EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Evaluation of Existing Wells at the Nevada Test Site for Plugging and Abandonment Or for Recompletion as Monitoring Wells

Download or read book Evaluation of Existing Wells at the Nevada Test Site for Plugging and Abandonment Or for Recompletion as Monitoring Wells written by and published by . This book was released on 2001 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: In this investigation, various information sources from the Nevada Test Site (NTS), national laboratories and the Desert Research Institute were utilized to verify the existence of approximately 250 existing wells or boreholes at the NTS. Of these wells, 40 were determined to be located within one kilometer of underground nuclear tests conducted near (within 25 m) or below the water table. These 40 existing wells were then investigated in detail to determine their drilling and construction history, lithology and hydrologic units penetrated, and current conditions. These findings are presented for each well, as well as recommendations as to whether individual wells should be plugged and abandoned or could possibly be recompleted as groundwater quality monitoring locations. Two of the 40 wells, UE-20e and UE-2a, contain lost drilling strings and do not penetrate aquifers. These two wells should be plugged and abandoned and removed from the NTS well inventory. Three other wells, TestWell No. 1, TestWell No. 5, and TestWell No. 6, are reported stemmed with sand to the surface. These three wells did not penetrate the water table and would require substantial deepening to be recompleted as groundwater monitoring locations. If not recompleted, these wells should also be plugged and abandoned and removed from the NTS well inventory. Eleven of the 34 wells, Test Well No. 7, RNM No. 1, RNM No. 2, RNM No. 2S, U-3cn No. 5, UE-20n No. 1, UE-7ns, UE-5n, UE-4t, UE-3e No. 3 and U-15k Test Hole, penetrate aquifers and do not require recompletion to produce groundwater monitoring locations. These wells are either constructed such that recompletion is not needed or not possible. Several of the 11 wells may require the removal of tubing and the placement or replacement of pump equipment. All five of the wells require wellhead rehabilitation to ensure they are not contaminated by surface water or other materials.

Book Evaluation of Existing Wells at the Nevada Test Site for Plugging and Abandonment Or for Recompletion as Monitoring Wells

Download or read book Evaluation of Existing Wells at the Nevada Test Site for Plugging and Abandonment Or for Recompletion as Monitoring Wells written by David Gillespie and published by . This book was released on 1996 with total page 148 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Assessment of the Nevada Test Site Monitoring Well System

Download or read book Assessment of the Nevada Test Site Monitoring Well System written by Charles E. Russell and published by . This book was released on 1991 with total page 174 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Field Investigation at the Faultless Site Central Nevada Test Area

Download or read book Field Investigation at the Faultless Site Central Nevada Test Area written by and published by . This book was released on 1992 with total page 14 pages. Available in PDF, EPUB and Kindle. Book excerpt: An evaluation of groundwater monitoring at non-Nevada Test Site underground nuclear test sites raised questions about the potential for radionuclide migration from the Faultless event and how to best monitor for such migration. With its long standing interest in the Faultless area and background in Nevada hydrogeology, the Desert Research Institute conducted a field investigation in FY92 to address the following issues: The status of chimney infilling (which determines the potential for migration); the best level(s) from which to collect samples from the nearby monitoring wells, HTH-1 and HTH-2; the status of hydraulic heads in the monitoring well area following records of sustained elevated post-shot heads. The field investigation was conducted from July 27 to 31 and August 4 to 7, 1992. Temperature and electrical conductivity logging were performed in HTH-1, HTH-2, and UC-1-P-2SR. Water samples were collected from HTH-1 and HTH-2. Lawrence Livermore National Laboratory (LLNL) also collected samples during the July trip, including samples from UC-1-P-2SR. This report presents the data gathered during these field excursions and some preliminary conclusions. Full interpretation of the data in light of the issues listed above is planned for FY93.

