EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book UN SYSTEME INFORMATIQUE POUR L ACQUISITION ET LE TRAITEMENT DES DONNEES EN MICROSCOPIE ELECTRONIQUE

Download or read book UN SYSTEME INFORMATIQUE POUR L ACQUISITION ET LE TRAITEMENT DES DONNEES EN MICROSCOPIE ELECTRONIQUE written by Marcel Tencé and published by . This book was released on 1987 with total page 108 pages. Available in PDF, EPUB and Kindle. Book excerpt: GESTION DES PARAMETRES D'ACQUISITION DES DONNEES A TRAVERS LE CONTROLE DE CERTAINES COMMANDES DU MICROSCOPE ARCHIVAGE DES RESULTATS ET LEUR TRAITEMENT A POSTERIORI. APPLICATION A LA DETERMINATION EN LIGNE DE LA DIMENSION FRACTALE DE FAMILLES D'AGREGATS

Book   tude et r  alisation d un syst  me de traitement des images adapt      la microscopie   lectronique    balayage

Download or read book tude et r alisation d un syst me de traitement des images adapt la microscopie lectronique balayage written by José Maldonado and published by . This book was released on 1987 with total page 189 pages. Available in PDF, EPUB and Kindle. Book excerpt: LE TRAVAIL EST CONSACRE A L'ETUDE D'UN SYSTEME DE TRAITEMENT DES IMAGES PERMETTANT DE REALISER L'ACQUISITION ET L'INTEGRATION NUMERIQUE D'IMAGES VIDEO TV, D'IMAGES ELECTRONIQUES ET X ISSUES D'UN ENSEMBLE DE MICROSCOPIE ET D'ANALYSE ET LEUR VISUALISATION A L'AIDE D'UNE MEMOIRE D'IMAGES. ON DECRIT L'ARCHITECTURE DU SYSTEME ET LE LOGICIEL DE TRAITEMENT DES IMAGES

Book METHODOLOGIE DE CONCEPTION DE SYSTEMES D ANALYSE D IMAGES

Download or read book METHODOLOGIE DE CONCEPTION DE SYSTEMES D ANALYSE D IMAGES written by Jean-Michel Jolion and published by . This book was released on 1987 with total page 266 pages. Available in PDF, EPUB and Kindle. Book excerpt: ON EXPOSE UNE METHODOLOGIE PRENANT EN COMPTE LES CONNAISSANCES ET L'EXPERIENCE DE L'HOMME POUR DEVELOPPER L'ADAPTABILITE DES SYSTEMES D'ANALYSE D'IMAGES. ON REALISE A L'USAGE DES UTILISATEURS PHYSICIENS DANS LE CONTEXTE DE LA MICROSCOPIE ELECTRONIQUE LE SYSTEME D'ANALYSE D'IMAGES CELLULE QUI UTILISE LE LANGAGE ESSAI

Book Microscopie   lectronique    transmission en haute r  solution num  rique et quantitative

Download or read book Microscopie lectronique transmission en haute r solution num rique et quantitative written by Henri Souchay and published by . This book was released on 1999 with total page 199 pages. Available in PDF, EPUB and Kindle. Book excerpt: Dans le contexte actuel de la microscopie à transmission quantitative a haute résolution, ce travail se propose de faire le lien entre les manipulations expérimentales et les analyses quantitatives auxquelles elles peuvent donner lieu. Pour y parvenir, trois éléments sont nécessaires : une théorie de la formation de l'image qui puisse donner lieu à des calculs numériques assez rapides ; un détecteur d'images électroniques performant ; et un outil logiciel permettant l'acquisition et le traitement des images, leur comparaison avec des simulations et les outils de base pour des reconstructions. Les principaux aspects de la formation d'image en haute résolution sont repris dans le premier chapitre, avec des rappels importants, et un calcul de l'image développe jusqu'aux effets non linéaires et la cohérence partielle pour des défauts cristallins. Dans le second chapitre, après un état de l'art des capteurs d'images électroniques, la propagation est décrite en détail, notamment les effets de l'étalement du signal sur sa variance. Le résultat montre que le bruit crée par la double scintillation était jusque-là sous-estime. Le développement d'une caméra, associe à ce travail, permet de présenter les méthodes de caractérisation de ce type de capteur, en insistant sur la distinction entre le transfert du bruit et du signal. Enfin, le dernier chapitre présente un cahier des charges pour le logiciel et explicite certains des algorithmes utilises, avant de proposer quelques applications : corrections du transfert dans la camera, alignement d'images, et application de la méthode des phases géométriques

Book Conception et r  alisation du syst  me de traitement num  rique d images LAE980

Download or read book Conception et r alisation du syst me de traitement num rique d images LAE980 written by Bernard Keith and published by . This book was released on 1976 with total page 36 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book ETUDE D UN SYSTEME DE NUMERISATION D IMAGE HAUTE DEFINITION

Download or read book ETUDE D UN SYSTEME DE NUMERISATION D IMAGE HAUTE DEFINITION written by Serge Ponzio and published by . This book was released on 1987 with total page 165 pages. Available in PDF, EPUB and Kindle. Book excerpt: LE SYSTEME DEVELOPPE UTILISE DES BARETTES DE PHOTODIODES DE 2048 OU 4096 ELEMENTS SE DEPLACANT DEVANT LE DOCUMENT A NUMERISER. LES CARTES NECESSAIRES ONT ETE DEVELOPPEES DANS LE CADRE DU SYSTEME MULTIBUS II DE LA SOCIETE INTEL : UNE CARTE D'ACQUISITION D'IMAGE, UNE CARTE DE MEMORISATION D'IMAGE, UNE CARTE GESTION DE DEPLACEMENT, UNE CARTE DE VISUALISATION D'IMAGE. DES EXEMPLES DE TRAITEMENT D'IMAGES OBTENUES EN MICROSCOPIE ELECTRONIQUE SONT DONNES

Book Traitement des signaux et acquisition de donn  es

Download or read book Traitement des signaux et acquisition de donn es written by Francis Cottet and published by Dunod. This book was released on 2020-05-20 with total page 432 pages. Available in PDF, EPUB and Kindle. Book excerpt: Cet ouvrage présente les principales caractéristiques de la conception puis de la réalisation d'une chaîne de mesures d'un procédé physique. La première partie décrit le traitement des signaux analogiques. La deuxième est consacrée au traitement des signaux numériques. Enfin, la troisième traite de l'acquisition de données et du choix et de la mise en oeuvre d'une chaîne de mesures. De nombreux exercices et problèmes résolus complètent chaque chapitre. Les exemples de l'ouvrage sont illustrés à l'aide du logiciel d'instrumentation industrielle LabVIEW. Cette cinquième édition met à jour en profondeur la troisième partie, et se voit agrémentée d'un chapitre sur la transmission des données numériques.

Book ACQUISITION DES IMAGES EN MICROSCOPIE ELECTRONIQUE A BALAYAGE IN SITU

Download or read book ACQUISITION DES IMAGES EN MICROSCOPIE ELECTRONIQUE A BALAYAGE IN SITU written by Hervé Le Floch and published by . This book was released on 1986 with total page 178 pages. Available in PDF, EPUB and Kindle. Book excerpt: CHAINE D'ACQUISITION DU SIGNAL IMAGE DU MEBIS. ETUDE DES SOURCES DE BRUIT ASSOCIEES AUX DETECTEURS A SEMICONDUCTEUR ET MISE AU POINT D'UN PROCESSUS DE REALISATION DE DIODES DE DETECTION A BARRIERE DE SURFACE. CONCEPTION D'UNE CARTE ELECTRONIQUE COMPATIBLE AVEC UN MICROORDINATEUR. CETTE CARTE PERMET LA NUMERISATION, LE STOCKAGE SUR DISQUETTE ET LA VISUALISATION DES IMAGES FOURNIES PAR LE MEBIS

