EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Imagerie ultrasonore haute r  solution et imagerie volumique

Download or read book Imagerie ultrasonore haute r solution et imagerie volumique written by and published by . This book was released on 2006 with total page 84 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Imagerie ultrasonore haute r  solution et imagerie volumique

Download or read book Imagerie ultrasonore haute r solution et imagerie volumique written by and published by . This book was released on 2006 with total page 84 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Am  lioration de la r  solution en imagerie ultrasonore

Download or read book Am lioration de la r solution en imagerie ultrasonore written by Renaud Morin and published by . This book was released on 2013 with total page 190 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'imagerie ultrasonore est une modalité d'imagerie médicale couramment utilisée pour l'établissement de diagnostics de thérapie ou de suivi divers (croissance du fœtus, détection de certains cancers, assistance à la réalisation d'actes thérapeutiques). Si cette modalité dispose de nombreux avantages comme son innocuité, sa facilité d'utilisation et son faible coût, elle souffre cependant d'une résolution spatiale limitée quand on la compare à d'autres modalités comme l'imagerie par résonance magnétique. L'amélioration de la résolution des images ultrasonores est un défi de taille et de très nombreux travaux ont depuis longtemps exploré des approches instrumentales portant sur l'optimisation du dispositif d'acquisition. L'imagerie échographique haute résolution permet ainsi d'atteindre cet objectif à l'aide de sondes particulières mais se trouve aujourd'hui confrontée à des limitations d'ordre physique et technologique. L'objet de cette thèse est d'adopter une stratégie de post-traitement afin de contourner ces contraintes inhérentes aux approches instrumentales. Dans ce contexte, nous présentons deux approches pour l'amélioration de la résolution des images ultrasonores, selon que les données disponibles prennent la forme d'une séquence d'images ou d'une image unique. Dans le premier cas, l'adaptation d'une technique d'estimation du mouvement originellement proposée pour l'élastographie nous permet d'établir un cadre de reconstruction haute résolution efficace dédié à la modalité qui nous intéresse. Cette approche est évaluée à l'aide d'une simulation réaliste d'images ultrasonores avant d'être appliquée à des données in vivo. Nous proposons ensuite, dans le cadre du traitement d'une seule image, deux méthodes de déconvolution rapide pour l'amélioration de la résolution. Ces approches prennent en compte, suivant leur disponibilité, certaines informations a priori sur les conditions d'acquisition comme la réponse impulsionnelle spatiale du système. Les résultats sont caractérisés dans un premier temps à l'aide de données synthétiques et sont ensuite validés sur des images in vivo

Book Imagerie ultrasonore ultrarapide 4D par adressage orthogonal du r  seau de sonde matricielle

Download or read book Imagerie ultrasonore ultrarapide 4D par adressage orthogonal du r seau de sonde matricielle written by Jack Sauvage and published by . This book was released on 2019 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: Avec l'avènement de l'imagerie ultrarapide 4D au laboratoire Physics for Medecine Inserm 1273, la possibilité d'acquérir dans les trois dimensions et avec une haute résolution spatio-temporelle a été démontrée. Plusieurs des modalités phares de l'imagerie 2D ultrarapide ont pu être étendues à l'imagerie volumique (Doppler de puissance ultrasensible 3D, élastographie 3D ...). Leur dissémination en clinique bénéficierait grandement aux praticiens. Cependant les moyens nécessaires à leur mise en œuvre sont encore trop importants pour espérer une transposition rapide en clinique. Le développant de stratégies intelligentes de réduction de voies est donc devenu un enjeu central. Une stratégie originale basée sur l'architecture de la sonde consiste en l'adressage orthogonal, par lignes et colonnes, du réseau de sonde matricielle, ou Row and Column Adressing RCA. Elle propose une solution transducteur tout à fait adaptée à l'imagerie ultrarapide par ondes planes. Grâce à cette solution, la sonde peut être pilotée par un seul échographe standard, tout en conservant une ouverture d'imagerie étendue. La grille matricielle 2D organisée selon N+N voies orthogonales, représentant ainsi un facteur de réduction de N/2. Cette stratégie présente un changement de paradigme important d'imagerie par dissociation des voies de focalisation en émission et réception et pose un nouveau compromis en termes de résolution spatio-temporelle. Au cours de ces travaux de thèse, les performances de la RCA associées à l'imagerie ultrarapide 4D sont étudiées pour divers cas. Le principe d'imagerie 4D ultrarapide RCA avec sommation orthogonale OPW sont étudié. L'imagerie vectorielle 3D pour la RCA est développée. Un nouveau prototype de sonde RCA haute fréquence (15MHz) est présenté et testé sur un protocole d'imagerie fonctionnelle cérébral en 3D. Enfin une nouvelle modalité d'imagerie 3D d'intensité du flux est présentée offrant un nouveau champ d'exploitation de la sonde RCA.

Book Guide des technologies de l imagerie m  dicale et de la radioth  rapie

Download or read book Guide des technologies de l imagerie m dicale et de la radioth rapie written by Jean-Philippe Dillenseger and published by Elsevier Health Sciences. This book was released on 2024-06-04 with total page 522 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ouvrage de référence pour les utilisateurs d'imageurs médicaux La complexité technique, la spécialisation et l'émergence de nouveaux champs de compétences créent un important besoin d'apprentissage et de formation pour les manipulateurs d'électroradiologie médicale (MERM). Cet ouvrage leur propose ainsi le premier livre de référence complet sur les technologies de l'imagerie médicale et de la radiothérapie. Il est désormais reconnu par tous comme indispensable. Toutes les techniques d'imagerie y sont abordées (radiologie de projection, échographie, TDM, IRM,). La radiothérapie externe, la médecine nucléaire et la radioprotection font l'objet de chapitres dédiés. Remarquablement pédagogique, cet ouvrage offre la possibilité d'une lecture à deux niveaux : • rapide, uniquement sur des éléments essentiels (grâce aux encadrés, aux synthèses, aux tableaux et à la mise en évidence des mots clés mis en gras) ; • plus approfondie, sur des notions plus complexes (grâce à des développements « pour aller plus loin », toujours accompagnés d'exemples pour mieux comprendre). De très nombreuses figures et dessins particulièrement didactiques, illustrent le propos. Cette troisième édition, entièrement révisée, correspond totalement au niveau de connaissances exigé par le référentiel de formation initiale des diplômes préparant à l'exercice de MERM (grade L). Les étudiants en sciences de la santé, en ingénierie ou en sciences biomédicales s'intéressant aux technologies de l'imagerie médicale et de la radiothérapie y trouveront des bases adaptées. Les professionnels de santé de ces secteurs y (re)trouveront les fondamentaux, soit pour entreprendre un changement de spécialisation, soit pour actualiser leurs connaissances. Jean-Philippe Dillenseger, est enseignant-chercheur à la faculté de médecine, maïeutique et des sciences de la santé, de l'université de Strasbourg. Elisabeth Moerschel, Valérie Schmit et Claudine Zorn sont enseignantes pour la section préparant au diplôme de technicien supérieur en imagerie médicale et radiologie thérapeutique (IMRT) au lycée Jean-Rostand de Strasbourg.

Book HIGH RESOLUTION ULTRASONIC APPARATUS FOR IN VIVO SKIN IMAGING

Download or read book HIGH RESOLUTION ULTRASONIC APPARATUS FOR IN VIVO SKIN IMAGING written by Bernard Querleux and published by . This book was released on 1987 with total page 306 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Traitement des signaux d   chographie ultrasonore

Download or read book Traitement des signaux d chographie ultrasonore written by Alain Herment and published by . This book was released on 1984 with total page 181 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Synth  se d ouverture en imagerie ultrasonore large bande

Download or read book Synth se d ouverture en imagerie ultrasonore large bande written by Thierry Rastello and published by . This book was released on 1998 with total page 215 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'imagerie ultrasonore connaît encore actuellement un fort développement dans des domaines aussi variés que l'imagerie médicale, le contrôle non destructif et l'imagerie sous-marine. Notre étude se situe dans le cadre de 1 'imagerie sous-marine par sonar actif large bande. Dans ce domaine, la synthèse d'ouverture est une des voies prometteuses pour réaliser des images sur une longue portée avec une haute résolution spatiale. L'idée directrice de notre travail est d'adapter au domaine du sonar des méthodes de synthèse d'ouverture qui sont opérationnelles en radar. La formation de l'image par ouverture synthétique est d'abord modélisée en large bande dans le cadre de l'analyse de Fourier 2D pour compléter l'analyse spatio-temporelle usuelle. Cette approche nous permet de comparer et de mettre en avant des méthodes de synthèse d'ouverture originales en sonar. Nous montrons l'apport des méthodes d'inversion dans le domaine de Fourier pour le traitement de synthèse d'ouverture des images sonar et pour la prise en compte des deux principales limitations des systèmes sonar à ouverture synthétiques qui sont la faiblesse du taux de couverture et le mouvement du porteur. L'élargissement de la bande de fréquence permet d'améliorer la robustesse des méthodes proposées. La mise en œuvre de ces traitements d'inversion sur des données acquises en cuve ainsi qu'en milieu marin a permis de valider expérimentalement leurs performances ainsi que leurs limitations. Cette étude a été réalisée avec le soutien de la DGA.

Book CONTRIBUTION AU DEVELOPPEMENT DE L IMAGERIE ULTRASONORE HAUTE FREQUENCE APPLICATION A L ETUDE DE L ENDOMMAGEMENT DES MATERIAUX

Download or read book CONTRIBUTION AU DEVELOPPEMENT DE L IMAGERIE ULTRASONORE HAUTE FREQUENCE APPLICATION A L ETUDE DE L ENDOMMAGEMENT DES MATERIAUX written by PIERRE.. JAGNOUX and published by . This book was released on 1992 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: NOUS AVONS MIS AU POINT UN APPAREILLAGE D'ECHOGRAPHIE ULTRASONORE HAUTE FREQUENCE QUI, COUPLE A UN DISPOSITIF DE BALAYAGE ET D'IMMERSION, CONSTITUE UN SYSTEME D'IMAGERIE DE TYPE C-SCAN PRESENTANT UNE RESOLUTION LATERALE DE L'ORDRE DE 100 M DANS L'EAU. DIFFERENTS MODES D'INVESTIGATION DES MATERIAUX, FONDES SUR L'UTILISATION DE FAISCEAUX FOCALISES, ONT ETE ETUDIES: IMAGERIE PAR ONDES DE VOLUME, IMAGERIE PAR ONDES DE SURFACE RAYONNANTES (O.S.R.). DANS CE DERNIER CAS, UNE ATTENTION PARTICULIERE A ETE ATTACHEE A L'ETUDE DES PROPRIETES DES O.S.R. ET DE LEUR INTERACTION AVEC LES DISCONTINUITES ACOUSTIQUES VOISINES DE LA SURFACE. DANS LA DERNIERE PARTIE DE CE TRAVAIL, NOUS AVONS MONTRE L'INTERET QU'IL Y A A UTILISER L'ECHOGRAPHIE ULTRASONORE HAUTE FREQUENCE POUR L'ETUDE DE L'ENDOMMAGEMENT EN SOUS COUCHE DES ROULEMENTS ET DE L'INTERFACE MATRICE-RENFORT D'UN MATERIAU COMPOSITE MONOFILAMENTAIRE AL-SIC

Book Model of image formation and 2D velocity estimation with a high frequency swept scan ultrasound imaging system

Download or read book Model of image formation and 2D velocity estimation with a high frequency swept scan ultrasound imaging system written by Yang Liu Li and published by . This book was released on 2009 with total page 112 pages. Available in PDF, EPUB and Kindle. Book excerpt: In swept-scan ultrasonic imaging system, the single-element transducer continuously moves during emission and reception. It realizes high-frequency (20-50MHz) real-time ultrasound imaging with high spatial resolution. To realize both real-time flow mapping and high-frequency imaging, it is necessary to consider estimating the blood flow 2D velocity with the data of a single image, acquired with a swept-scan transducer. We propose a model of image formation for an ultrasonic broad-band, high frequency, swept-scan transducer system. In a second part, we develop two velocity estimators based firstly on the time-frequency analysis of the “Chirplet signal” in the space-frequency domain and secondly on the 2D Fourier spatial frequency (2DFT) of the system’s PSF. Time-frequency analysis of the “Chirplet signal” is realized with Wigner-Ville Distribution (WVD). The “Chirplet signal” Sf0(u) is the lateral spatial signal chirp signal filtered with the aperture. The analysis of Chirplet’s WVD shows that the centre frequency is directly related to target’s axial velocity, and the compression of the axial bandwidth of WVD depends on target’s lateral relative velocity. 2D Fourier Transform (2DFT) of the system’s PSF shows clearly that the lateral centre frequency is directly related to target’s axial velocity, and the compression of the lateral bandwidth of the system’s 2DFT depends on target’s lateral relative velocity. Simulations of various situations corresponding to real system parameters show the validity of both models. Parabolic flow profiles are also investigated. Mean and standard deviation of the mean error are presented and show a good agreement.

