EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book An Improved Method for Measuring the Absolute DD Neutron Yield and Calibrating Neutron Time of flight Detectors in Inertial Confinement Fusion Experiments

Download or read book An Improved Method for Measuring the Absolute DD Neutron Yield and Calibrating Neutron Time of flight Detectors in Inertial Confinement Fusion Experiments written by Caleb Joseph Waugh and published by . This book was released on 2014 with total page 226 pages. Available in PDF, EPUB and Kindle. Book excerpt: Since the establishment of nuclear physics in the early 1900's and the development of the hydrogen bomb in the 1950's, inertial confinement fusion (ICF) has been an important field in physics. Funded largely though the U.S. National Nuclear Security Agency (NNSA), the Laboratory for Laser Energetics (LLE), Sandia National Laboratories (SNL) and Lawrence Livermore National Laboratory (LLNL) have advanced ICF as a platform for stockpile stewardship and weapons physics, but also have contributed to basic science in high energy density regimes and for pursuing fusion an energy source. One of the primary goals of the ICF research program is to produce a thermonuclear burn in an ICF capsule where the power balance of the reaction is net positive. This criterion is often referred to as ignition. One of the most common metrics for gauging progress towards ignition in an ICF implosion is the ITFX parameter (similar to the Lawson Criterion) and is primarily a function of the implosion areal density (pR) and fusion yield. An ITFX value greater than one indicates net energy production. In deuterium/tritium fuel mixtures the yield is determined by measuring the reactant 14.0 MeV neutrons. Subsequently, the ability to obtain highly accurate absolute neutron yield measurements is vital to determining the ITFX and hence progress toward ignition. Although ignition implosions all use deuterium/tritium fuel mixes, other capsule fuel mixes such as pure deuterium and deuterium/helium 3 are also used to improve understanding of capsule performance. At the LLE and LLNL, neutron time-of-flight (nTOF) detectors routinely measure the absolute neutron yield from laser-driven ICF implosions. Although originally calibrated through a series of cross-calibrations with indium and copper neutron activation systems, an alternative method has been developed for measuring the DDn yield that provides a more accurate calibration by directly calibrating nTOF in situ to CR-39 range filter (RF) proton detectors. A neutron yield can be inferred from the CR-39 RF proton measurement since the DD proton and DD neutron branching ratio is well characterized and close to unity. By obtaining highly accurate DDp yields from a series of exploding pusher campaigns on OMEGA, an excellent absolute DDn yield measurement was obtained and used to calibrate the 3m nTOF detector. Data obtained suggest the existing OMEGA nTOF calibration coefficient to be low by 9.0 1.5 % based on the inferred CR-39 DD neutron yield. In addition, comparison across multiple exploding pusher campaigns indicate that significant reduction in charged particle flux anisotropies can be achieved on shots where capsule bang time occurs significantly (on the order of 500ps) after the end of the laser pulse. This is important since the main source of error in the RF DDp yield measurement is due to particle flux anisotropies. Results indicate that the CR-39 RF/nTOF in situ calibration method can serve as a valuable platform for measuring the DDn yield from ICF implosions and for calibrating and reducing the uncertainty of calibration coefficients of nTOF detector systems on OMEGA and other larger facilities such as the National Ignition Facility (NIF).

Book A Method for in Situ Absolute DD Yield Calibration of Neutron Time of flight Detectors on OMEGA Using CR 39 based Proton Detectors

Download or read book A Method for in Situ Absolute DD Yield Calibration of Neutron Time of flight Detectors on OMEGA Using CR 39 based Proton Detectors written by and published by . This book was released on 2015 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Neutron time of flight (nTOF) detectors are used routinely to measure the absolute DD neutron yield at OMEGA. To check the DD yield calibration of these detectors, originally calibrated using indium activation systems, which in turn were cross-calibrated to NOVA nTOF detectors in the early 1990s, a direct in situ calibration method using CR-39 range filter proton detectors has been successfully developed. By measuring DD neutron and proton yields from a series of exploding pusher implosions at OMEGA, a yield calibration coefficient of 1.09 ± 0.02 (relative to the previous coefficient) was determined for the 3m nTOF detector. In addition, comparison of these and other shots indicates that significant reduction in charged particle flux anisotropies is achieved when bang time occurs significantly (on the order of 500 ps) after the trailing edge of the laser pulse. This is an important observation as the main source of the yield calibration error is due to particle anisotropies caused by field effects. The results indicate that the CR-39-nTOF in situ calibration method can serve as a valuable technique for calibrating and reducing the uncertainty in the DD absolute yield calibration of nTOF detector systems on OMEGA, the National Ignition Facility, and laser megajoule.

Book Tests and Calibration of the NIF Neutron Time of Flight Detectors

Download or read book Tests and Calibration of the NIF Neutron Time of Flight Detectors written by and published by . This book was released on 2008 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: The National Ignition Facility (NIF) Neutron Time of Flight (NTOF) diagnostic will measure neutron yield and ion temperature in all NIF campaigns in DD, DT, and THD* implosions. The NIF NTOF diagnostic is designed to measure neutron yield from 109 to 2 x 1019. The NTOF consists of several detectors of varying sensitivity located on the NIF at about 5 m and 20 m from the target. Production, testing, and calibration of the NIF NTOF detectors have begun at the Laboratory for Laser Energetics (LLE). Operational tests of the NTOF detectors were performed on several facilities including the OMEGA laser at LLE and the Titan laser at Lawrence Livermore National Laboratory (LLNL). Neutron calibrations were carried out on the OMEGA laser. Results of the NTOF detectors tests and calibration will be presented. *(D = deuterium, T = tritium, H = hydrogen).