Book Nevada Test Site Water supply Wells

Download or read book Nevada Test Site Water supply Wells written by and published by . This book was released on 1996 with total page 80 pages. Available in PDF, EPUB and Kindle. Book excerpt: A total of 15 water-supply wells are currently being used at the Nevada Test Site (NTS). The purpose of this report is to bring together the information gleaned from investigations of these water-supply wells. This report should serve as a reference on well construction and completion, static water levels, lithologic and hydrologic characteristics of aquifers penetrated, and general water quality of water-supply wells at the NTS. Possible sources for contamination of the water-supply wells are also evaluated. Existing wells and underground nuclear tests conducted near (within 25 meters (m)) or below the water table within 2 kilometers (km) of a water-supply were located and their hydrogeologic relationship to the water-supply well determined.

Book Publications of the Water Resources Center

Download or read book Publications of the Water Resources Center written by University and Community College System of Nevada. Water Resources Center and published by . This book was released on 1997 with total page 128 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Desert Research Institute Publications of the Water Resources Center

Download or read book Desert Research Institute Publications of the Water Resources Center written by University of Nevada System. Water Resources Center and published by . This book was released on 1991-08 with total page 128 pages. Available in PDF, EPUB and Kindle. Book excerpt: Price list of available publications.

Book Recompletion Report for Well UE 10j

Download or read book Recompletion Report for Well UE 10j written by and published by . This book was released on 2000 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt: Existing Well UE-10j was deepened and recompleted for the U.S. Department of Energy, Nevada Operations Office in support of the Nevada Environmental Restoration Project at the Nevada Test Site, Nye County, Nevada. The well was originally drilled to a total depth of 725.4 meters in 1965 for use as a hydrologic test hole in the northern portion of Yucca Flat in Area 8 of the Nevada Test Site. The well is located up-gradient of the Yucca Flat underground test area and penetrates deep into the Paleozoic rocks that form the lower carbonate aquifer of the NTS and surrounding areas. The original 24.4-centimeter-diameter borehole was drilled to a depth of 725.4 meters and left uncompleted. Water-level measurements were made periodically by the U.S. Geological Survey, but access to the water table was lost between 1979 and 1981 due to hole sloughing. In 1993, the hole was opened to 44.5 centimeters and cased off to a depth of 670.0 meters. The hole diameter was then decreased to 31.1 centimeters for drilling to a total depth of 796.4 meters. The depth to water in the open borehole was measured at 658.7 meters on March 18, 1993.

Book Hydrogeologic Characterization of Wells HTH 1  UE18r  UE6e  and HTH 3  Nevada Test Site

Download or read book Hydrogeologic Characterization of Wells HTH 1 UE18r UE6e and HTH 3 Nevada Test Site written by and published by . This book was released on 1991 with total page 73 pages. Available in PDF, EPUB and Kindle. Book excerpt: Monitoring for the migration of contaminants in groundwater or for the proper design of nuclear test emplacement holes at the Nevada Test Site (NTS) requires proper placement and completion of monitoring wells. This is only possible if the hydrogeologic system is understood in a regional and local context, necessitating data from existing wells and boreholes. Though the NTS Groundwater Characterization Project will be drilling wells, their great expense limits the number of new wells. However, there are many existing boreholes and wells on the NTS which have not been completely evaluated hydrologically. Some of these are incorporated in the Long Term Hydrologic Monitoring Program (LTHMP) of the US Environmental Protection Agency (EPA), others are related to the testing programs. In all cases, additional site investigation in necessary to properly interpret the hydrogeologic data from these wells. Monitoring wells on the NTS are poorly characterized with regard to aquifers penetrated, vertical hydraulic gradients, and vertical variations in water quality. One of the goals of the well validation program was to gain a thorough understanding of the parameters needed to interpret the source and fate potential hazardous and radioactive substances that may be detected in these wells in the future. One of the most critical parameters for monitoring is the knowledge of what aquifer or geologic unit is being sampled when a water sample is collected. Pumped water samples are weighted most heavily to the water quality of the most productive (highest transmissivity) aquifer penetrated by the well.

Book Publications of the Water Resources Center

Download or read book Publications of the Water Resources Center written by University of Nevada System. Center for Water Resources Research and published by . This book was released on 1998 with total page 74 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Nevada Test Site Groundwater Well Rehabilitation Plan

Download or read book Nevada Test Site Groundwater Well Rehabilitation Plan written by David B. Hudson and published by . This book was released on 2006 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This plan describes actions to improve the utility and credibility of the Nevada Test Site (NTS) interim groundwater monitoring program. The two principal actions are: (1) well maintenance/rehabilitation activities and (2) the deployment of dedicated low-cost and reliable jack-pumps for groundwater sampling from deep monitoring wells. The scope of this proposal is to perform these actions on some number of nine selected wells (Figure 1) to evaluate whether these actions are achievable, practical, cost effective, and result in improved groundwater data quality.

Book Long term Monitoring Plan for the Central Nevada Test Area

Download or read book Long term Monitoring Plan for the Central Nevada Test Area written by Ahmed E. Hassan and published by . This book was released on 2003 with total page 56 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Well Completion Report for Corrective Action Unit 443 Central Nevada Test Area Nye County  Nevada

Download or read book Well Completion Report for Corrective Action Unit 443 Central Nevada Test Area Nye County Nevada written by and published by . This book was released on 2009 with total page 66 pages. Available in PDF, EPUB and Kindle. Book excerpt: The drilling program described in this report is part of a new corrective action strategy for Corrective Action Unit (CAU) 443 at the Central Nevada Test Area (CNTA). The drilling program included drilling two boreholes, geophysical well logging, construction of two monitoring/validation (MV) wells with piezometers (MV-4 and MV-5), development of monitor wells and piezometers, recompletion of two existing wells (HTH-1 and UC-1-P-1S), removal of pumps from existing wells (MV-1, MV-2, and MV-3), redevelopment of piezometers associated with existing wells (MV-1, MV-2, and MV-3), and installation of submersible pumps. The new corrective action strategy includes initiating a new 5-year proof-of-concept monitoring period to validate the compliance boundary at CNTA (DOE 2007). The new 5-year proof-of-concept monitoring period begins upon completion of the new monitor wells and collection of samples for laboratory analysis. The new strategy is described in the Corrective Action Decision Document/Corrective Action Plan addendum (DOE 2008a) that the Nevada Division of Environmental Protection approved (NDEP 2008).

Book Project Rulison

Download or read book Project Rulison written by United States. Energy Research and Development Administration. Nevada Operations Office and published by . This book was released on 1976 with total page 106 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Completion Report for Well ER EC 8

Download or read book Completion Report for Well ER EC 8 written by Bechtel Nevada (Firm) and published by . This book was released on 2004 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Well ER-EC-8 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of the Nevada Environmental Restoration Project at the Nevada Test Site, Nye County, Nevada. This well was drilled in the summer of 1999 as part of the U.S. Department of Energy's hydrogeologic investigation program in the Western Pahute Mesa - Oasis Valley region just west of the Nevada Test Site. A 44.5-centimeter surface hole was drilled and cased off to a depth of 129.8 meters below the surface. The hole diameter was then decreased to 31.1 centimeters for drilling to a total depth of 609.6 meters. One completion string with three isolated slotted intervals was installed in the well. A preliminary composite, static water level was measured at the depth of 98.4 meters, 24 days after installation of the completion string. Detailed lithologic descriptions with stratigraphic assignments are included in the report. These are based on evaluation of composite drill cuttings collected every 3 meters, and 20 sidewall samples taken at various depths below 157.9 meters, supplemented by geophysical log data and results of detailed chemical and mineralogical studies of rock samples. Drilling began in Tertiary-age tuff of the Thirsty Canyon Group, and penetrated tuffs of the Beatty Wash Formation, tuff of Buttonhook Wash, and the upper portion of the Ammonia Tanks Tuff. The geologic interpretation of data from this well helps define the location of the western margin of the Timber Mountain caldera complex in the southwestern Nevada volcanic field. Geologic and hydrologic data from the well will aid in development of models to predict groundwater flow and contaminant migration within and near the Nevada Test Site.