Book Super r  solution pour l am  lioration de la r  solution des images   chographiques

Download or read book Super r solution pour l am lioration de la r solution des images chographiques written by Marie Ploquin and published by . This book was released on 2011 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'imagerie médicale échographique présente plusieurs avantages comme son innocuité, sa facilité d'emploi, la diversité des organes concernés et le faible coût de ce mode d'imagerie. Cependant les images obtenues par échographique souffrent d'une résolution plutôt faible comparées à celle que l'on peut obtenir avec un appareil d'IRM ou en utilisant des rayons X. Le défi majeur de l'échographie médicale est donc de réussir à produire des images avec une résolution beaucoup plus fine, à fréquence nominale fixe.Des travaux ont été entrepris dans ce sens depuis longtemps. Plusieurs pistes ont été explorées. La majorité des travaux effectués jusqu'à présent a consisté à travailler sur l'échographe et particulièrement sur les sondes ultrasonores, avec principalement pour objectif d'augmenter la fréquence des ultrasons utilisés. Cette approche a conduit à l'existence de l'échographie haute résolution, avec cependant une limite importante qui est celle de la profondeur d'exploration.Une autre approche consiste à traiter numériquement des images échographiques classiques pour améliorer leur résolution. Cette méthode a plusieurs avantages, elle permet notamment de contourner la difficulté causée par la réduction de profondeur de champ liée à l'augmentation de la fréquence ultrasonore.Dans cette thèse, nous présentons une méthode permettant d'améliorer la résolution des images échographiques. Le travail de thèse à consister à adapter cette méthode à l'imagerie échographique et à proposer une estimation de la résolution théorique maximale atteinte par cette méthode en fonction de paramètres de l'image dont le SNR, et la largeur de bande de la PSF. Nous avons également proposé une méthode de superrésolution adaptée aux ultrasons. Par son apport sur l'amélioration théorique de la superrésolution et par l'adaptation au cas particulier de l'imagerie ultrasonore, ce travail de thèse ouvre des perspectives sur l'amélioration de la résolution des images échographiques par traitement du signal et de l'image.

Book Transducteurs mono   l  ment pour l imagerie ultrasonore haute r  solution

Download or read book Transducteurs mono l ment pour l imagerie ultrasonore haute r solution written by Pierre Maréchal and published by . This book was released on 2004 with total page 254 pages. Available in PDF, EPUB and Kindle. Book excerpt: Les secteurs d'application de l'imagerie ultrasonore, tels que le diagnostic médical ou le contrôle non destructif, recherchent une amélioration de la résolution. Cette demande se traduit, au niveau des transducteurs, par des spécifications de fréquence centrale élevée et de large bande passante de même que par une forte focalisation. Ici, des moyens de modélisation électro-acoustique du transducteur et du champ rayonné sont mis en place afin de décrire la source focalisée. Afin d'optimiser les propriétés du transducteur multicouche, de nouvelles compositions et techniques de dépôt en film épais de matériaux piézo-électriques sont testées et comparées avec des méthodes de fabrication classiques. Plusieurs transducteurs sont ainsi réalisés, caractérisés, et leurs performances sont comparées aux prévisions théoriques. Enfin, ils sont intégrés dans un système temps-réel d'échographie haute fréquence pour obtenir des images de la peau humaine in vivo.

