EBookClubs

Read Books & Download eBooks Full Online

EBookClubs

Read Books & Download eBooks Full Online

Book A High Intensity Gamma Radiation Survey Meter

Download or read book A High Intensity Gamma Radiation Survey Meter written by Jerome Henry King and published by Hassell Street Press. This book was released on 2021-09-09 with total page 194 pages. Available in PDF, EPUB and Kindle. Book excerpt: This work has been selected by scholars as being culturally important and is part of the knowledge base of civilization as we know it. This work is in the public domain in the United States of America, and possibly other nations. Within the United States, you may freely copy and distribute this work, as no entity (individual or corporate) has a copyright on the body of the work. Scholars believe, and we concur, that this work is important enough to be preserved, reproduced, and made generally available to the public. To ensure a quality reading experience, this work has been proofread and republished using a format that seamlessly blends the original graphical elements with text in an easy-to-read typeface. We appreciate your support of the preservation process, and thank you for being an important part of keeping this knowledge alive and relevant.

Book Measurement of High intensity Gamma Radiation

Download or read book Measurement of High intensity Gamma Radiation written by C. R. Hatcher and published by . This book was released on 1963 with total page 22 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book A Survey Meter for the Measurement of Intense Gamma Radiation

Download or read book A Survey Meter for the Measurement of Intense Gamma Radiation written by A. R. Jones and published by . This book was released on 1968 with total page 4 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Experiments with Radioactivity

Download or read book Experiments with Radioactivity written by and published by . This book was released on 1958 with total page 56 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Fast Transient High intensity Gamma ray Solid State Detectors

Download or read book Fast Transient High intensity Gamma ray Solid State Detectors written by William F. Lindsay and published by . This book was released on 1961 with total page 64 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Applications of a Small  Wide range Gamma Detector

Download or read book Applications of a Small Wide range Gamma Detector written by Alwyn C. Lapsley and published by . This book was released on 1955 with total page 18 pages. Available in PDF, EPUB and Kindle. Book excerpt: A small gamma probe operable between 100 mr/hr and 103 r/hr was built to measure gamma ray intensities near a large nonuniform source or in a large nonuniform field. The sensitive element, a thallium-activated sodium iodide crystal, is observed by a phototube. Four applications of the unit are described.

Book A High Range Gamma ray Survey Meter

Download or read book A High Range Gamma ray Survey Meter written by Atomic Energy of Canada Limited and published by . This book was released on 1964 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Effects of Gamma Radiation on Chemical Reactions

Download or read book Effects of Gamma Radiation on Chemical Reactions written by and published by . This book was released on 1952 with total page 16 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Portable Beta gamma Survey Meter

Download or read book Portable Beta gamma Survey Meter written by James O. Blackstone and published by . This book was released on 1962 with total page 16 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Development of a High intensity Solid state Gamma ray Dosimeter System

Download or read book Development of a High intensity Solid state Gamma ray Dosimeter System written by C. L. Fletcher and published by . This book was released on 1966 with total page 63 pages. Available in PDF, EPUB and Kindle. Book excerpt: Design, construction, and testing of an integrating gamma-ray dosimeter for high dose rates are discussed. The sensor is a silicon surface-barrier detector operating as a current device. The detector output current is integrated on a capacitor. When the voltage on the capacitor rises to a predetermined level corresponding to 10 rad-equivalent-air of gamma-ray dose, the capacitor is discharged and the instrument produces an output pulse to signal the event. The number of output pulses indicates integrated dose, and the pulse repetition rate indicates dose rate. The detector proper is cooled with a thermoelectric cooler to minimize and stabilize leakage current. The instrument is designed for operation in the dose-rate range of 10 to 100,000 rad-equivalent-air per second. The detector is constructed to make it function as a Bragg-Gray device over the gamma-ray energy range of 80 kev to 12 Mev. The detector is reasonably isotropic; cumulative errors due to all causes are less than plus or minus 30%. The electronics are insensitive to gamma-radiation transients for dose rates as high as 1,000,000 rad per second. Results of tests with radioactive sources, a fast-burst reactor, and bremsstrahlung pulses are given. (Author).