Book Microscopie electronique selective en transmission   contribution a l etude de l ordre dans la matiere

Download or read book Microscopie electronique selective en transmission contribution a l etude de l ordre dans la matiere written by SERGE GALAUP and published by . This book was released on 1996 with total page 175 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ADAPTATION SUR LES MICROSCOPES ELECTRONIQUES EN TRANSMISSION DE SYSTEMES DISPERSIFS EN ENERGIE D'ELECTRONS ET DE NOUVEAUX DISPOSITIFS DE DETECTION (SYSTEMES SCINTILLATEUR-PHOTOMULTIPLICATEUR, RESEAUX DE PHOTODIODES OU CCD) PERMET D'ENVISAGER UNE DETERMINATION QUANTITATIVE PRECISE DE LA CONTRIBUTION DES PROCESSUS DE DIFFUSION ELASTIQUE ET INELASTIQUE A LA FORMATION DES IMAGES ET DES DIAGRAMMES DE DIFFRACTION ELECTRONIQUE. ELLE CONSTITUE UNE ETAPE ESSENTIELLE POUR LA CONNAISSANCE DE L'ORDRE DANS LA MATIERE A L'ECHELLE ATOMIQUE. LE DEVELOPPEMENT RECENT DE SYSTEMES DE FILTRAGE D'IMAGES CONFIRME CET INTERET, CEPENDANT LES SYSTEMES PROPOSES RESTENT ONEREUX ET SONT ENCORE PEU ACCESSIBLES. A PARTIR D'UN SYSTEME DISPERSIF CONSTITUE D'UN PRISME MAGNETIQUE, DISPOSE SOUS LA COLONNE D'UN MICROSCOPE, NOUS AVONS DEVELOPPE UN SYSTEME DE FILTRAGE EN ENERGIE DES INTENSITES. IL EST EXPLOITABLE LORSQUE L'INFORMATION UTILE EST DISTRIBUEE SUIVANT UNE DIRECTION COMME C'EST LE CAS DANS LES DIAGRAMMES DE DIFFRACTION ELECTRONIQUE OU DANS LES IMAGES DE RESEAUX DE FRANGES ET D'INTERFACES. DANS NOTRE MONTAGE LE MICROSCOPE EST PILOTE PAR UN MICROORDINATEUR QUI PERMET DE COMMANDER LA DEFLEXION DU DIAGRAMME OU DE L'IMAGE DEVANT L'OUVERTURE D'ENTREE DU SPECTROMETRE UTILISE COMME MONOCHROMATEUR. CET ORDINATEUR EST INTERFACE AVEC LE SPECTROMETRE POUR L'ACQUISITION ET LE TRAITEMENT DES DONNEES. LE SYSTEME DE COMPTAGE SCINTILLATEUR-PHOTOMULTIPLICATEUR POSSEDE UNE DYNAMIQUE SUFFISAMMENT LARGE (6 DECADES) POUR PERMETTRE LE TRAITEMENT DE LA PLUPART DES TYPES DE PROFILS D'INTENSITE OBTENUS A PARTIR DES IMAGES OU DES DIAGRAMMES. LE SYSTEME PEUT ETRE UTILISE POUR ETUDIER LES PROCESSUS DE DIFFUSION ELASTIQUE ET INELASTIQUE ET LEUR CONTRIBUTION A LA FORMATION DES IMAGES ET DES DIAGRAMMES DE DIFFRACTION. UNE DES APPLICATIONS IMPORTANTES DE CE DISPOSITIF CONCERNE LA DETERMINATION DE L'ORDRE A COURTE DISTANCE DANS LES MATERIAUX AMORPHES OU POLYCRISTALLINS. ELLE PEUT ETRE FAITE AVEC UNE PRECISION DE 3.10#-#3 NM POUR DES VALEURS DE CES DISTANCES ALLANT JUSQU'A 1,2 NM. ELLE A ETE UTILISEE POUR L'ETUDE DE MATERIAUX CERAMIQUES.

Book Formation et restauration d images en microscopie    rayons

Download or read book Formation et restauration d images en microscopie rayons written by Jean-Baptiste Sabarita and published by . This book was released on 1996 with total page 215 pages. Available in PDF, EPUB and Kindle. Book excerpt: Technique récente, la microscopie à rayons X offre aujourd'hui une résolution spatiale supérieure à celle de la microscopie optique (20 nm contre 200 nm en microscopie optique confocal laser). Elle offre également un meilleur pouvoir de pénétration que la microscopie électronique (jusqu'à 10 μm contre 1 μm en microscopie électronique à moyenne et haute tension). Ainsi, la microscopie à rayons X mous (longueurs d'onde comprises entre 2,4 et 4,3 nanomètres) permet l'analyse à haute résolution en 2 ou 3 dimensions d'échantillons biologiques placés dans des conditions proches de leur milieu naturel (contrairement aux microscopes électroniques classiques qui imposent une préparation des échantillons). Cependant, la réduction de la dose absorbée par l'échantillon nécessite des durées d'expositions aussi courtes que possible. Or, effectuer une acquisition avec peu de photons se fait au détriment du rapport signal sur bruit des images. Un de nos objectifs a été le développement d'outils pour l'amélioration et la restauration de ces images. La première partie de nos travaux a consisté à déterminer la fonction de transfert du microscope à rayons X en transmission et à comparer les résultats obtenus avec le modèle théorique de la formation des images. Dans la seconde partie, nous avons complété les modèles existants liant le nombre de photons et le contraste, en prenant en compte le mode de formation des images dans le microscope. La troisième partie de ces travaux concerne le développement de techniques de traitement numérique des images dans le but d'améliorer et de restaurer des images obtenues par microscopie à rayons X avec de faibles temps d'exposition. Ces processus ont été appliqués à l'étude par microscopie à rayons X de différents types d'échantillons biologiques

Book R  alisation d un syst  me microinformatique d acquisition et de traitement num  rique de spectres R P E

Download or read book R alisation d un syst me microinformatique d acquisition et de traitement num rique de spectres R P E written by Omar Nadjemi (auteur d'une thèse de sciences.) and published by . This book was released on 1981 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Microscopie   lectronique s  lective en transmission  Contribution    l   tude de l ordre dans la mati  re

Download or read book Microscopie lectronique s lective en transmission Contribution l tude de l ordre dans la mati re written by Serge Galaup and published by . This book was released on 1996 with total page 161 pages. Available in PDF, EPUB and Kindle. Book excerpt: L'ADAPTATION SUR LES MICROSCOPES ELECTRONIQUES EN TRANSMISSION DE SYSTEMES DISPERSIFS EN ENERGIE D'ELECTRONS ET DE NOUVEAUX DISPOSITIFS DE DETECTION (SYSTEMES SCINTILLATEUR-PHOTOMULTIPLICATEUR, RESEAUX DE PHOTODIODES OU CCD) PERMET D'ENVISAGER UNE DETERMINATION QUANTITATIVE PRECISE DE LA CONTRIBUTION DES PROCESSUS DE DIFFUSION ELASTIQUE ET INELASTIQUE A LA FORMATION DES IMAGES ET DES DIAGRAMMES DE DIFFRACTION ELECTRONIQUE. ELLE CONSTITUE UNE ETAPE ESSENTIELLE POUR LA CONNAISSANCE DE L'ORDRE DANS LA MATIERE A L'ECHELLE ATOMIQUE. LE DEVELOPPEMENT RECENT DE SYSTEMES DE FILTRAGE D'IMAGES CONFIRME CET INTERET, CEPENDANT LES SYSTEMES PROPOSES RESTENT ONEREUX ET SONT ENCORE PEU ACCESSIBLES. A PARTIR D'UN SYSTEME DISPERSIF CONSTITUE D'UN PRISME MAGNETIQUE, DISPOSE SOUS LA COLONNE D'UN MICROSCOPE, NOUS AVONS DEVELOPPE UN SYSTEME DE FILTRAGE EN ENERGIE DES INTENSITES. IL EST EXPLOITABLE LORSQUE L'INFORMATION UTILE EST DISTRIBUEE SUIVANT UNE DIRECTION COMME C'EST LE CAS DANS LES DIAGRAMMES DE DIFFRACTION ELECTRONIQUE OU DANS LES IMAGES DE RESEAUX DE FRANGES ET D'INTERFACES. DANS NOTRE MONTAGE LE MICROSCOPE EST PILOTE PAR UN MICROORDINATEUR QUI PERMET DE COMMANDER LA DEFLEXION DU DIAGRAMME OU DE L'IMAGE DEVANT L'OUVERTURE D'ENTREE DU SPECTROMETRE UTILISE COMME MONOCHROMATEUR. CET ORDINATEUR EST INTERFACE AVEC LE SPECTROMETRE POUR L'ACQUISITION ET LE TRAITEMENT DES DONNEES. LE SYSTEME DE COMPTAGE SCINTILLATEUR-PHOTOMULTIPLICATEUR POSSEDE UNE DYNAMIQUE SUFFISAMMENT LARGE (6 DECADES) POUR PERMETTRE LE TRAITEMENT DE LA PLUPART DES TYPES DE PROFILS D'INTENSITE OBTENUS A PARTIR DES IMAGES OU DES DIAGRAMMES. LE SYSTEME PEUT ETRE UTILISE POUR ETUDIER LES PROCESSUS DE DIFFUSION ELASTIQUE ET INELASTIQUE ET LEUR CONTRIBUTION A LA FORMATION DES IMAGES ET DES DIAGRAMMES DE DIFFRACTION. UNE DES APPLICATIONS IMPORTANTES DE CE DISPOSITIF CONCERNE LA DETERMINATION DE L'ORDRE A COURTE DISTANCE DANS LES MATERIAUX AMORPHES OU POLYCRISTALLINS. ELLE PEUT ETRE FAITE AVEC UNE PRECISION DE 3.10#-#3 NM POUR DES VALEURS DE CES DISTANCES ALLANT JUSQU'A 1,2 NM. ELLE A ETE UTILISEE POUR L'ETUDE DE MATERIAUX CERAMIQUES

Book CONCEPTION ET REALISATION D UN SYSTEME D ACQUISITION ANALOGIQUE NUMERIQUE RAPIDE A HAUTES PERFORMANCES

Download or read book CONCEPTION ET REALISATION D UN SYSTEME D ACQUISITION ANALOGIQUE NUMERIQUE RAPIDE A HAUTES PERFORMANCES written by Laurent Dukan and published by . This book was released on 1985 with total page 224 pages. Available in PDF, EPUB and Kindle. Book excerpt: PRINCIPES ET PERFORMANCES DES CONVERTISSEURS AN RAPIDES. LES DIVERS MODES DE CONVERSION, LES SYSTEMES D'ACQUISITION A/N RAPIDES COMMERCIALISES. ETUDE DE LA CARTE MEMOIRE, DE LA CARTE LOGIQUE ECL ET DE LA CARTE LOGIQUE TTL

Book Les techniques r  centes en microscopie   lectronique et corpusculaire

Download or read book Les techniques r centes en microscopie lectronique et corpusculaire written by Centre national de la recherche scientifique and published by FeniXX. This book was released on 1956-01-01T00:00:00+01:00 with total page 422 pages. Available in PDF, EPUB and Kindle. Book excerpt: Cet ouvrage est une réédition numérique d’un livre paru au XXe siècle, désormais indisponible dans son format d’origine.