Book Guidage par l imagerie ultrasonore des traitements par ultrasons focalis  s de haute intensit

Download or read book Guidage par l imagerie ultrasonore des traitements par ultrasons focalis s de haute intensit written by Jérémy Chenot and published by . This book was released on 2011 with total page 0 pages. Available in PDF, EPUB and Kindle. Book excerpt: Cette étude se place dans le cadre du guidage des thérapies par ultrasons focalisés de haute intensité (HIFU). L'utilisation de l'échographie pour le guidage permet une visualisation temps réel mais un faible contraste. Afin de compenser ce manque de vision du traitement, deux études ont été mises en place. La première sur l'utilité de l'élastographie par compression manuelle en temps réel (23 à 60 images par seconde) a été réalisée et validée par deux protocoles in vivo. L'un a été effectué afin de visualiser des tumeurs VX2 dans le foie chez le lapin de manière extracorporelle et per-opératoire en utilisant une sonde de diagnostique linéaire (12MHz). L'autre a été réalisé sur des porcs avec la même sonde et avec une sonde d'imagerie sectorielle (7,5 MHz) placée au centre du transducteur HIFU. Une comparaison a été menée avec des images IRM des mêmes lésions réalisées après prélèvement de l'organe traité. Dans les deux cas, les élastogrammes assurent une meilleure visualisation des dimensions de la lésion (R=0,70) et un contraste plus important (23dB) en comparaison de l'échographie (R=0,65, contraste=3dB). La dernière partie de ces travaux a permis de démontrer que le signal ultrasonore rétrodiffusé par les tissus du foie change avec la température. Lors d'expériences in vitro et in vivo sur du foie de porc, ce changement de signal se corrèle (R=0,85) avec une hausse de température mesurée par un thermocouple positionné dans la zone focale du transducteur. Cette relation est linéaire positive in vitro et négative in vivo. Cette relation permet de calculer des images de température sur une plage de température allant de 20 à 100°C avec une précision de 5°C.

Book Mod  lisation par une m  thode pseudospectrale

Download or read book Mod lisation par une m thode pseudospectrale written by Erwan Filoux and published by . This book was released on 2009 with total page 456 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'imagerie ultrasonore haute résolution est aujourd'hui indispensable à l'établissement de nombreux diagnostics médicaux. Elle est basée sur l'utilisation de transducteurs piézoélectriques haute fréquence (HF) qui sont fabriqués à l'aide de matériaux et de techniques adaptés. L'optimisation de leurs performances nécessite en général l'utilisation de plusieurs modèles numériques pour simuler à la fois la vibration du résonateur et son rayonnement. Ce travail de thèse présente un nouvel algorithme basé sur un couplage pseudospectral / différences-finies, permettant de modéliser la génération et la propagation des ondes acoustiques dans un transducteur et son environnement avec un seul modèle. Cet algorithme hybride a été utilisé pour simuler le fonctionnement de différents transducteurs fabriqués au cours de cette thèse. Les résultats ont été validés de façons théorique et expérimentale, et ils ont permis d'étudier les influences de différents paramètres sur les performances des transducteurs fabriqués.

Book Frontiers of Engineering and Computing in Health Care

Download or read book Frontiers of Engineering and Computing in Health Care written by IEEE Engineering in Medicine and Biology Society. Annual Conference and published by . This book was released on 1984 with total page 872 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Frontiers of Engineering and Computing in Health Care  1984

Download or read book Frontiers of Engineering and Computing in Health Care 1984 written by IEEE Engineering in Medicine and Biology Society. Annual Conference and published by . This book was released on 1984 with total page 892 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Image and Signal Processing

Download or read book Image and Signal Processing written by Abderrahim El Moataz and published by Springer Nature. This book was released on 2020-07-08 with total page 388 pages. Available in PDF, EPUB and Kindle. Book excerpt: This volume constitutes the refereed proceedings of the 9th International Conference on Image and Signal Processing, ICISP 2020, which was due to be held in Marrakesh, Morocco, in June 2020. The conference was cancelled due to the COVID-19 pandemic. The 40 revised full papers were carefully reviewed and selected from 84 submissions. The contributions presented in this volume were organized in the following topical sections: digital cultural heritage & color and spectral imaging; data and image processing for precision agriculture; machine learning application and innovation; biomedical imaging; deep learning and applications; pattern recognition; segmentation and retrieval; mathematical imaging & signal processing.