blowoff) with a sluice gate located at the inlet and controlled by a manual operator from the dam crest. An 8-inch diameter ductile iron pipe with a perforated vertical intake riser serves as the supply lines are equipped with two gate valves that are manually operated from the crest and downstream slope. Bear Run is located on Bear Run in Pike Township, Clearfield County, Pennsylvania, about 4-1/2 miles west of the community of Bridgeport (located along Anderson Creek) and about 6 miles west of the community of Curwensville.

Book National Dam Inspection Program  Crystal Lake Dam  NDS ID Number 562   Susquehanna River Basin  Wapwallopen Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Crystal Lake Dam NDS ID Number 562 Susquehanna River Basin Wapwallopen Creek Luzerne County Pennsylvania Phase I Inspection Report written by GANNETT FLEMING CORDDRY AND CARPENTER INC HARRISBURG PA. and published by . This book was released on 1978 with total page 89 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367, authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspection of dams throughout the United States. The purpose of the inspection is to determine if the dam constitutes a hazard to human life or property.

Book National Dam Inspection Program  Deep Hollow Dam  NDS PA 00549   DER 40 3   Pennsylvania Gas and Water Company  Susquehanna River Basin  Deep Hollow Run  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Deep Hollow Dam NDS PA 00549 DER 40 3 Pennsylvania Gas and Water Company Susquehanna River Basin Deep Hollow Run Luzerne County Pennsylvania Phase I Inspection Report written by GANNETT FLEMING CORDDRY AND CARPENTER INC HARRISBURG PA. and published by . This book was released on 1978 with total page 85 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Dam Inspection Act, Public Law 92-367, authorized the Secretary of the Army, through the Corps of Engineers, to initiate a program of inspection of dams throughout the United States. The purpose of the inspection is to determine if the dam constitutes a hazard to human life or property.

Book National Dam Inspection Program  Lake Catalpa Dam  NDS ID Number PA 560    DER ID Number 40 57  Susquehanna River Basin  Falls Creek  Luzerne County  Pennsylvania  Phase I Inspection Report

Download or read book National Dam Inspection Program Lake Catalpa Dam NDS ID Number PA 560 DER ID Number 40 57 Susquehanna River Basin Falls Creek Luzerne County Pennsylvania Phase I Inspection Report written by R. Jeffrey Kimball and published by . This book was released on 1980 with total page 77 pages. Available in PDF, EPUB and Kindle. Book excerpt: Lake Catalpa Dam is an earthen embankment with dry masonry walls on both the upstream and downstream sides. Portions of the downstream slope have been replaced with concrete walls. The maximum height is 23 feet. The crest width ranges from 27.5 feet to 30 feet, the crest length is 160 feet. A paved road passes over the crest of the dam. Parapet walls are present both upstream and downstream above the roadway elevation. The reservoir drain is operated by a sluice gate located in the valve house and consists of a 30 in. pipe of unknown material. The spillway is a three sided weir structure placed against the upstream wall with a total crest length of 26 feet. The weir crest is formed by an ogee crest with fish screens along the entire length. The ogee slopes to the entrance of a tunnel through the dam. The tunnel is 6 feet wide and 8.1 feet to 12.7 feet high. The tunnel discharges into an open rectangular shaped channel, at the downstream end of the structure. This rectangular channel continues for about 20 feet where it discharges into a tributary of Leonard Creek. The spillway and reservoir are capable of controlling approximately 33% of the PMF. Based on criteria established by the Corps of Engineers, the spillway is termed inadequate.