Book Neutron Generators for Analytical Purposes

Download or read book Neutron Generators for Analytical Purposes written by International Atomic Energy Agency and published by IAEA Radiation Technology Repo. This book was released on 2012 with total page 145 pages. Available in PDF, EPUB and Kindle. Book excerpt: This publication addresses recent developments in neutron generator (NG) technology. It presents information on compact instruments with high neutron yield to be used for neutron activation analysis (NAA) and prompt gamma neutron activation analysis in combination with high count rate spectrometers. Traditional NGs have been shown to be effective for applications including borehole logging, homeland security, nuclear medicine and the on-line analysis of aluminium, coal and cement. Pulsed fast thermal neutron analysis, as well as tagged and timed neutron analysis, are additional techniques which can be applied using NG. Furthermore, NG can effectively be used for elemental analysis and is also effective for analysis of hidden materials by neutron radiography. Useful guidelines for developing NG based research laboratories are also provided in this publication.

Book Analysis of the Neutron Time of Flight Spectra from Inertial Confinement Fusion Experiments

Download or read book Analysis of the Neutron Time of Flight Spectra from Inertial Confinement Fusion Experiments written by and published by . This book was released on 2015 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: Neutron time-of-flight diagnostics have long been used to characterize the neutron spectrum produced by inertial confinement fusion experiments. The primary diagnostic goals are to extract the d+t → n+[alpha] (DT) and d+d→ n+3He (DD) neutron yields and peak widths, and the amount DT scattering relative to its unscattered yield, also known as the down-scatter ratio (DSR). These quantities are used to infer yield weighted plasma conditions, such as ion temperature (Tion) and cold fuel areal density. We report on novel methodologies used to determine neutron yield, apparent Tion, and DSR. These methods invoke a single temperature, static fluid model to describe the neutron peaks from DD and DT reactions and a spline description of the DT spectrum to determine the DSR. Both measurements are performed using a forward modeling technique that includes corrections for line-of-sight attenuation and impulse response of the detection system. Lastly, these methods produce typical uncertainties for DT Tion of 250 eV, 7% for DSR, and 9% for the DT neutron yield. For the DD values, the uncertainties are 290 eV for Tion and 10% for the neutron yield.

Book Physics Briefs

Download or read book Physics Briefs written by and published by . This book was released on 1992 with total page 820 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book On the Absolute Calibration of a DT Fusion Neutron Yield Diagnostic

Download or read book On the Absolute Calibration of a DT Fusion Neutron Yield Diagnostic written by and published by . This book was released on 2012 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Nuclear Science Information of Japan  Oral Presentation

Download or read book Nuclear Science Information of Japan Oral Presentation written by and published by . This book was released on 2002 with total page 718 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Summary of Neutron Measurement Methods

Download or read book Summary of Neutron Measurement Methods written by Herman Lunden Miller and published by . This book was released on 1962 with total page 28 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Magnetic Fusion Technology

Download or read book Magnetic Fusion Technology written by Thomas J. Dolan and published by Springer Science & Business Media. This book was released on 2014-02-10 with total page 816 pages. Available in PDF, EPUB and Kindle. Book excerpt: Magnetic Fusion Technology describes the technologies that are required for successful development of nuclear fusion power plants using strong magnetic fields. These technologies include: • magnet systems, • plasma heating systems, • control systems, • energy conversion systems, • advanced materials development, • vacuum systems, • cryogenic systems, • plasma diagnostics, • safety systems, and • power plant design studies. Magnetic Fusion Technology will be useful to students and to specialists working in energy research.

Book A Method for Intercalibrating of Neutron Sources with Different Spectra

Download or read book A Method for Intercalibrating of Neutron Sources with Different Spectra written by A. Wattenberg and published by . This book was released on 1950 with total page 12 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Neutron Source Strength Calibrations

Download or read book Neutron Source Strength Calibrations written by E. Dale McGarry and published by . This book was released on 1988 with total page 68 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Absolute Calibration of the Neutron Yield Measurement on JT 60 Upgrade

Download or read book Absolute Calibration of the Neutron Yield Measurement on JT 60 Upgrade written by C. W. (and others). Barnes and published by . This book was released on 1991 with total page 23 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Use of an On line Computer in Neutron Time of flight Measurements

Download or read book Use of an On line Computer in Neutron Time of flight Measurements written by H. T. Heaton and published by . This book was released on 1970 with total page 36 pages. Available in PDF, EPUB and Kindle. Book excerpt: The paper describes the on-line data handling system at the NBS Electron Linear Accelerator facility as it is used for measuring neutron total cross sections by time-of-flight techniques.(Author).

Book 14 MeV Neutrons

    Book Details:
  • Author : Vladivoj Valkovic
  • Publisher : CRC Press
  • Release : 2015-08-25
  • ISBN : 1482238012
  • Pages : 500 pages

Download or read book 14 MeV Neutrons written by Vladivoj Valkovic and published by CRC Press. This book was released on 2015-08-25 with total page 500 pages. Available in PDF, EPUB and Kindle. Book excerpt: Despite the often difficult and time-consuming effort of performing experiments with fast (14 MeV) neutrons, these neutrons can offer special insight into nucleus and other materials because of the absence of charge. 14 MeV Neutrons: Physics and Applications explores fast neutrons in basic science and applications to problems in medicine, the envir

Book The Chronotron Method of Measuring Neutron Time of Flight

Download or read book The Chronotron Method of Measuring Neutron Time of Flight written by Howard L. Ogushwitz and published by . This book was released on 1954 with total page 60 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Absolute Measurement of DT Neutron Yield on the National Ignition Facility

Download or read book Absolute Measurement of DT Neutron Yield on the National Ignition Facility written by and published by . This book was released on 2011 with total page 21 pages. Available in PDF, EPUB and Kindle. Book excerpt: