EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book Cold Vacuum Drying  CVD  Facility Hazards Analysis Report

Download or read book Cold Vacuum Drying CVD Facility Hazards Analysis Report written by and published by . This book was released on 2003 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This report describes the methodology used in conducting the Cold Vacuum Drying Facility (CVDF) Hazard Analysis to support the CVDF Final Safety Analysis Report and documents the results. The hazard analysis was performed in accordance with DOE-STD-3009-94, ''Preparation Guide for US. Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports, '' and implements the requirements of DOE Order 5480.23, ''Nuclear Safety Analysis Reports.''

Book Fire Hazard Analysis for the Cold Vacuum Drying  CVD  Facility

Download or read book Fire Hazard Analysis for the Cold Vacuum Drying CVD Facility written by and published by . This book was released on 1999 with total page 339 pages. Available in PDF, EPUB and Kindle. Book excerpt: This Fire Hazard Analysis assesses the risk from fire within individual fire areas in the Cold Vacuum Drying Facility at the Hanford Site in relation to existing or proposed fire protection features to ascertain whether the objectives of DOE Order 5480.7A Fire Protection are met.

Book Cold Vacuum Drying Facility Hazard Analysis Report

Download or read book Cold Vacuum Drying Facility Hazard Analysis Report written by and published by . This book was released on 1998 with total page 99 pages. Available in PDF, EPUB and Kindle. Book excerpt: This report describes the methodology used in conducting the Cold Vacuum Drying Facility (CVDF) hazard analysis to support the CVDF phase 2 safety analysis report (SAR), and documents the results. The hazard analysis was performed in accordance with DOE-STD-3009-94, Preparation Guide for US Department of Energy Nonreactor Nuclear Facility Safety Analysis Reports, and implements the requirements of US Department of Energy (DOE) Order 5480.23, Nuclear Safety Analysis Reports.

Book Cold Vacuum Drying  CVD  Facility Design Basis Accident Analysis Documentation

Download or read book Cold Vacuum Drying CVD Facility Design Basis Accident Analysis Documentation written by and published by . This book was released on 1999 with total page 400 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the detailed accident analysis to support HNF-3553, Annex B, Spent Nuclear Fuel Project Final Safety Analysis Report (FSAR), ''Cold Vacuum Drying Facility Final Safety Analysis Report.'' All assumptions, parameters, and models used to provide the analysis of the design basis accidents are documented to support the conclusions in the FSAR. The calculations in this document address the design basis accidents (DBAs) selected for analysis in HNF-3553, ''Spent Nuclear Fuel Project Final Safety Analysis Report'', Annex B, ''Cold Vacuum Drying Facility Final Safety Analysis Report.'' The objective is to determine the quantity of radioactive particulate available for release at any point during processing at the Cold Vacuum Drying Facility (CVDF) and to use that quantity to determine the amount of radioactive material released during the DBAs. The radioactive material released is used to determine dose consequences to receptors at four locations, and the dose consequences are compared with the appropriate evaluation guidelines and release limits to ascertain the need for preventive and mitigative controls.

Book Estampes par

    Book Details:
  • Author :
  • Publisher :
  • Release : 1918
  • ISBN :
  • Pages : pages

Download or read book Estampes par written by and published by . This book was released on 1918 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Fire Hazard Analysis for the Cold Vacuum Drying Facility  CVD  Facility

Download or read book Fire Hazard Analysis for the Cold Vacuum Drying Facility CVD Facility written by and published by . This book was released on 2000 with total page 346 pages. Available in PDF, EPUB and Kindle. Book excerpt: The CVDF is a nonreactor nuclear facility that will process the Spent Nuclear Fuels (SNF) presently stored in the 105-KE and 105-KW SNF storage basins. Multi-canister overpacks (MCOs) will be loaded (filled) with K Basin fuel transported to the CVDF. The MCOs will be processed at the CVDF to remove free water from the fuel cells (packages). Following processing at the CVDF, the MCOs will be transported to the CSB for interim storage until a long-term storage solution can be implemented. This operation is expected to start in November 2000. A Fire Hazard Analysis (FHA) is required for all new facilities and all nonreactor nuclear facilities, in accordance with U.S. Department of Energy (DOE) Order 5480.7A, Fire Protection. This FHA has been prepared in accordance with DOE 5480.7A and HNF-PRO-350, Fire Hazard Analysis Requirements. Additionally, requirements or criteria contained in DOE, Richland Operations Office (RL) RL Implementing Directive (RLID) 5480.7, Fire Protection, or other DOE documentation are cited, as applicable. This FHA comprehensively assesses the risk of fire at the CVDF to ascertain whether the specific objectives of DOE 5480.7A are met. These specific fire protection objectives are: (1) Minimize the potential for the occurrence of a fire. (2) Ensure that fire does not cause an onsite or offsite release of radiological and other hazardous material that will threaten the public health and safety or the environment. (3) Establish requirements that will provide an acceptable degree of life safety to DOE and contractor personnel and ensure that there are no undue hazards to the public from fire and its effects in DOE facilities. (4) Ensure that vital DOE programs will not suffer unacceptable delays as a result of fire and related perils. (5) Ensure that property damage from fire and related perils does not exceed an acceptable level. (6) Ensure that process control and safety systems are not damaged by fire or related perils. This FHA is based on the facility as constructed and with planned operation at the time of document preparation. Changes in facility planned and actual operation require that the identified fire risks associated with the CVDF be re-evaluated. Consequently, formal documentation and future revision of this FHA may be required.

Book Cold Vacuum Drying  CVD  Facility Safety Class Instrumentation   Control System Design Description

Download or read book Cold Vacuum Drying CVD Facility Safety Class Instrumentation Control System Design Description written by and published by . This book was released on 1999 with total page 71 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document describes the Cold Vacuum Drying Facility (CVDF) Safety Class Instrumentation and Control system (SCIC). The SCIC provides safety functions and features to protect the environment, off-site and on-site personnel and equipment. The function of the SCIC is to provide automatic trip features, valve interlocks, alarms, indication and control for the cold vacuum drying process.

Book Cold Vacuum Drying  CVD  Facility Sampling and Analysis Plan

Download or read book Cold Vacuum Drying CVD Facility Sampling and Analysis Plan written by and published by . This book was released on 2000 with total page 20 pages. Available in PDF, EPUB and Kindle. Book excerpt: The Cold Vacuum Drying (CVD) Facility provides the required process systems, supporting equipment, and facilities needed for the conditioning of spent nuclear fuel (SNF) from the Hanford K-Basins prior to storage at the Canister Storage Building (CSB). The process water conditioning (PWC) system collects and treats the selected liquid effluent streams generated by the CVD process. The PWC system uses ion exchange modules (IXMs) and filtration to remove radioactive ions and particulate from CVD effluent streams. Water treated by the PWC is collected in a 5000-gallon storage tank prior to shipment to an on-site facility for additional treatment and disposal. The purpose of this sampling and analysis plan is to document the basis for achieving the following data quality objectives: (1) Measurement of the radionuclide content of the water transferred from the multi-canister overpack (MCO), vacuum purge system (VPS) condensate tank, MCO/Cask annulus and deionized water flushes to the PWC system receiver tanks. (2) Trending the radionuclide inventory of IXMs to assure that they do not exceed the limits prescribed in HNF-2760, Rev. 0-D, ''Safety Analysis Report for Packaging (Onsite) Ion Exchange Modules, '' and HNF-EP-0063 Rev. 5, ''Hanford Site Solid Waste Acceptance Criteria'' for Category 3, non-TRU, low level waste (LLW). (3) Determining the radionuclide content of the PWC system bulk water storage tank to assure that it meets the limits set forth in HNF-3 172, Rev. 0, ''Hanford Site Liquid Waste Acceptance Criteria, '' to permit transfer and disposal at the Effluent Treatment Facility (ETF) located at the 200 East Area.

Book Spent Nuclear Fuel  SNF  Project Cold Vacuum Drying  CVD  Facility Master Equipment List

Download or read book Spent Nuclear Fuel SNF Project Cold Vacuum Drying CVD Facility Master Equipment List written by and published by . This book was released on 1999 with total page 134 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document provides the master equipment list (MEL) for the Cold Vacuum Drying Facility (CVDF). The MEL was prepared to comply with DOE Standard 3024-98, Content of System Design Descriptions. The MEL was developed in conjunction with HNF-SD-SNF-SAR-002, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems and the CVDF System Design Descriptions (SDD). The MEL identifies the SSCs and their safety functions, the design criteria, codes and standards, and quality assurance requirements that are required for establishing the safety design basis of the SSCs. The MEL also includes operating parameters, manufacturer information, and references the procurement specifications for the SSCs. This MEL shall be updated, expanded, and revised in accordance with future phases of the CVDF SAR, the SDD's, and CVDF operations.

Book Cold Vacuum Drying  CVD  Facility Safety Class Instrumentation and Control System Design Description SYS 93 2

Download or read book Cold Vacuum Drying CVD Facility Safety Class Instrumentation and Control System Design Description SYS 93 2 written by and published by . This book was released on 1999 with total page 68 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document describes the Cold Vacuum Drying Facility (CVDF) Safety Class Instrumentation and Control system (SCIC). The SCIC provides safety functions and features to protect the environment, off-site and on-site personnel and equipment. The function of the SCIC is to provide automatic trip features, valve interlocks, alarms, indication and control for the cold vacuum drying process.

Book Cold Vacuum Drying  CVD  Facility Electrical System Captor and Dapper Study

Download or read book Cold Vacuum Drying CVD Facility Electrical System Captor and Dapper Study written by and published by . This book was released on 2000 with total page 289 pages. Available in PDF, EPUB and Kindle. Book excerpt: The objective of this report is to Validate and as-build the Load and Fault hand calculations performed by Meier Associates. Perform a protective device coordination study, not performed by Meier's, and furnish any recommendations, including recommended device settings. Perform Transient Motor Starting (TMS) analysis for the chillers and also the motors on the standby generator system. Indicate any design problems or NEC Code Violations, if found.

Book Cold Vacuum Drying  CVD  Electrical Equipment Hydrogen Hazard Protection

Download or read book Cold Vacuum Drying CVD Electrical Equipment Hydrogen Hazard Protection written by and published by . This book was released on 2000 with total page 14 pages. Available in PDF, EPUB and Kindle. Book excerpt: This document explains that with the use of a helium purge and adequate control, the systems attached to the MCO in the CVDF are not in a flammable environment. Effective safeguards against ventilation failure are provided which reduces the flammability hazard classification within the protected enclosure to Unclassified. Intrinsically safe components are not required for this system.

Book Thermal Analysis of Cold Vacuum Drying of Spent Nuclear Fuel

Download or read book Thermal Analysis of Cold Vacuum Drying of Spent Nuclear Fuel written by and published by . This book was released on 1998 with total page 414 pages. Available in PDF, EPUB and Kindle. Book excerpt: The thermal analysis examined transient thermal and chemical behavior of the Multi canister Overpack (MCO) container for a broad range of cases that represent the Cold Vacuum Drying (CVD) processes. The cases were defined to consider both normal and off-normal operations at the CVD Facility for an MCO with Mark IV N, Reactor spent fuel in four fuel baskets and one scrap basket. This analysis provides the basis for the MCO thermal behavior at the CVD Facility for its Phase 2 Safety Analysis Report (revision 4).

Book

    Book Details:
  • Author :
  • Publisher :
  • Release : 1983
  • ISBN :
  • Pages : 195 pages

Download or read book written by and published by . This book was released on 1983 with total page 195 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Castagnary

    Book Details:
  • Author :
  • Publisher :
  • Release : 198?
  • ISBN :
  • Pages : 1102 pages

Download or read book Castagnary written by and published by . This book was released on 198? with total page 1102 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Human Factors Engineering Report for the Cold Vacuum Drying Facility

Download or read book Human Factors Engineering Report for the Cold Vacuum Drying Facility written by and published by . This book was released on 1999 with total page 47 pages. Available in PDF, EPUB and Kindle. Book excerpt: The purpose of this report is to present the results and findings of the final Human Factors Engineering (HFE) technical analysis and evaluation of the Cold Vacuum Drying Facility (CVDF). Ergonomics issues are also addressed in this report, as appropriate. This report follows up and completes the preliminary work accomplished and reported by the Preliminary HFE Analysis report (SNF-2825, Spent Nuclear Fuel Project Cold Vacuum Drying Facility Human Factors Engineering Analysis: Results and Findings). This analysis avoids redundancy of effort except for ensuring that previously recommended HFE design changes have not affected other parts of the system. Changes in one part of the system may affect other parts of the system where those changes were not applied. The final HFE analysis and evaluation of the CVDF human-machine interactions (HMI) was expanded to include: the physical work environment, human-computer interface (HCI) including workstation and software, operator tasks, tools, maintainability, communications, staffing, training, and the overall ability of humans to accomplish their responsibilities, as appropriate. Key focal areas for this report are the process bay operations, process water conditioning (PWC) skid, tank room, and Central Control Room operations. These key areas contain the system safety-class components and are the foundation for the human factors design basis of the CVDF.