Book Scintillation Spectroscopy of Gamma Radiation

Download or read book Scintillation Spectroscopy of Gamma Radiation written by Stephen M. Shafroth and published by . This book was released on 1967 with total page 464 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Radiation Oncology Physics

Download or read book Radiation Oncology Physics written by International Atomic Energy Agency and published by IAEA. This book was released on 2005 with total page 704 pages. Available in PDF, EPUB and Kindle. Book excerpt: This publication is aimed at students and teachers involved in teaching programmes in field of medical radiation physics, and it covers the basic medical physics knowledge required in the form of a syllabus for modern radiation oncology. The information will be useful to those preparing for professional certification exams in radiation oncology, medical physics, dosimetry or radiotherapy technology.

Book Development of a Low Cost Gamma Radiation Survey Meter

Download or read book Development of a Low Cost Gamma Radiation Survey Meter written by L. G. Figular and published by . This book was released on 1964 with total page 127 pages. Available in PDF, EPUB and Kindle. Book excerpt: The report covers the investigation and development of a new low-cost gamma radiation survey meter with a range of 1 to 100 Roentgens per hour. A survey of existing gamma radiation detection transducers is presented with special emphasis on comparing newer semiconductor types with the Edison radiation detection type. Theory of operation and characteristics of the Edison radiation detector are given as well as results of preliminary gamma irradiation tests. Prototype design and testing is described and test results for the final prototype are given. A preliminary specification covering the new survey meter is presented to cover the design and testing requirements of a production instrument. Finally, recommendations are made which may result in improvement of the detection tube and reduce the cost of the meter still further. (Author).

Book Calculations and Measurements of the Energy dependent Response of a Shielded Gamma ray Detector

Download or read book Calculations and Measurements of the Energy dependent Response of a Shielded Gamma ray Detector written by and published by . This book was released on 1996 with total page 77 pages. Available in PDF, EPUB and Kindle. Book excerpt: Instruments designed to record high-intensity gamma-ray flashes must have fast time response, wide dynamic range, and good rejection of photon backgrounds at lower energies. In principle, plastic scintillators can easily provide the necessary time response and dynamic range; like other photon detectors, however, they must be carefully shielded to reduce their low-energy sensitivity. This shielding is often complicated by the need to use different optical sensors to cover the full dynamic range, which each sensor requiring a separate opening through the shielding. In this detector, a high-sensitivity photomultiplier tube handles low-intensity signals, and a silicon photodiode covers high intensities. These electronic components, particularly the diode, may also respond directly to incident radiation, so localized shielding must be provided. To reduce the detector's total mass, the scintillator and photodiode are enclosed in a relatively thick, tight-fitting inner shield, which is surrounded by a thin outer shield to reduce the leakage through any gaps. Although efficient, this arrangement demands careful design and testing. This report describes such an analysis, which uses Monte Carlo simulations to develop a comprehensive model of the detector at photon energies from threshold to above 10 MeV. Included are discussions of the fundamental responses of the unshielded silicon diode and plastic scintillator, explanations of the effectiveness of different shielding materials, studies of calibration sources, and comparisons with laboratory tests.

Book Portable Gamma Ray Survey Meter Using Silicon Amplifying Radiation Detectors

Download or read book Portable Gamma Ray Survey Meter Using Silicon Amplifying Radiation Detectors written by Atomic Energy of Canada Limited and published by . This book was released on 1969 with total page 5 pages. Available in PDF, EPUB and Kindle. Book excerpt:

Book Guidelines for Radioelement Mapping Using Gamma Ray Spectrometry Data

Download or read book Guidelines for Radioelement Mapping Using Gamma Ray Spectrometry Data written by International Atomic Energy Agency. Nuclear Fuel Cycle and Materials Section and published by . This book was released on 2003 with total page 173 pages. Available in PDF, EPUB and Kindle. Book excerpt: